Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.1 L+₹3.1 L (9.45%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹37.4 L+₹4.4 L (13.4%)Rejected-Finance SHYAM BHAWAN OPP BANK OF INDIA CHOPASNI ROAD JODHPUR 342003 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹42.3 L+₹9.3 L (28.2%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | - | Rejected-Technical Rejected due to over load |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Nov 2022, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION WORKS AT ZONE-II UNDER JURISDICTION OF GE (A) JAISALMER
2022_MES_559051_1
8241/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹90,000
Yes
27 Feb 2023
20 Oct 2022
28 Nov 2022
20 Oct 2022
26 Nov 2022
7 Nov 2022
Amount
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as Main DB's, switches, sockets, fan regulator, replacement of MCB (light/power), lamp holders (bracket/ batten), bell/buzzer, push button, ceiling rose, capacitors, tube light fitting any type, ceiling lights, Flame Proof MCB DB, rotary type switch single pole/double pole, switch socket and plug combined, tube light fitting, flood light fitting and other similar electrical items/fittings etc. including providing of small pieces of electrical wire of size 1 sqmm to 10 sqmm single core and length not exceeding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge.
ITEM NO. 1.00 CONTD... Note :- (i) Any accessories found unserviceable that shall be replaced under respective items of this Sch and shall be measured & paid seperately under Srl item No. 6.00 to 19.00 (ii) Other items like stationery, rent of T&P, misc items like insulation tape, screws, nuts & bolts are deemed to be included in the rates quoted by the contractor. Note for item No. 01 :- (i) Contractor will arrange minimum 2 well experienced electrician and 2 experienced helper to attend repair of internal electrical system at site as required by Engr-in-Charge .Complain should complete the assigned job within 48 Hrs after receipt of the assignment. If the contractor fail to completed the assigned job in the given time recovery will be made Rs. 50.00 @ Per Job.Non reporting of trademen : 300/- per elect /Helper 200/- per helper per day .Providing of safty equipments to the electrician/labour will be responsibility of the contractor.
ITEM NO. 1.00 CONTD... (ii) Details of repair to be collected throughout the contract period from JE E/M at 0900 Hrs from office located at Mil stataion Area. Register of repair should be prepared by the contractor and details of repair to be updated in the register after completion of every repair work. (ii) Contractor will arrange vehicle, electrical tools, folding ladder, misc item like insulation tape, screws, nuts and bolts for repair work.
Taking down of old unsv armoured cable of anytype any size from surface/ casing capping / surface conduit etc as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Taking down the existing unserviceable sheet metal neutral enclosre as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Taking down of old unsv tubelight fitting /bulkhead/ garden light/ gate light of any descriptionlight fitting any type any watt complete all as specified and directed by Engineer-in-Charge.
S&F of Switch modular 6 Amps single pole, one way complete all as specified and directed by Engineer-in-Charge.
S&F of modular Socket outlet, multi purpose, 6 Amps 3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
S&F of modular Bell push 6 Amps 1 module complete all as specified and directed by Engineer-in-Charge.
S&F of modular Socket 16 Amps, 5 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
S&F of modular Switch 16 Amps one way 1 module complete all as specified and directed by Engineer-in-Charge.
S&F of Switch modular 6 Amps two way, 1 module complete all as specified and directed by Engineer-in-Charge.
S&F of switch piano flush type single pole, one way 5 amps, 230 Volts complete all as specified and directed by Engineer-in-Charge.
S&F of switch piano flush type single pole, 2 way, 5 Amps, 230 Volts complete all as specified and directed by Engineer-in-Charge.
S&F of socket outlet flush type 5 Amps, 3 pin, 230 Volts as per IS complete all as specified and directed by Engineer-in-Charge.
S&F of switch socket combination flush type 2 in 1, 5 Amps, 230 Volts complete all as specified and directed by Engineer-in-Charge.
S&F of switch piano flush single pole one way 15 Amp 230 volt complete all as specified and directed by Engineer-in-Charge.
S&F of socket outlet flush type multipurpose 2 in 1, 5 pin 5 and 15 Amp, 230 volts complete all as specified and directed by Engineer-in-Charge.
S&F of switch socket combination flush type multipurpose 2 in 1, 3 pin, 5 and 15 Amp, 230 volts complete all as specified and directed by Engineer-in-Charge.
S&F of bell push single pole, 5 amps, 230 Volts, flush type complete all as specified and directed by Engineer-in-Charge.
S&F in repair of white colour finished mounting modular surface box of suitable size for following sizes:-
(a) One module
(b) Two module
(c) 3 modules
(d) 4 modules
(e) 6 modules
(f) 8 modules
(g) 12 modules
S&F in repair of modular white cover plate with frame inner and outer plates for following sizes:-
(a) 1 module
(b) 2 modules
(c) 3 modules
(d) 4 modules
(e) 6 modules
(f) 8 modules
(g) 12 modules
S&F in repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Fan regulator, step type, flush type, 230 volts 50Hz single phase, piano type, complete all as specified and directed by Engineer-in-Charge.
S&F in repair of modular fan regulator 5 step type, 2 module complete all as specified and directed by Engineer-in-Charge.
S&F PVC insulation Tape roll 20mm width and 8 metre in length for electrical wire colour code red, yellow, blue & black joints complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Bell, AC, 230 Volts, single pole complete all as specified and directed by Engineer-in-Charge.
S&F in repair of buzzer, Ding Dong, AC, 230 Volts,single pole complete all as specified and directed by Engineer-in-Charge.
S&F in repair of ceiling rose, 3 terminal, AC, 230 Volts PVC/polycarbonate, isolated body, single pole complete all as specified and directed by Engineer-in-Charge.
S&F of in repair plastic laminated bakelite sheet cover of hylem 2.8 mm thick including cutting holes for switches, sockets etc as pre requirement including fixing with brass machine screws and washer complete of following sizes:-
(a) 10" x 12" size
(b) 8" x 10" size
(c) 8" x 6" size
(d) 7" x 4" size
(e) 4" x 4" size
S&F in repair of PVC rectangular block gang box for mounting switches, sockets, fan regulator etc including cutting holes for switches, sockets etc as pre requirement including fixing with brass machine screws complete of following sizes:-
(a) 10" x 8" size
(b) 8" x 6" size
(c) 7" x 4" size
(d) 4" x 4" size
S & F in reapir of MCCB DB VTPN 4 way 415 V double door IP 43 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-Charge.
S & F in reapir of sheet metal enclosure double door MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-Charge.
S & F in reapir of sheet metal enclosure double dooor MCB SPN DB 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-Charge.
S & F in reapir of sheet metal enclosure double door MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-Charge.
S & F in reapir of sheet metal enclosure double dooor MCB SPN DB 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-Charge.
S & F in reapir of sheet metal enclosure MCB SPN DB 2 way 240 volts sngle door with magnitic locking system complete all as specified and directed by Engineer-in-Charge.
S & F MCCB 415 V, 16 KA, 4 pole suitable for fixing on DB of capacity 63 Amps with extended terminals complete all as specified and directed by Engineer-in-Charge. Note : MCCB rating ICS =100% ICU
S & F MCCB 415 V, 16 KA, 4 pole suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified and directed by Engineer-in-Charge. Note : MCCB rating ICS =100% ICU
S & F MCCB 415 V, 16 KA, 4 pole suitable for fixing on DB of capacity 125 Amps with extended terminals complete all as specified and directed by Engineer-in-Charge. Note : MCCB rating ICS =100% ICU
S&F MCB's TPN 63-100 Amps, 415 Volts,10 kA 'C' curve complete all as specified and directed by Engineer-in-Charge. Note : MCB TPN rating ICS =100% ICU
S&F in repair of twisted twin core flexible copper cable of size 24/0.20 complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Three core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Three core cable PVC insulated and unsheathed multistranded copper conductor of size 4.0 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Three core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95, Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10%, Necessary mounting arrangements. The fixture shall be suitable for wall mounting /suspension mounting as per site requirement. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per Crompton CAT PART NO Shelter . CIS -305-40-57-SL-DP-NWH or equivalent in Appx 'B' list of makes.
S & F for LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V, 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-Charge.
S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-Charge.
S & F for LED down light recess mounted/Surface mounted/POP mounted or as per site requirement, square/Round type worm white / Neutral white or 3000 K to 6500 K as per user requirement 15 watts with efficiency of 100 lumens per watt, in worm white/ neutral white as per site requirement sleek design aluminium housing polycarbonate diffuser white finish operating voltage from ceiling rose to fitting complete all as specified and directed by Engineer-in-Charge.
S & F recess mounted/Surface mounted/POP mounted or as per site requirement LED down light 5 Watt round/Square in shape worm white / Neutral white or 3000 K to 6500 K as per user requirement Ideal for wardobes, furniture lighting, display & interior decoration complete all as specified and directed by Engineer-in-Charge.
S&F bldg security light fittings Wall mounted LED light 35 Watt including bracket made out of GI pipe (medium grade) 40mm, 1.20 metre long made to shape and fixed outside of the building by means of 2 No FI 40x6 mm clamps with suitable size of nuts, bolts, washers and connecting with three core copper flexible cable of size 1.50 Sq mm complete all as specified and directed by Engineer-in-Charge.
S&F Track light with the high power LED 15 watt cylindro various luminous intensity level from 1500 to 3500 lumen ,which is perfect alternate to conventional HID lamps. Size of Track light Dia 70 mm, length 180 mm, Height 212 mm complete all as specified and directed by Engineer-in-Charge. Make : Havells cat pot No : CYLINDROTS15WLED830S3WIRE38WHT or in Appx 'B' list of Makes.
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable in flexible metalic conduit with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply, laying, fixing 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 Core nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge.
S & F Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 15 watts complete all as specified and directed by Engineer-in-Charge.
M/L for repair/refixing of loosely hanged PV/steel conduit, PVC casing & caping of any type, size by means of shadles, clamps screwes to existing wall/ceiling and making good in all respect incl wiring inside all as shown specified and directed by Engineer-in-Charge.
S&F in repair of PVC conduit pipe of 20mm dia including tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
S & F in repair of LED Bulb warm white 9 Watt of Base E27 complete all as specified and directed by Engineer-in-Charge.
S & F for recess mounted/Surface mounted/POP mounted 2' x 2' square LED panel 36 watts, worm white / Neutral white or 3000 K to 6500 K of size 596 x 596 x 9 mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and directed by Engineer-in-Charge.
S&F in repair, PVC casing, capping of 25mm width ISI marked with all accessories complete all as specified and directed by Engineer-in-charge.
Fixing only MCB Single pole capacity of (6A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB SP (6 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing only MCB Single pole and Neutral capacity of (6A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB SPN (6 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing only MCB Three pole (TP) capacity (25 A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB TP (25 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing only MCB Three pole & Neutral (TPN/FP ) capacity of (25 A to 63 A) and any make complete all as specified and directed by Engineer-in-charge. NOTE :- MCB TPN (25 A to 63 A) shall be issued under Sch 'B' free for fixing only.
Fixing of LED tube light / LED Light fitting /Surface mounted /ceiling mounted/Bulk headlight / building security light fitting of any size or any type complete all as specified and directed by Engineer-in-charge. NOTE :- LED tube light /LED Light fitting of any description shall be issued under Sch 'B' free for fixing only.
S&F fan Capacitor 2.5 MFD, 240 V from Ceiling/Exhaust fan including taking down fan Capacitor complete all as specified and directed by Engineer-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .