Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L1 | Accepted-AOC Accept | |
| 2 | L2₹56.9 L+₹7.0 L (14.1%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹57.0 L+₹7.1 L (14.3%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹58.4 L+₹8.5 L (17.1%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹59.0 L+₹9.1 L (18.3%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | A. R. ELECTRICALS L2 | PTech Engineers L1 | M/s Pooja Enterprises L3 | Tropical Refrigeration L4 | SKY GROUP L7 | M/S AMBER PAVER PRODUCTS L8 | M/s K Moorthi L6 | ANITA VARMA ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, fixing and testing in replacement of conventional manual call point 24V resettable type, each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion. Complete all as specified and directed by the Engineer-in-Charge. | 10 | Each | 10,000 ₹1,00,000 | 8,870 ₹88,700 | 10,003 ₹1,00,030 | 9,540 ₹95,400 | 9,650 ₹96,500 | 9,500 ₹95,000 | 10,490 ₹1,04,900 | 8,500 ₹85,000 Lowest |
| 2.00 | Repairing and testing of existing unserviceable and manual call point/ fire smoke detector/fire sensor/alarm including opening, soldering of circuits, cleaning, replacement of glass, testing and painting complete all as specified and directed by Engr-in-Charge. | 32 | Each | 1,250 ₹40,000 | 900 ₹28,800 Lowest | 1,290 ₹41,280 | 1,150 ₹36,800 | 1,180 ₹37,760 | 1,350 ₹43,200 | 1,340 ₹42,880 | 1,324 ₹42,368 |
| 3.00 | Supply fixing and testing in replacement of loop powered sounder strobe 24V. Dual tone hooter shall be of electronic type and shall give discontinuous/ intermittent audible alaram. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion and complete all as specified and directed by the Engineer-in-Charge. | 6 | Each | 15,500 ₹93,000 | 13,860 ₹83,160 Lowest | 15,560 ₹93,360 | 16,000 ₹96,000 | 16,520 ₹99,120 | 16,681 ₹1,00,086 | 16,570 ₹99,420 | 16,359 ₹98,154 |
| 4.00 | Dismantling the existing loop sounder by disconnecting device by movable ladder, dismantling cap & sensor board, cleaning the parts using CRC solution and check the control wiring circuit the PCB board , communication panel, device controlled by a programme, device sound & fire red flash light indication while fire activate and re addressing & re installation work complete all as specified and directed by Engr-in Charge. | 15 | Each Job | 1,710 ₹25,650 | 1,350 ₹20,250 Lowest | 1,720 ₹25,800 | 1,950 ₹29,250 | 2,100 ₹31,500 | 2,059 ₹30,885 | 2,050 ₹30,750 | 2,019 ₹30,285 |
| 5.00 | Programming the main fire alarm panel, detecting the device activating the sounder according to the device, checking the communication between the all the device, fire alarm and main panel using ladder, making main fire alarm to normal display without any fault complete all as specified and directed by the Engineer-in-Charge. | 2 | Each Job | 73,900 ₹1,47,800 | 71,340 ₹1,42,680 Lowest | 73,920 ₹1,47,840 | 81,880 ₹1,63,760 | 82,500 ₹1,65,000 | 87,958 ₹1,75,916 | 87,370 ₹1,74,740 | 86,258 ₹1,72,516 |
| 6.00 | S & F in replacement of Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and as directed. | 1 | Each | 1,75,450 ₹1,75,450 | 1,62,613 ₹1,62,613 Lowest | 1,75,490 ₹1,75,490 | 1,70,220 ₹1,70,220 | 1,71,200 ₹1,71,200 | 1,91,438 ₹1,91,438 | 1,90,160 ₹1,90,160 | 1,87,738 ₹1,87,738 |
| 7.00 | S & F in repair of Beam Master detector with Transmitter and receiver complete all specifed and directed. | 1 | Each | 89,750 ₹89,750 | 83,155 ₹83,155 Lowest | 89,765 ₹89,765 | 94,650 ₹94,650 | 95,620 ₹95,620 | 1,00,555 ₹1,00,555 | 99,880 ₹99,880 | 98,611 ₹98,611 |
| 8.00 | S & F in repair of Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range complete all as specified and as directed. | 4 | Each | 17,100 ₹68,400 | 14,785 ₹59,140 Lowest | 17,105 ₹68,420 | 15,775 ₹63,100 | 15,820 ₹63,280 | 17,876 ₹71,504 | 17,760 ₹71,040 | 17,531 ₹70,124 |
| 9.00 | S & F in repair of Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and as directed by engr-in-charge. | 4 | Each | 6,000 ₹24,000 | 5,265 ₹21,060 Lowest | 6,020 ₹24,080 | 5,900 ₹23,600 | 6,200 ₹24,800 | 6,561 ₹26,244 | 6,520 ₹26,080 | 6,434 ₹25,736 |
| 10.00 | Material & labour wiring for circuit / submain wiring along with earth wire with the cable FR LSH, PVC insulated, un sheathed, copper conductor, multistranded, 1100 volts grade single core cables drawn through and including ERW steel conduit and conduit accessories surface / concealed in walls all as specified of size 2 x 1.5 Sq mm + 1 x 1.5 Sq mm for Smoke / fire detectors. Complete all as directed by Engr-in-Charge. | 60 | RM | 400 ₹24,000 | 320 ₹19,200 Lowest | 410 ₹24,600 | 370 ₹22,200 | 398 ₹23,880 | 414 ₹24,840 | 410 ₹24,600 | 406 ₹24,360 |
Tender Value
₹49.4 L
EMD Value
₹98,840
Closing Date
15 Mar 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
8540- RPAIR/MAINT OF DG SETS AND ITS CONNECTED WORKS AT NTS, MARCOS, NCN AND DCTF, CHOULDHARI, PROTHRAPUR, PORT MOUNT, BROOKSHABAD AND REPAIR/MAINT OF FIRE FIGHTING AND ITS CONNECTED EQUIPMENTS AT INS UTKROSH UNDER AGE E/M-II OF GE MINNIEBAY,
2025_MES_698623_1
8540/E8
Open Tender
Civil Works
Item Rate
270 days
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE, Minniebay
₹98,840
Yes
23 Aug 2025
20 Feb 2025
17 Mar 2025
20 Feb 2025
15 Mar 2025
8 Mar 2025
Amount
Supply, fixing and testing in replacement of conventional manual call point 24V resettable type, each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion. Complete all as specified and directed by the Engineer-in-Charge.
Repairing and testing of existing unserviceable and manual call point/ fire smoke detector/fire sensor/alarm including opening, soldering of circuits, cleaning, replacement of glass, testing and painting complete all as specified and directed by Engr-in-Charge.
Supply fixing and testing in replacement of loop powered sounder strobe 24V. Dual tone hooter shall be of electronic type and shall give discontinuous/ intermittent audible alaram. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion and complete all as specified and directed by the Engineer-in-Charge.
Dismantling the existing loop sounder by disconnecting device by movable ladder, dismantling cap & sensor board, cleaning the parts using CRC solution and check the control wiring circuit the PCB board , communication panel, device controlled by a programme, device sound & fire red flash light indication while fire activate and re addressing & re installation work complete all as specified and directed by Engr-in Charge.
Programming the main fire alarm panel, detecting the device activating the sounder according to the device, checking the communication between the all the device, fire alarm and main panel using ladder, making main fire alarm to normal display without any fault complete all as specified and directed by the Engineer-in-Charge.
S & F in replacement of Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and as directed.
S & F in repair of Beam Master detector with Transmitter and receiver complete all specifed and directed.
S & F in repair of Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtrs range complete all as specified and as directed.
S & F in repair of Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 complete all as specified and as directed by engr-in-charge.
Material & labour wiring for circuit / submain wiring along with earth wire with the cable FR LSH, PVC insulated, un sheathed, copper conductor, multistranded, 1100 volts grade single core cables drawn through and including ERW steel conduit and conduit accessories surface / concealed in walls all as specified of size 2 x 1.5 Sq mm + 1 x 1.5 Sq mm for Smoke / fire detectors. Complete all as directed by Engr-in-Charge.
Supply,Installation and testing of fire alaram panel of existig Zone conventional type made out of CRCA sheet with powder coated finish of IP50 red colour suitable for operate on primary power 120-220VAC and stand by power 24 V DC , wall/celing mounted completed all as specified and as directed by Engr-in-Charge.
M&L for disconnecting/ removal of corroded MS sheet 3mm thick from fire fighting boxes and supply and fabricate 3mm thick CRCA sheet including necessary door hinges, door knobs, door locks, aldrops, over drops, door beading, rubber washers angles iron channel, clamps etc including applying 2 coats of synthetic enamel PO red paint over a coat of zinc chrome primer and fixing of 4mm thick transparent glass on the door as per existing complete all as directed by Engineer-in-Charge. Note:(a).The rate quoted includes connected welding works/ gas cutting works along with all hardware/ miscellaneous items. (b) Transparent glass sheet and lock & Key arrangement system will be measured separately.
Supply and fixing transparent plain glass 4mm to 5mm thick as per site requirement and existing specification. Complete all as specified and directed by Engr-in-Charge.
Supply and fix lock and key arrangement for fire hydrant chamber as per existing with two nos of keys for each lock all as specified and directed by Engr-in-Charge.
Supply and fixing rubber hose pipe 30 mtr,20mm inner dia, thermo plastic, working pressure 10kg/sqcm confirming to IS-12585 braided for high pressure complete all as specified and directed by Engr-in-Charge.
Supply and fixing fix Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short suitable for 20mm bore hose pipe with handle as per existing complete all as specified and directed by Engr-in-Charge.
Repair of hose pipe reel drum suitable for 30 mtrs, 20 mm dia rubber hose pipe working pressure 10 Kg/Sqcm complete all as specified and directed by Engr-in-Charge.
Supply and fixing ISI marked RRL (Rainforced Rubber Lined) fire hose pipe 15 meter long with male and female couping gun metal 63mm instantaneous inlet with 15mm bore nozzle short complete all as specified and directed by Engr-in-Charge.
Supply and fixing fix gun metal fire hose reel nozzle suitable for 63mm bore hose pipe with as per existing complete all as specified and directed by Engr-in-Charge.
Supply and fixing single headed outlet hydrant valve suitable for 80 mm flanged end having 65mm outlet with lock pin wheel including nut, bolt, washer, gasket complete all as specified and directed by Engr-in-Charge.
Repair single/double headed outlet hydrant valve 80 mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engr-in-Charge.
Providing & fixing in repair 80mm dia bourden type, stainless steel dial type pressure Gauge (0 - 14 Kg) range, 4" BSP bottom entry on pump delivery line complete with ball valve. Complete all as specified and as directed by Engr-in-Charge.
Supply and fixing hose reel drum with handle suitable for hold 30 mtr hose pipe complete all as specified and as directed by Engr-in-Charge.
Supply,Installation and testing of fire alaram panel in repair of existing Zone conventional type made out of CRCA sheet with powder coated finish of IP50 red colour suitable for operate on primary power 120-220VAC and stand by power 24 V DC , wall/celing mounted completed all as specified and as directed by Engr-in-Charge.Make EDWARD EST3X
S& F in repair of Network card suitable for EST3X complete all as specified and directed by Engr-in-Charge.Make: EST
M&L for repair and servicing of repeater panel suitable for EST 3X by complete opening thorough checking of PCB and its connected component, cleaning with CTC liquid, reassembling as and fixing back complete all as specified and directed by Engr-in-Charge
S&F in repair of repeater panel Control Card suitable for EST3X repeater complete all as specified and directed by Engr-in-Charge.Make: EST
M&L for install ,Commissioning,testing of Two loop panel complete all as specified and directed by Engr-in-Charge.
Supply and fixing battery 7AH, 12 Volts maintenance free as per existing make and specification complete all as specified and directed by Engr-in-Charge.
Material and labour for cutting existing MS pipe of bore 80mm to 150mm size and jointing with proper welding and testing of all fittings complete with all welding/threading works and jointing material laid in trenches/ on surface / slopes/ pillars/ culverts includind necessary earth work etc. complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of cast iron sluice valve of size 150 mm (PN 1.6) (ISI Marked) with iron wheel head, both end flanged, stainless steel spindle, non rising type complete with neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of cast iron non return sluice valve, conforming to IS-5312, suitable for 150 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-Charge.
Material and labour of cross arms ,bracings,supports,clamp and back plate fabicated from structural steel sections,including nut and bolts, washers welding bend or cold or hot,drilling holes for bolt in any shape or size indicated or direcected and inclusive of one primer coat,one under coat and one finishing coat all complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing ERW MS pipe class 'B' pipe 150 mm bore having wall thickness 6mm with permissible tolerance + 10%, pipe shall be confirming to IS-3589, IS marked and steel grade of Fe-410 along with joints (As per site requirements) and taking down of old unserviciable pipe. laid in trenches/along road/on surfaces/slopes/pillars/culverts/causeways etc. complete all as specified and directed by Engr-in-Charge. Note:- (i) Jointing of pipe line will be done through flanging including nut bolts, washers, flanges etc or circular welding as per site requirment and directed by Engr-in-Charge. (ii) Excavation and earth work will be measured and paid separately.
All as per serial item No 34.00 here-in-before but of size 80 mm bore.
Supply and fixing in replacement of butterfly valve of size 150 mm (PN 1.6) (ISI Marked) gtype complete with neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-Charge.
Repair to old sluice valve of sizes 80 to 150mm for check nut, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing complete all as directed complete all as specified and directed by Engr-in-Charge.
Repair to old non return valve of sizes 80 to 150mm for check nut, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of non return valve including fixing & testing complete all as specified and directed by Engr-in-Charge.
Disconnecting electric connection of 10 HP to 40 HP motor, removing the unserviciable motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair & re-assembling the same. Complete all as directed by Engineer-in-Charge. Note: (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed by Engr-in-Charge.
Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 10 HP to 40 HP with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time. Note:- Cost of labour for winding deemed to be included in the rate quoted. Make : Atlas/Devi Dayal or equivalent make approved by GE.
Material and labour for scrapping of existing paint on fire fighting Pipe lines, fittings, motors, pumps, cabinet boxes, valve chamber covers, fire brigades and other miscellaneous items associated to the complete fire fighting system in buildings up to (G+6 floors) and applying two coats red colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity 10 HP all as specified and directed by Engineer-in-charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A.
Supply only parts in repair for single/multistage pumps of capacity 10 HP to 40 HP as per manufacturer's composition of existing make of pump as below all as specified and directed by Engr-in-Charge :-
Pump impeller made out of stainless steel or as per existing specification.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling or as per existing at site.
Gland cup.
Shaft sleeves.
Welding remelting and turning finishing cutting of key ways in respect of pump shaft.
Bearing housing.
Supply and fixing Led Indicators as per existing make and specification complete all as specfied and as directed by Engr-in-Charge.
Supply and fixing push buttons as per existing make and specification complete all as specfied and as directed by Engr-in-Charge.
Supply and fixing MCB 4 pole 6-32A as per existing make and specification complete all as specfied and as directed by Engr-in-Charge.
Supply and fixing MCB SP 6-32A as per existing make and specification complete all as specfied and as directed by Engr-in-Charge.
Supply,installation of antivibratings pads of size 4 inch suitable for 10 HP pump grouted I with nut and bolts in PCC complete all as specfied and as directed by Engr-in-Charge.
S & Fixing including testing in replacement of the lead acid battery 12 V DC 100 AH including the initial charge, terminals connector make : Exide / SF / Lucas
Supply and pouring coolant for radiator of DG set of any capacity of DG set make: Cummins / Kirloskar / Greaves
Supply and pouring engine oil for DG set grade oil 20W40 complete all as directed Make : I O C Servo
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 25x4mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit and test point complete.
M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by representative / authorised Service Engineer of OEM of the DG Set including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed. Note: The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.
All as per item No.55.00 above DG set of capacity 500 KVA
All as per item No.55.00 above DG set of capacity 320 KVA
All as per item No.55.00 above but for DG set of capacity 250 KVA
All as per item No.55.00 above but for DG set of capacity 200 KVA
All as per item No.55.00 above but for DG set of capacity 125 KVA
All as per item No.55.00 above but for DG set of capacity 100 KVA
All as per item No.55.00 above but for DG set of capacity 82.5 KVA
All as per item No.55.00 above but for DG set of capacity 62.5 KVA
All as per item No.55.00 above but for DG set of capacity 20 / 25 KVA Note: For Item sl. no. 55.01 to 55.09 supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item
M & L for supply, fixing of Air filter of 500 KVA DG set all as specified and directed by Engineer-in-charge make : Cummins
M & L for supply, fixing of Air filter of 320 KVA DG set all as specified and directed by Engineer-in-charge make : Cummins
M & L for supply , fixing of Air filter of 250 KVA / 200 KVA DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves
M & L for supply , fixing of Air filter of 125 KVA DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves/Kirloskar
M & L for supply , fixing of Air filter of 20/25/62.5/82.5/100 DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves
S & fixing in repair water pump assly in 500 /250/200 KVA DG set make Cummins / Kirloskar
S & fixing in repair water pump assly in 20 / 62.5 / 82.5 / 125 / 160 KVA DG set make Cummins / Kirloskar / Greaves
Supply only engine oil for DG set grade oil 20W40 complete all as directed Make : I O C Servo
Supply only engine oil for DG set grade oil 15W40 complete all as directed Make : I O C Servo
Supply only coolant for radiator of DG set of any capacity of DG set make: Cummins / Kirloskar / Greaves
Supply only distilled water for radiator and batteries of DG set
M & L for repair and reconditioning the starting motor 12 V DC system including taking out the defective starter from 20 KVA -160 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, bushes, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning the starting motor 24 V DC system of kirloskar make including taking out the defective starter from 500 KVA / 320 / 250/ 200 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, bushes, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
Dismantling the battery charge alternator 12 V DC from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 20/ 62.5 / 82.5 KVA / 125 KVA DG set all as specified and directed by Engineer-in-charge
Dismantling the battery charge alternator 24 V DC from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 200/ 250 / 320 / 500 KVA DG set all as specified and directed by Engineer-in-charge
M & L for repair and servicing in PT fuel pump of 200 / 250 / 320 / 500 KVA DG set by taking out the defective defective fuel pump, renewing the worn out parts, seals, o rings, governor weight carriers, carryingout repair and calibration of PT fuel pump and fixing back in the engine and testing on load all as directed by Engineer-in-Charge
M & L for supply, fixing in fuel pump of 20 /62.5/82.5/125/160 KVA DG set by taking out the defective defective fuel pump, renewing the worn out parts, seals, o rings, governor weight carriers, carryingout repair and calibration of fuel pump and fixing back in the engine and testing on load all as directed by Engineer-in-Charge
M & L for supply, installation and commissioning of AVR in 20 /25 /62.5/82.5/125/160 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge make Kirloskar / Altex / Senlec
M & L for supply, installation and commissioning of AVR in 200/250/320 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge make Kirloskar / Altex / Senlec
M & L for supply, fixing AVR for excitation under Cummins AUX 105 of 500 KVA by removing the defective unit from alternator and fixing back new and connecting with system and commisioning and testing complete make: Cummins/Senlec
S & Fixing the lead acid battery 12 V DC 180 AH including the initial charge, terminals connector make : Exide / SF / Lucas
S & Fixing the lead acid battery 12 V DC 150 AH including the initial charge, terminals connector make : Exide / SF / Lucas
S & Fixing the lead acid battery 12 V DC 130 AH including the initial charge, terminals connector make : Exide / SF / Lucas
M & L for supply and fixing engine fuel hose assly along connector for 200 / 250/ 320/ 500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply and fixing engine Lube oil hose assly along adaptor for 200 /250/320/500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply and fixing engine coolant hose and clamp for 200/250/320/500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply, fixing in repair coil electrical in STC control valve in 500 KVA DG set as specified and directed by Engineer-in-charge
M & L for supply fixing in repairs magnetic pick up suitable for 20 /62.5 /82.5 /125 /200 / 250 / 320 / 500 KVA DG set by taking out the defective unit from engine , replacing the same and adjusting the gap setting. Connecting in the circuit all as specified as directed by Engineer-in-charge
S & Fixing in repairs Low lub oil pressure safety control in DG set and connecting with DG set system of 20 KVA to 500 KVA all as directed by Engineer-in-Charge
S & Fixing in repairs High water temperature trip safety 20 KVA to 500 KVA DG set and connecting with DG set system all as specifiied and directed by Engineer-in-charge
M & L for supply, fixing fuel oil pressure sensor in 500 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing lub oil pressure sensor in 200 /250 / 320 / 500 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing lub oil pressure sensor in 30 KVA to 125 KVA DG set all as directed by Engineer-in-Charge
S & Fixing in repair fan belt suitable for 500 KVA DG set all as specified and directed by Engineer-in-charge
S & Fixing in repair shutdown valve in 200 / 250 / 500 KVA DG set as specified and directed by Engineer-in-charge
S & fixing in dynamo belt in 20 KVA to 500 KVA and testing as specified and directed by Engineer-in-charge
S & Fixing in repair and rewinding the excitor stator field assembly of 200 / 250 / 500 KVA by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of bectol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing all as specified and directed by Engineer-in-charge
M & L for taking down unserviceable starting motor from the engine 62.5/82.5/100/125/160 KVA and supply and fixing starter assly and connecting with circuit and testing complete all as directed.
Taking out ACB breaker for repair and servicing by disconnecting and dismantling the ACB breaker rating 2000 Amps / 1000 Amps / 800 Amps make L&T by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 230 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge.
Note item no.94.00 The spare required for repairs / replacement will be measured and paid seperately
Supply only shunt release coil 240 V AC all as per sample and as specified
Supply only Closing coil 240 V AC all as per sample and as specified
Supply only undervoltage coil 240 V AC all as per sample and as specified
Supply only spring charging motor suitable for fixing in ACB of make L&T C Series operated in 240 V AC supply all as specified
Supply and fixing in repairs phase indicator lamps R, Y, B LED type
M & L for fixing in repair and commissioning battery charging alternator 12V / 24 V DC in DG sets all as directed .
M & L for taking down unserviceable solenoid switch from starter motor of 200 / 250 / 320 / 500 KVA, opening and removing bunrt defective parts, replacing by new solenoid switch and connecting with contacts and testing complete all as directed by Engineer-in-charge
M & L for replacement of battery lead 1.25 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 75 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end all as directed.
M & L for supply and fixing of Engine display control (Microprocessor based type) by taking out the defective unit from 30 KVA to 320 KVA capacity DG set complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge Make: Cummins / Kirloskar / Deep sea
Painting of diesel generator canophy capacity 30 KVA to 100 KVA by applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting after preparation of old paint surface including stickering of MES no., DG set details, etc all as specified and directed by Engineer-in-charge
S & Fixing rotating rectifier kit diode set ( 6 nos ) suitable for 500 / 320 KVA DG set all as specified and directed by Engineer-in-charge
S & Fixing rotating rectifier kit diode set ( 6 nos ) suitable for 30 KVA to 250 KVA DG set all as specified and directed by Engineer-in-charge
S & Fixing in repair fan belt suitable for 30 KVA to 125 KVA DG set all as specified and directed by Engineer-in-charge
S & Fixing in repair fan belt suitable for 320 KVA / 250 KVA / 200 KVA DG set all as specified and directed by Engineer-in-charge
S & Fixing in repairs solenoid on / off switch for FIP fuel pump of DG set capacity 30 KVA to 125 KVA KVA DG set suitable for kirloskar make engine and cooecting with circuit system all as directed by Engineer-in-Charge
S & Fixing in repairs battery charger automatic SMPS type 220 V AC input and 24/12 V 10 Amps output with auto cut off, floating, indicating maters, lamps, connectig in the exisitng circuit and testing all as specified and directed by Engineer-in-charge
Material and labour for carrying out repairs in the Electronic Governor Control (EGC) in 30 KVA to 250 KVA DG set by taking out the defective parts from DG set, fixing new controller in the engine and connecting with circuits, starting and testing the DG set on load complete all as specified and directed .
S&Fixing in repairs of start and stop control PCB control unit suitable for 30 /62.5 / 82.5 /125 KVA DG set make: Cummins / Kirloskar
M & L for supply, installation and commissioning of Actuator in 500 KVA / 200 KVA DG set by taking out the defective Actuator from enginet, fixing the new Actuator and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge make: Cummins / Kirloskar
S&Fixing in repairs of low coolant water level sensor suitable for 500 KVA DG set make: Cummins
M & L for thorough checking and cleaning of chocked radiator of 500 KVA by applying suitable chemical liquid, cleaning detergents by taking care of tubes and fins, opening fan guards, removing deposited sludges, oil wet and carbons from fins, refixing all removed items back and starting and testing of DG set on load all as specified and directed by Engineer-in-charge
S & fixing alternator terminal connector in 200/250/320 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal and tightening and testing at NTS power house all as specified and directed by Engineer-in-charge.
S & fixing alternator terminal connector in 30 KVA to 160 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal and tightening and testing at NTS power house all as specified and directed by Engineer-in-charge.
M & L for replacement of DG Set door Hinges & accessories,for 20 / 62.5/82.5 /250 / 320 KVA all as specified & directed .
S&F in Anti Vibration Mounting bracket in 62.5 KVA to 250 KVA DG set for Engine mounting foot including dismantling and taking out from mounting with using chain pully and testing complete all as specified
M&L in servicing of alternator capacity 200/250 / 320 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insulation tapes, heating and improving the insulation of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alternator, fixing back into the engine and coupling and carrying out alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load allas specified and directed by Engineer-in-Charge.
M&L in servicing of alternator capacity 62.5/82.5/125 /160 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insulation tapes, heating and improving the insulation of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alternator, fixing back into the engine and coupling and carrying out alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load allas specified and directed by Engineer-in-Charge.
M&L for cleaning of fuel tank made of MS sheet up to 20 to 160 KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed
M&L for cleaning of fuel tank made of MS sheet up to 200 KVA to 500 KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed
S&F in replacement of 3 pole ML- 4 Contactor, heavy duty with aux contacts 415 Volt all as per existing make and model complete all as specified and directed.
S&F in replacement 4 pole MNX 45 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode conforming to IEC-60947 all as specified as directed by Engineer-in-charge
S&F in replacement of 220/415 Volt spare coil suitable for MCX-41 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt spare coil suitable for MCX- 32 / 33 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement of 220/415 Volt spare coil suitable for MNX 45 Contactor as per existing make and model complete all as specified and directed.
S&F in replacement 4 pole MCX 32 / 33 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 62.5 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed
Attending and Repair to Three phase input output true online UPS system ((IGBT based - inverter & converter both) with capcity 15 KVA, soldering and testing complete including interlink cables (to connect batteries) and DC cables up to 5 meter (to connect battery bank with UPS) all as specified and directed by Engineer-in-Charge. Note : All spares which to be replaced with new one shall be measured and paid separately.
Supply only Lead acid Battery 12 V 42 AH EP-42 all as specified and directed by Engr-in-Charge
Supply only of Mother board as per existing make of the UPS all as specified and directed by the Engr-in-Charge
Supply only of Sensing transformer as per existing make of the UPS all as specified and directed by the Engr-in-Charge
Supply only of Control card recifier and sensor as per existing make of the UPS all as specified and directed by the Engr-in-Charge
A. R. ELECTRICALS (BID ID -3259658)
M/s Pooja Enterprises (BID ID -3261236)
Tropical Refrigeration (BID ID -3263568)
ANITA VARMA ENTERPRISES (BID ID -3260077)
M/s K Moorthi (BID ID -3260057)
SKY GROUP (BID ID -3263810)
M/S AMBER PAVER PRODUCTS (BID ID -3263875)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .