Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹9.2 L+₹1.5 L (19.3%)Rejected-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-AOC Not being the lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
19 May 2022, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
REPAIR MAINTENANCE OF COOLING APPLIANCES INTERNAL WIRING ETC AT ZONE A AND ZONE B AREA AT SONEGAON NAGPUR
2022_MES_519470_1
8418/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sonegaon
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) AF Sonegaon
₹20,000
Yes
18 Jul 2022
22 Apr 2022
24 May 2022
22 Apr 2022
19 May 2022
6 May 2022
22 Apr 2022 - 3 May 2022
Amount
S&F in repairs starting capacitor of cap 80/100 MFD 440 Volts Air Conditioner & fixing in position testing etc complete all as specified and directed.
S & F in repairs running capacitor of cap 36 MFD 440 V AC & fixing in position testing etc complete all as specified and directed.
S& F in repairs over load relay suitable for AC split 1.5 ton & fixing in position & testing etc complete all as specified and directed.
S & F in repairs thermostat suitable for AC split type 1.5 ton fixing in position etc complete all as specified and directed.
S & F in repairs thermostat suitable for AC split type 2 ton fixing in position etc complete all as specified and directed.
M & L for refrigerant gas charging with R-22 suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
S & F in repairs sealed/unit compressor with full charging of gas F-12/ R-22 factory winded ( Make : Kirloskar/Shriram or equivalent) suitable for AC 1.5 /2 Ton split type or equivalent including transporting to civil work shop & bring back at site & fixed in position & testing etc all as specified and directed.
S & F fan motor 230 V suitable for AC 1.5 ton split type complete all as specified and directed. (any capacity)
S & F fan motor 230 V suitable for AC 2 ton split type complete all as specified and directed. ( any capacity )
S & F in repairs filter element suitable for AC 1.5 ton Split type of any make complete all as specified and directed.
S & F in repairs filter element suitable for AC 2 ton Split type of any make complete all as specified and directed.
S & F in repairs blower unit for A/C 1.5 ton,/2 Ton of split type complete all as specified and directed.
S& F in repairs remote control suitable for AC split type cap 1.5 ton, 2ton & 3 ton of split type complete all as specified and directed.
M & L for disconnecting unserviceable and corroded top cover of AC split type outer unit of any capacity including replacement with new top cover made out of 02 mm thick MS CRC sheet with necessary bolt, nuts & washers duly painted as per existing complete all as specified and directed.
S&F in repair PCB circuits for ACs 1.5, 2 TR complete all as specified and directed.
S&F in repair PCB circuits(outer unit PCB) for inverter base AC cap1.5/2 TR outer unit complete all as specified and directed.
M & L for disconnecting outer & inner unit of Air-conditioning unit of any capacity including cutting of copper tubes including shifting of outer unit from roof of the building with provision of angle iron anchor pockets made out of 25mmX25mmX5mm angle iron with suitable size of MS plate with installation of outer & inner unit of AC with the suitable space for further maintenance including necessary gas charging / topping up R-22 with soldering of copper tubes complete all as specified and directed.
S & F in repairs sealed unit compressor with full charging of gas F-12/R134 factory winded suitable for refrigerator 185 ltrs capacity of any make carrying out in civil work shop and bringing it back to site, fixing & testing complete all as specified and directed.
M & L for gas charging with F-12/F-22 or equivalent suitable for refrigerator capacity 165/250/310 Ltrs including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
M & L for gas charging with F-12/F-22 or equivalent suitable for deep freezer of various capacity including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
S & F in repairs sealed unit compressor with full charging of gas F-12/ R134 factory winded of capacity 40/60/80 ( Make Kirloskar / Shriram or equivalent) Model 444, 512, 2612 or equivalent carrying out in civil work shop & bringing back to site & testing for water cooler complete all as specified and directed.
S & F in repairs fan motor 230V single phase 1440 RPM suitable for water cooler 40/60/80 Ltrs and fixing in position etc complete all as specified and directed.
S&F in repairs starting capacitor 80/100 MFD 440- V suitable for water cooler any capacity and fixing in position testing etc complete all as specified and directed.
S & F in repairs capacitor 36 MFD 440 V suitable for water cooler any capacity fixing in position testing etc complete all as specified and directed.
S&F in repairs over load relay suitable for water cooler fixing in position testing etc complete all as specified and directed.
M & L for repairs to water cooler body of any capacity including cutting of corroded portion of MS sheet and making new with MS CRC sheet 22SWG for bottom portion and 24 SWG for upper/body portion,repairing of stand including painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F in repairs 15mm ball valves high pressure with polythene float valve and fly nuts complete screwed for iron pipe & fixed for water cooler any capacity complete all as specified and directed.
S & F in repairs stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes for union & fixed of size 15 mm bore complete all as specified and directed.
M & L for refrigerant gas charging with R-12, R-22 or equivalent for water cooler capacity of 40/60/80 Ltrs cap including cutting of copper tubing & soldering etc complete all as specified and directed.
M & L for taking out old unserviceable thermostat from water cooler, supply and fix thermostat complete all as specified and directed.
M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 5 KVA capacity complete all as specified and directed.
M & L for opening of voltage stabilizer, repairing/ rewinding of transformer including heating varnishing and replacing of relay of the 2 KVA capacity complete all as specified and directed.
M & L for taking out old unserviceable volt meter/ amp meter and Supply & fix volt meter/ amp meter for single phase voltage stabilizer complete all as specified and directed.
M &L for rewinding of fan motor any make any size of desert cooler with super enameled copper wire using with suitable gauge including materials such as insulating paper, varnishing, heating/baking and reassembling testing complete all as specified and directed.
S & F in repair of fan motor including cutting dismantling from desert cooler any size as per site complete all as specified and directed.
S & F in repairs vertical pump for desert cooler with GI clamps suitable Upto 5 feet height discharge coolers etc complete all as specified and directed.
S & F in repairs capacitor 4 MFD suitable for desert cooler of any capacity & testing etc complete all as specified and directed.
S & F suitable pad / grass ribs including packing complete set of three for each cooler complete all as specified and directed.
S & F PVC flexible pipe 15 mm bore suitable to desert cooler any capacity for circulation of water etc complete all as specified and directed.
S & F plug top 5 Amp for electric connection of desert cooler etc complete all as specified and directed.
S & F plug top 15 Amp for electric connection for water coolers, deep freezers etc. complete all as specified and directed.
S & F for ply wood 6 mm thick including painting with two coats of synthetic enamel paint over one coat of primer on one side fixing to window face complete wherever required for desert cooler etc complete all as specified and directed.
M & L for preparation of old surface of desert cooler any make any size internally & externally complete body both internal & external surface with two coats of synthetic enamel paint gray shade over one coat of red oxide primer complete all as specified and directed.
S & F in repair including cutting dismantling desert cooler bottom water storage tank with primer & painting of tank cap upto 80 litre complete all as specified and directed.
S & F in repairs PVC copper cable 1.5 sqmm three core for connection of desert cooler complete all as specified and directed.
S & F single pole with a two pin & earth plug & socket complete with one single pole MCB of capacity 20 Amp complete all as specified and directed.
M&L for split AC's checking /rectification of minor problem including washing,cleaning of outer/inner unit with filter by brushes & servicing of inner & outer unit etc complete all as specified and directed.
M & L for refrigerant gas charging with 410-C( gas green) suitable for 1.5/2TR Ton AC including cutting of copper tubes soldering & fixing in position complete all as specified and directed.
M& L for capillary tube 0.060 inch,0.064 inch & 0.072inch suitable for 1.5 TR & 2TR AC as directed by Engineer -in charge complete all as specified and directed.
M & L for taking down carefully copper/aluminium point wiring any type ,surface/concealed/ PVC capping or tubing ( including light,fan,switch socket, or power)complete fittings such as switches, ceiling rose,pendents,regulators,sockets etc complete all as specified and directed.
M & L for taking down old unserviceable main switch board, DB of any type and capacity from its location with accessories MCCB's/ MCB SP/SPN/TPN complete all as specified and directed.
M & L for taking down old unserviceable tube light/cfl light/recessed mounted light or any type of light fittings complete all as specified and directed.
M & L for taking down old unserviceable Sub Main wiring any type any capacity including conduits from its location & making good of distrubed surfaces complete all as specified and directed.
M & L for taking down old unserviceable surface mounting fixed cable 3.5 core16/35/50/70 sq mm or any capacity including LT cable complete all as specified and directed.
M & L for taking down and refixing ceiling fan/cabin fan/ air circulating fan with cleaning & painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler complete all as directed by E- in- charge after minor repairs complete all as specified and directed.
M & L for taking down and refixing exhaust fan with cleaning & painting of exhaust fan complete with synthetic enamel paint by spraying including filling cavities with filler complete all as directed by E- in- charge after minor repairs complete all as specified and directed.
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed in wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
(a) One light point controlled by one switch
(b) One Fan point controlled by one switch
(c) One Exhaust Fan point controlled by one switch
(d) One three pin 5 Amps switch socket outlet on independent board
(e) One three pin 5 Amps switch socket outlet on same board
M&L for point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two runs for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new PVC casing and capping of size 25 x 16mm with accessories fixed on surfaces of wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified and directed for:-
(a) One light point controlled by one switch
(b) One Fan point controlled by one switch
(c) One Exhaust Fan point controlled by one switch
(d) One three pin 5 Amps switch socket outlet on independent board
(e) One three pin 5 Amps switch socket outlet on same board
M & L for all as per item No.58 here in before but point wiring with 2.5 sqmm multistrandard copper cable for 5 Pin 15 Amp switch socket combination on Independent board with one run of 1.5 sq mm multistranded copper cable green colour for earth continuity conductor complete all as specified and directed.
M & L for all as per item No.59 here in before but point wiring with 2.5 sqmm multistrandard copper cable for 5 Pin 15 Amp switch socket combination on Independent board with one run of 1.5 sq mm multistranded copper cable green colour for earth continuity conductor complete all as specified and directed.
Refixing of switch piano, flush type single pole,5 Amps, 240 Volts Ac retreived from Srl Item No 51 complete all as specified and directed.
S&F switch piano, flush type single pole,5 Amps, 240 Volts Ac complete all as specified and directed.
Refixing of ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC retrieved from item no 51 complete all as specified and directed.
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC complete all as specified and directed.
Refixing of switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete retrieved from item no 51 complete all as specified and directed.
S&F switch socket combination 5 Pin,5 Amps,240 Volts, flush type complete all as specified and directed.
Refixing of switch socket combination 2 IN 1, 3 PIN,5 and 15 Amps flush type universal ,240 Volts, complete retreived from item no 51 complete all as specified and directed.
S&F switch socket combination 2 IN 1, 3 PIN, 5 and 15 Amps flush type universal ,240 Volts complete all as specified and directed.
Refixing of Tube light fitting /cfl/LED light fitting wall mounted or recessed mounted any type any make any capacity retrieved from item no 53 complete all as specified and directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector completere wired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable complete all as specified and directed. Make CGCta No-CCS-100-20-65-HL2-DP-NWH/Havells/philips/Bajaj.
S & F 36Watt Recessed LED perforated Single Window modern Designed enabled by advanced LFD light.it blandes into ceiling plane &maintain Uniform luminance across aperature to enhance visual comfort ceiling tile provided with a drop down acrylic diffuser suitable for 600X600 MM ceiling including extra frame for fixing at POP/ Gypsum Ceiling mounted version including LED light complete. The 36W system shall be operating at 220-240v AC supply having internal driver. IP20, surge protection 2KV, ambient temperature (-) 20 to 45 degree C, frequency 50 to 60 Hz. . PF should be greater than 0.95, THD < 10%. Individual LED's should not be visible for glare free output, and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum 1.5 Sqmm size and testing complete, all as specified and as directed Make : CG LCTLRP-36-FO-CDL equivalent in Havells , Wipro.
S&F Mini mirror LINNET LED light 7W lamp 230 volt wall mounting type white reflector suitable for mirror fittings ,connector block etc complete with all connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed..Make-CG Cat No-LCL-07-CDL equivalent in Philips, Bajaj, Havells, Wipro
S& F Recess mounting 18 Watt LED Luminaries Aesthetically designed 1 x 18 Watt LED fitting with Size 300X300MM ceiling including extra frame for fixing at POP/ Gypsum Ceiling mounted version including LED light complete. The 18W system shall be operating at 220-240v AC supply having internal driver. IP20, surge protection 2KV, ambient temperature (-) 20 to 45 degree C, frequency 50 to 60 Hz.complete including connection up to LED fitting with connecting up with copper 3 core flexible cord of minimum sisze 1.5 Sqmm size and testing complete, all as specified and as directed. Make: CG LCTLRNE-18-WW(1x1) equivalent in Havells , Wipro.
Refixing of cable any size any capacity upto 70sqmm fixed on wall with clamps & saddle properly as directed by E-in-charge retrieved from item no 55 complete all as specified and directed.
Refixing of fan step regulator,120 W,220/230 V AC. retrieved from item no 51 complete all as specified and directed.
S & F Fan regulator stepped type electronic fan regulator flush type on the phenolic laminated sheet complete all as specified and directed.
Supply , Laying , connecting,charging, testing and ccommissioning LT cable electric , XLPE insulated, armoured , heavy duty, electric cable 1100 volt grade with stranded aluminum conductor fixed to wall /roofs/ poles all as specified of size as under complete all as specified and directed.
(a) 50sq mm 3.5 core
(b) 35sq mm 3.5 core
Material and labour for submain wiring complete with four runs of 10.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing conduit fixed on walls/ floors/ ceilings etc. alongwith one run of 10.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note : four runs of 10.0sqmm multistranded cable and one run of 10.0sqmm cable as earth continuity conductor shall be considered as one unit length.
Material and labour for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through existing conduit fixed on walls/ floors/ ceilings etc. alongwith one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note : Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor shall be considered as one unit length.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, TPN, 12 way, 415 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 2 way, 240 Volts, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 4 way, 415 Volts, double door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 8 way, 415 Volts, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
S&F MCCBs four pole 415 volts. 16 KA ,100 Amp AC in existing panel board with modification /fabrication of existing panel board as directed by E-in-Charge complete all as specified and directed.
Supply and fix MCCB 200 A, 4 pole, 415 Volts 36 KA breaking Capacity ,AAN frame fixed on Existing panel in power house/feeder panel and connecting up all complete all as specified and as directed & in the process of fixing of MCCB minor drilling, clamping ,screw ,nut bolt included in quoted rate. Make-: L&T/Havells / Hager/Legrand
Refixing of DB's including all existing isolator/ MCCB's/MCB's safely retrieved from Item No 52 complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6-32Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
S&F MCBs 20 Amp DP with necessary connection in DB box complete all as specified and directed.
S&F Isolator TPN 415 volts 63 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F Isolator DP 240 volts 40 Amp AC with necessary connection in existing panel/DB BOX complete all as specified and directed.
S&F Isolator DP 240 volts 63 Amp AC with necessary connection in existing pannel/DB BOX complete all as specified and directed.
Paragon Electrotechnics
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .