| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L1 | Accepted-AOC aoc | |
| 2 | L2₹13.6 L+₹91,327.50 (7.19%)Rejected-Finance 00 SHOP NO 28 ABANTI BAI MARKET MAKRONIYA SAGAR MADHYA PRADESH 470004 | SAGAR | MADHYA PRADESH | 470004 | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹14.1 L+₹1.4 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹15.1 L+₹2.4 L (18.9%)Rejected-Finance NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L4 | Rejected-Finance Four lowest bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Saugor
GE Saugor
REPAIRS AND REPALCEMENT OF LT FEEDERS, PANELS, MCCBS, POLES AND MISC ALLIED WORKS UNDER GE SAUGOR
2021_MES_414186_1
GE/SGR/TOK-64 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Saugor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Saugor
₹30,000
Yes
2 Mar 2021
20 Jan 2021
20 Feb 2021
20 Jan 2021
18 Feb 2021
6 Feb 2021
60 days
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed .
All as per Srl item No1 above but depth exceeding 1.5 Mtr and not exc 3.00 Mtr complete all as specified and directed
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed .
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed .
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed .
Supplying and laying sub class'B' bricks laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and directed
Supplying, laying, connecting and testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 185 Sqmm 3.5core including taking down unserviceable LT UG cable any type/any size from trenches complete all as specified and directed
All as per Srl item No.7 above but size 150 sqmm 3.5 core -ditto-
All as per Srl item No.7 above but size 120 sqmm 3.5 core -ditto-
All as per Srl item No.7 above but size 95 sqmm 3.5 core -ditto-
Taking down and relaying of LT under ground cable of any type/any size complete all as specified and directed .
Laying only cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 25 to 70 Sqmm 3.5 core complete all as specified and directed . Note:- Cable shall be issued under Schedule 'B' as free for laying
All as per Srl item No 12 but Size 16 sqmm and 10 sqmm 4/2 core -ditto-
Supplying, laying and fixing in position galvanized iron pipe 80mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
Supplying, laying and fixing in position galvanized iron pipe 50mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
Supplying, laying and fixing in position galvanized iron pipe 40mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth) pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5mtr below ground level connected to galvanized earth wire 4mm by means of galvanised steel bolts nuts, check nuts and washer 15mm bore light graded GI Pipe and other end connected to earth test point as directed including 20mm bore light grade GI watering pipe, funnel with wire mesh, common salt and charcoal upto 15cm all around earth plate in alternate layers, PCC earth pit in PCC 1:3:6, type C-1, 50mm thick precast RCC slab as pit cover casting in PCC 1:2:4 type B-1 with 8mm dia deformed bars as reinforcement 15 cm C/C and suitable handle fo 10mm dia MS round bar including earth work and testing etc complete all as specified and shown on electrical plate No-5 of MES SSR Part-I
All as per Srl item No 17 above but using galvanised iron strip 25mmx4mm as earthing lead -ditto-
M&L for earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of 25x4mm galvanised iron strip complete all as specified and directed
Supply and erection of steel tubular poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 metre long including taking down the old unserviceable LT PCC/steel tubular pole complete all as specified and directed .
Supply and erection of pre-stressed concrete pole in vertical position 9 metre long 102mm X 172mm at top and 102mm X 279mm at bottom, Class-10 confirming to IS-1678 and including marking alternate white and black strips 30cm height with two coats of synthetic enamel paint over a coat of primer including taking down the old unserviceable LT PCC/steel tubular pole complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregates) as in foundations for LT pole complete all as specified and directed .
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) for coping of pole using extra cement for smooth finish including necessary form work complete all as specified and directed .
M&L for PCC 1:4:8, type D-2 (using 40mm grade stone aggregates) as in bed for pole in foundation filling and mass concrete filling complete all as specified and directed .
S&F in repairs aluminium conductors steel reinforced (ACSR conforming to IS : 398) Part-II) -1976 for HT/LT over head lines on PCC/ steel/rail poles including Aluminium binding wire complete all as specified of exixting size.
S&F in replacement GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire for LT/HT OH conductor including dismantling of earth wire conductor service feeder or distributor span complete all as specified and directed .
S&F stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 16 mm dia including loop insulator suitable for 1.1 KV (size 65x90 mm) with clearance of hole 16 mm and MS stay plate size 230 x 230 x 6mm, stay clamps etc including dismantling exisitng stay assembly complete all as specified and directed.
M&L for galvanised stay strand 7/3.15 mm or 7/4.00 mm size with minimum tensile strength of 700 N/ Sqmm and conforming to IS : 2141-1979 complete all as specified & directed.
S&F in replacement pin type, vitreous, white, brown or green insulator including Galvanised Mild Steel spindle, two Galvanised iron washers and one GI nut 100 mm height , 65 mm dia suitable for 1100 Volt working pressure grade (LT) complete all as specified and directed
S&F in replacement shackle type porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel straps, washers, suitable bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 volts working pressure grade complete all as specified and directed .
S&F danger notice plate 1.6 mm thick mild steel sheet, viterous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT of size 20x15 cm complete all as specified and directed .
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel Sections including nuts, bolts, washers, welding nuts, bolts, washers welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed .
M&L for Anti-Climbing device; Spikes type fabricated out of M.S.bars (round, Square and Flat) including nuts, bolts,washers and welding in two halves made to shape to suit the cross section of pole complete all as specified and directed .
Checking of G8 plus power controller/thyristor based APFC panel of any size and any capacity with minimum requirement of material like relay, contactor, modules all as per site requirement complete all as directed. (Note : Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement, entire APFC panel should be capable of capable of improvement of PF upto 0.995 on the average of monthly consumption, at the different loads of Pump set and during the off load entire installation even at No Load.
S&F in replacement of complete unit of capacitor metalized poly propylene (MPP-H)/ NSL heavy duty for 3 phase 440 V & 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity complete all as specified and as directed Make - NEPTUNE/ SCHNEIDER// L&T. Suitable for existing capacitor bank at site.
All as per Srl item No. 35 above but of capacity 10 KVAR complete all as specified and as directed by Engineer-in charge.
All as per Srl item No. 35 above but of capacity 12.5 KVAR complete all as specified and as directed by Engineer-in charge.
All as per Srl item No. 35 above but of capacity 25 KVAR complete all as specified and as directed by Engineer-in charge.
Supply, fixing, connecting and testing of power factor relay RM-8 for APFC panel of any size and any capacity including adjusting and setting up the power factor till 0.99 complete all as specified and directed .
S&F in replacement digital volt meter for thyristor panel suitable for existing panel complete all as specified and directed .
S&F in replacement discharge reactor for thyristor panel suitable for existing panel complete all as specified and directed .
S&F in replacement thyristor switching module PS 12.5 KVAR for thyristor panel suitable for existing panel complete all as specified and directed .
S&F in replacement thyristor switching module PS 25 KVAR for thyristor panel suitable for existing panel complete all as specified and directed .
S&F in replacement thyristor switching module PS 50 KVAR for thyristor panel suitable for existing panel complete all as specified and directed .
S&F in replacement capacitor heavy duty MLL 12.5 KVAR complete all as specified and directed and directed
S&F in replacement capacitor heavy duty MLL 25 KVAR complete all as specified and directed and directed
M & L for repairing and servicing two/four pole structures comprising of following works :- (a) Dismantling the ACSR jumper connection from Air break Gang operated drop out fuse end lightening arrestors etc from the two/four poles structures, replacing the complete jumpers in to new with ACSR conductors including connecting with suitable thimbles connections/binding/PG clamps and providing monoplast compound over binding/thimble connections b) Removing the complete rusted bolts, nuts and washers and replacing with new bolts, nuts and washers (c) Disconnecting the AB switch knives cleaning and servicing by lubricating the moving parts terminals with petroleum jelly. (d) Cleaning the exposed surfaces of two/four pole structure complete and painting with two coats of synthetic enamel aluminium paint all as specified and directed by Engr-in-Charge
S&F in replacement AB switch copper knives with arc rod suitable for 11KV GOD complete all as specified and directed .
S&F in replacement AB switch female contact suitable for 11KV GOD complete all as specified and directed .
S&F in replacement AB switch Jumper carries suitable for 11KV GOD complete all as specified and directed .
S&F in replacement AB switch copper fluxible strip suitable for 11KV GOD complete all as specified and directed .
S&F in replacement stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 2.5 Sqmm 2 core complete all as specified and directed .
S&F in replacement stranded aluminium conductor flat twin core PVC insulated unsheathed 1100V 1.5 Sqmm 2 core complete all as specified and directed .
S&F framed work as in doors or gates of angle made out of FE 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed .
M&L including fabrication of existing panel cover with hing, nut and bolt duly painted with two coats painting of existing colour complete all as specified and directed
M&L for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and remove to a distance not exc 50 mtr all as directed.
Cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which or growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance not less than 1.5 mtr from ACSR conductor/ poles/ structure and taking down the same on the ground carefully avoiding the damage of and removing to a distance including stretching of conductor as required where directed by Engr - in -charge. Note :- Tree cutting will be maintain for periodisity for three months depending upon the grougth of three branches.
S&F in replacement MCCB 4 pole 415 volt adjustable thermal setting of 250 Amps with breaking capacity 25 KA complete all as specified and directed
S&F in replacement MCCB 4 pole 415 volt adjustable thermal setting of 200 Amps with breaking capacity 25 KA complete all as specified and directed
S&F in replacement MCCB 4 pole 415 volt adjustable thermal setting of 160 Amps with breaking capacity 25 KA complete all as specified and directed
S&F in replacement MCCB 4 pole 415 volt adjustable thermal setting of 125 Amps with breaking capacity 16 KA complete all as specified and directed
S&F in replacement MCCB 4 pole 415 volt adjustable thermal setting of 100 Amps with breaking capacity 16 KA complete all as specified and directed
M&L for painting of steel srtuctures in Main Receiving Station of MES Saugor including all cross arms, clamps etc with 2 coats of aluminium paint and including preparation of surfaces and painting upto the height upto 9 m with 2 coats of synthetic enameled paint and making alternate black and white strips 30 cm height (total 05 Nos) complete all as specified and directed
M&L for painting of steel srtuctures/tubular/ rail pole (Cross arms, clamps etc) with 2 coats of aluminium paints and including preparation of old steel surfaces and painting upto the height upto 9 m pole with 2 coats of synthetic enameled paint and making colour bands and rewriting the pole number comlete all as specified and directed
S&F in replacement double drum winch of safe working load 350 Kg suitable for 16m height High mast light of existing make (Bajaj) comlete all as specified and directed
SHRI RAM ELECTRICALS ENTERPRISES
shivansh traders
Veer Brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .