Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.9 L+₹98,402 (6.60%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹16.0 L+₹1.1 L (7.26%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | Rejected-Technical No remarks in WLR |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
29 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Jiagar Trivedi, SM
HQ CWE (AF) Gurgaon Old Palam Road Delhi Cantt - 10
REPAIR/MAINT OF HT CABLES, ELECTRIC EQUIPMENTS, HT POLES WITH ALLIED WORK SERVICES OF ELECTRIC SUPPLY AT AF STN DADRI UNDER GE (AF) FARIDABAD
2022_MES_535120_1
CA NO CWE/GGN/FT-06/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AF Stn Dadri
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Faridabad
₹34,000
Yes
13 Sept 2022
1 Jul 2022
6 Aug 2022
1 Jul 2022
29 Jul 2022
16 Jul 2022
1 Jul 2022 - 15 Jul 2022
Amount
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 95 sqmm 3 core XLPE armoured aluminium conductor all as specified and testing after jointing complete .
Supply & fix in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 95 sqmm 3 core XLPE armoured aluminium conductor cable ofcomplete with jointing material and accessoies complete all as specified and testing after jointing complete .
S&F in repair out door type cable straight through joint heat shrinkble type suitable for HT UG cable of size 95 sqmm 3core 11KV of aluminium conductor all as specified and testing after jointing complete all as specified.
Supplying installing,in repair testing and commissioning of air break, gang operated, triple pole switch, outdoor, vertical mounting type of capacity 200 amps, ISI marked, mechanically operated on insulators and frame work with operating mechanism worked from ground level, with locking arrangements including 65 mm pad lockes with two keys, complte with fuse mounts, fuse carriers and HT fuse elements having suitable rating rating suitable for HT 11 KV, 50 Hz Ac Supply incl necessary electric connections complete all as specified.
Dismantling & taking down old, deteriorated, lightening, arrestor and supply and fixing litghtening arrestor expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 Volts complete all as specified.
M & L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out all as specified.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart all as specified.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified.
M&L for sub class `B` bricks for cable protection all as specified.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core incl thimbles as required with suitable size of calmps on wall/under trenches incl taking out/down old u/s cables etc all as specified.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core incl thimbles as required with suitable size of calmps on wall/under trenches incl taking out/down old u/s cablesetc all as specified.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core incl thimbles as required with suitable size of calmps on wall/under trenches incl taking out/down old u/s cables etc all as specified.
M&L for earthing in repair complete with galvanized mild steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip of size 25mm x 4 mm as earthing lead by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber) shall be of size 300mm x 300mmx 300mm (internal dimensions) using PCC 1:2:4, type B-1, using 20mm graded stone aggregate coping shall be of PCC 1:3:6, type C-1, using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge (0.68mm) 8 mesh per linear inch, 80mm thick RCC cover of size 320mm x 320mm, made out with RCC 1:2:4, type B-1, using 20mm graded stone aggregate, reinforced with four Nos 8 mm dia TMT bars @80mm centre to centre, both ways and charcoal dust and common salt all as shown in Electrical plate No 3 of SSR Part-I (2009) and specified including 40mm dia GI medium grade pipe as protection pipe and watering pipe shall be 20mm bore GI medium grade including necessary excavation and earth work & connecting the earthing to an earthing test point as specified and testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L and testing for Advance Maintenance Free environment friendly chemical earthing as per IS 3043 with copper strip of size 40 x 6 mm, 3 mtr long, 50mm dia outer pipe of thickness 2mm filled with highly conducting metellic compound in gel foam and boath end sealed, electrolytic copper eathing electrodes. The earth pits shall be filled with sufficent quality ultra high conductive black fill compound with neccessary accessories like lockable pit cover and PVC 16 sqmm single core multistrand PVC insulated copper conductor drawn in HDPE pipe bore 25mm Including test point terminal block made of gun metal phosphorus bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws and Hot dip galvanised sheet 2 mm thick box of size 200 x 100 x 100 mm with Hexagonal head screws 125 mm complete as required all as per standard practices and specifications. Note: The concrete pit shall be PCC 1:3:6 type c-140 mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm aggregate reinforced with 8mm TMT bars @ 10 cmm c/c on both sides with suitable cast iron handle shall be provided in liew of cost iron cover
M&L for MS Duct covers of Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as directed .
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed .
Complete all as per Srl Item No 18 but for HT, 25x20cm size complete all as directed .
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms two pole/ foure structure surroundings to make a over all presentable condition all as directed by Eng In charge.
Supply and loose filling stone Aggregate of gauge 40 to 80 mm grade in Two pole/4 pole electrical sub stn area complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety Supply incl all fixing adhesives etc complete all as specified.
S&F XLPE insulated aluminium conductor single core cable inulated for jumper suitable for HT 11000 volts overhead lines of size 95 Sqmm including making binding with GOD switches/insulators/ conductors and connection with GOD switches (length of jumper shall be 4 mtr but not more than 5 mtr long) complete all as specified.
Complete all as per Srl item No 23 above but of size 95 Sqmm (length of jumper shall be 1.5 mtr but not more than 2 mtr long) complete all as specified.
M&L for Painting of steel surface of HT/LT Steel tubular pole existing colour over 10cm width or girth or less in girth or in small article such as brackets 'D' clamps etc with one coat of aluminium paint after prepration of surfaces all as specified.
M & L for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer ,Voltage stabilizer, HT OCB, ,HT VL switches with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV complete. Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive at above. (ii) Filtered oil should be with stand for one minute on voltage applied 50 KV at 4mm gap (iii) Test result will be recorded before and after filtration of oil.
M& L for topping up new transformer oil having dielectric strength not less than 55 KV, to transformers at various sub stations as directed. Note :- (i) New insulating oil shall be obtained in sealed steel container 200 Ltr cap duly ISI marked on drum and produced for approval before use. (ii) Transformer oil shall be obtained from reputed manufacturer.
M&L for Taking down carefully transformer upto capacity 500 KVA, any make, any type from plinth / substation by dismantaling, dis-connecting HT & LT sides, earthings of transformer, supporting angles/crossarms, Shifting / transporting transformer carefully from the site to the workshop and refixing at site after carryout and connecting with following works repair with all electrical connections incl testing.
M&L for Opening of top cover by unscrewing nut, bolts & washersetc and taking out core assy from tank by disconnecting from tap changer HT & LT side bushing studs to outside by dismantling the channel and disconnecting star delta connection including testing -
M&L for Removing the lamination in proper manner carefully for taking out serviceable / un serviceable HT/LT coils from the limbs including testing complete etc all as specified and directed.
M&L for Rewinding of HT coils with copper wire DPC/ super enameled high quality matching with existing gauge and impedance including requisite paper/material in each layer or winding including testing complete etc all as specified and directed.
M&L for Rewinding of LT coils with copper strips including testing complete etc (NOTE :- The rate quoted against the item is inclusive of cost of all types of insulating materials and heating/ varnishing etc.,)
M&L for Inserting of HT/LT coils on limbs rewinded here in before / old after cleaning of lamination in proper way after insulating the limbs with requisite insulating materials on limbs in between limbs/coils including testing complete etc all as specified.
M&L for Rearrange the top lamination over coils in proper manner including fixing of top channel soldering in between coils as necessary and brazing of star delta connection with tap changer including testing complete etc
M&L for Baking the core assy in the oven duly varnishing the coil to improve IR value and to eliminate moisture including testing complete etc
M&L for Inserting core assy after baking in the tank (before inserting tank to be cleared by removing all deposit sludge etc including drying) and making connecction with HT/LT bushing studs and closing the tank top cover by fixing nut, bolts and washers ( Top cover gasket will be measured and paid separetely) including testing
S&F in renewal of transformer bushing LT side upto 500 KVA including brass set stems conical bush/ gasket, tightning by using spring and star washer for indoor/outdoor transformer by for the following capacity including testing complete etc all as specified.:- NOTE:- the rate quoted is deemed to be including the cost of necessary labour charges for draining out transformer oil, opening of top cover by unscrewing nut, bolts washerrs and suitable size pad type busbar aluminium and nutbolt washers etc.,
M&L for service, Repairs to the leaks of transformer from tap switch/ fins/ any pats of body, gauges by replacing gasket / seal , or Repairs to the leaks of transformer body / fins, by welding / brazing etc
M&L for service, Repairs to Servo voltage stabilizer including replacement of parts of body, volt meter, Amp meter, display by replacing gasket / seal , Repairs to the leaks , by welding / brazing etc complete all as specified and directed.
M&L for replacement of drain valve brass of suitable any size 25mm bore ISI marked.
Supply and fill up in replacement of defective silica gel in breather assy
Supply and fixing Breather assembly complete suitable for power distribution transformer of capacity up to 200 KVA including taking out old unserviceable breather
Supply and replacement temperature gauge 0-100 degree Celsius range dia type complete all as spd and directed.
M&L for Servicing, testing, commissioning of VCB including all minor spare parts complete etc all as specified and directed.
M&L for auguring of holes in true horizontal position under road by means of mechanical rig after doing ultrasound to prevent any damage to existing cable/pipe line coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long incl laying HDPE pipe not less than 150mm dia complete all as specified.
M & L for serching fault location of HT/LT UG cable 415 Volt laid in trenches /ducts with the help of eletronic fault locating machine comprising of surge generator pulse ,ECHO fault locator with freqency distance calculator etc incl transportation of machinary from Delhi cantt .Excavation in normal soil starta exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs complete.
Net Contract Sum will be after deducting Sch of Credit of Rs 1,10,828.00
Singh Associates
Akhil Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .