Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L1 | Accepted-AOC aoc | |
| 2 | L2₹18.5 L+₹2.5 L (16.0%)Rejected-Finance 28 AVANTIBAI MARKET MAKRONIA SAUGOR MP 470004 | SAUGOR | SAGAR | MP | 470004 | L2 | Rejected-Finance Second lowest bidder | |
| 3 | L3₹19.6 L+₹3.6 L (22.8%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L3 | Rejected-Finance Third lowest bidder | |
| 4 | L4₹20.2 L+₹4.3 L (27.1%)Rejected-Finance SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | L4 | Rejected-Finance Fourth lowest bidder | |
| 5 | L5₹21.5 L+₹5.5 L (34.8%)Rejected-Finance | L5 | Rejected-Finance Fifth lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Jun 2020, 6:00 pmClosed
GE Saugor
GE Saugor
REPAIR AND REPLACEMENT OF LT CONDUCTORS AND CABLE WITH ALLIED WKS PERTAINING TO PREMONSOON ELECTRICAL WORKS UNDER GE SAUGOR
2020_MES_341157_1
GE/SGR/TOK-08 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Saugor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Saugor
₹40,000
Yes
25 Aug 2020
27 Apr 2020
2 Jul 2020
27 Apr 2020
30 Jun 2020
13 May 2020
Amount
S&F in repairs cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint including existing cross arms, bracing, etc complete all as specified and directed.
S&F in repairs framed work as in doors or gates of angle made out of Fe 410-W Gde E-250 quality -A or other section with gusset plates, rails, fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
M&L for fabrication of existing panel cover with hing, nut, bolt and applying two coats of synthetic enamel paint complete all as specified and directed
S&F stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 16 mm dia including loop insulator suitable for 1.1 KV (size 65x90 mm) with clearance of hole 16 mm and MS stay plate size 230 x 230 x 6mm, stay clamps etc including taking down exisitng stay assembly complete all as specified and directed
S&F in repairs galvanised stay strand 7/3.15 mm or 7/4.00 mm size with minimum tensile strength of 700 N/ Sqmm and conforming to IS : 2141-1979 complete all as specified & directed.
S&F aluminium conductors steel reinforced (ACSR conforming to IS : 398) Part-II)-1976 for HT/LT over head lines on PCC/ steel/rail poles including aluminium binding wire including taking down exisitng aluminium conductors complete all as specified and directed
S&F in repairs GI wire 4mm dia (8 SWG) stretching and fixing on pole for continious earth conductor, Guard wire 3.2 mm (10 SWG) for cradle (Hexagonal/rectangular) including binding wire complete all as specified and directed
S&F in repairs pin type, vitreous, white, brown or green insulator including galvanised mild steel spindle, two Galvanised iron washers and one GI nut 100 mm height , 65 mm dia suitable for 1100 Volt working pressure grade (LT) complete all as specified and directed
S&F in repairs shackle type porcelain, vitreous, white, brown or green insulator including Galvanised Mild Steel straps, washers, suitable bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 volts working pressure grade (LT) complete all as specified and directed
Supply, jointing and testing in repairs outdoor type heat shrinkable End termination cable joint including all material and accessories suitable for 3 core x 50 -95 Sqmm earthed XLPE cable of 11000 Volts grade all as per manufacturer’s recommendations complete all as specified and directed. Make - M Seal/Denson/3M
Supply, jointing and testing in repairs outdoor type heat shrinkable End termination cable joint including all material and accessories suitable for 3 core x 120-185 Sqmm earthed XLPE cable of 11000 Volts grade all as per manufacturer’s recommendations complete all as specified and directed.
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed
S&F in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed
S&F in repairs earth continuity conductor or main earthing strip 32 x 6 mm GI strip laid in pipe/ fixed to poles or any other indicated situation including jointing by using GI nuts, bolts and washer in addition to welding incl GI pipe suitable size complete all as specified and directed
S&F in repairs Air Break switch Gang operated triple pole with DO fuse assembly, mechanically operated on insulator and steel frame with operating mechanism from ground level for current rating of 200 Amps and 11000 Volt pressure complete all as specified and directed
S&F in repairs lightening arrestor expelsion type complete with fittings transmission class discharge capacity 10 KA suitable for 11000 Volt complete all as specified and directed
S&F in repairs pin type porcelain vitreous white or brown or green insulators of size 150 mm height and 150 mm dia for 11 KV grade and on galvanised mild steel spindle, two GI washers and one No GI nut confirming to IS complete all as specified and directed
S&F in repairs disc type insulator porcelain, vitreous white, brown or green of size 145 mm high and 255 mm dia ball and socket type with clamps suitable for single disc assembly for tension with tension clamps for ACSR conductor working pressure of 11000 volts complete all as specified and directed
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregates) in foundation of PCC poles/ struts, etc. including all necessary form work including demolition of cement concrete not exc 15cm thick above or below ground level complete all as specified and directed
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregates) as in foundation of stay assy/ pole etc, including form work complete in all as specified and directed
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate for coping/plinth of poles, including all necessary form work surface finished even & smooth without using extra cement complete all as specified and directed
Supply and erection of pre-stressed concrete pole in vertical position 9 meter long 102mm X 172mm at top and 102mm X 279mm at bottom class-10 confirming to IS-1678 and including marking alternate white and black strips 30cm height with two coats of synthetic enamel paint over a coat of primer including dismantling concrete poles/ struts, any size complete all as specified and directed
M&L for earthling complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25m below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth lead 4.0 mm dia as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 40 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate No 3 of SSR 2009 part I complete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, burried directly in ground,earth pit not less than 2.25m deep below ground level with top edge of earth plate not less than 1.5 meter below ground level, steel earth plate connected with 32 x 6 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 5 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 meter connected to Panel board all as specified Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Excavation in trenches in any type of soil not exceeding 1.5metre wide and not exceeding 1.5metre in depth and getting out complete all as specified and directed .
All as per Srl item No.25 above but exc 1.5m and n exc 3.0 m depth in any type of soil
Taking down and re-Laying LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 16 to 95 Sqmm 3 core/3.5 laid in trenches or fixed on wall/floor/poles including taking out old unserviceable/ serviceable bricks/cable covers/GI pipe of any size from trenches complete all as specified and directed
Taking down and Re-Laying LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 120 to 300 Sqmm 3.5 laid in trenches or fixed on wall/floor/polesincluding taking out old unserviceable/ serviceable bricks/cable covers/GI pipe of any size from trenches complete all as specified and directed
Taking down and Re-Laying HT UG armoured heavy duty electric cables 11000 volts grade with aluminium conductor of size 95 to 185 Sq mm 3 core laid in trenches or fixed on poles including taking out old unserviceable/ serviceable bricks/cable covers/GI pipe of any size from trenches complete all as specified and directed
M&L for laying of bricks ofsub class 'B' (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable omplete all as specified and directed .
Supplying and laying reinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm omplete all as specified and directed .
Removing excavated materials (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point omplete all as specified and directed .
Returning filling in with excavated soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
M&L for sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building omplete all as specified and directed .
S&F in repairs GI pipe iron light grade of 50mm bore ( ISI marked ) with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables omplete all as specified and directed .
All as per Srl item No 35 above but 80 mm dia
M&L for preparation old painted surfaces of PCC pole (Cross arms, clamps etc) and applyingth two coats of aluminium paint upto the height of 1.2 m of 9m pole longand making colour bands with two coats of synthetic enamel paint and rewriting the pole numbers complete all as specified and directed.
M&L for preparation of old painted tubular/ rail pole (cross arms, clamps etc) steel surfaces and applying two coats of aluminium paint upto the pole height of 9m pole w and making colour bands with two coats of synthetic enamel paint and rewriting the pole number complete all as specified and directed.
M&L for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and remove to a distance not exc 50 mtr complete all as specified and directed
M&L for cutting /trimming of tree branches upto 80 mm girth along LT/HT OH electric lines which or growing /touching or falling on ACSR conductor /poles or near by sub stns etc at any height from GL and making sufficient clearance not less than 1.5 mtr from ACSR conductor/ poles/ structure and taking down the same on the ground carefully avoiding the damage of and removing to a distance including stretching of conductor as required where directed by Engr - in -charge. Note :- Tree cutting will be maintain for periodisity for three months depending upon the grougth of three branches.
Re-Streaching of Aluminium reinforced conductor by opening from insulators and refixed with streached complete all as specified and directed
S&F in repairs straight through cable joint suitable for LT armoured cables, PVC insulated, aluminium conductor, 1100 volts grade type for 25 to 35 Sqmm 3 ½ size type SLA – 4 complete all as specified and directed. Make: M- Seal/ Denson
All as per item No 42 but 50 to 95 Sqmm 3 ½ core size type SLA – 5
All as per item No 42 but 120-195 Sqmm 3 ½ core size type SLA – 6
M&L for LT line PVC spacers spiral type for two line (separator) complete all as specified and directed
Supplying, Laying and spreading of 40mm graded crushed stone aggregates complete all as specified and directed.
M&L for checking and finding out pin point location of fault in HT 11 KV underground cable with the help of fault locating mobile machine complete all as specified and directed. (Note : excavation used for fault find out included in the quoted rate.)
S & F in replacement of complete unit of capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V & 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity complete all as specified and as directed . Make - NEPTUNE/ SCHNEIDER// L&T
All as per Srl item No. 48 above but of capacity 10 KVAR complete all as specified and as directed by Engineer-in charge. Make: Legrand /Siemens/L&T
All as per Srl item No. 48 above but of capacity 12.5 KVAR complete all as specified and as directed by Engineer-in charge. Make: Legrand /Siemens/L&T
All as per Srl item No. 48 above but of capacity 25 KVAR complete all as specified and as directed by Engineer-in charge. Make: Legrand /Siemens/L&T
Checking of G8 plus power controller thyristor based APFC panel of any size and any capacity with minimum requirement of material like relay, contactor, modules all as per site requirement complete all as directed. (Note : Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement, entire APFC panel should be capable of capable of improvement of PF upto 0.995 on the average of monthly consumption, at the different loads of Pump set and during the off load entire installation even at No Load.
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 10 sqmm, 2 core stranded conductor in service conections including taking down existing cable complete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 10 sqmm 4 core stranded conductor in service conections complete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying.
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 16 sqmm 4 core stranded conductor in service conections complete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying.
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 25 sqmm 3.5 core stranded conductor in service conections including taking down existing cable complete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 35 sqmm 3.5 core stranded conductor in service conections including taking down existing cable complete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying.
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 70 sqmm 3.5 core stranded conductor in service conections including taking down existing cablecomplete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying.
Laying only or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed cross - sectional area 90 sqmm 3.5 core stranded conductor in service conections including taking down existing cable complete all as specified and directed. Note:- Cable shall be issued under Sch 'B' as free for laying
S&F in repairs MCCB 4 pole 415 volt adjustable type 400 Amps with breaking capacity 36 KA complete all as specified and directed. Make: - Legrand /L&T/ Havells
S&F in repairs MCCB 4 pole 415 volt adjustable type 350 Amps with breaking capacity 25 KA complete all as specified and directed. Make - Legrand /L&T/Havells
S&F in repairs MCCB 4 pole 415 volt adjustable type 250 Amps with breaking capacity 25 KA complete all as specified and directed. Make - Legrand /L&T/Havells
S&F in repairs MCCB 4 pole 415 volt adjustable type 200 Amps with breaking capacity 25 KA complete all as specified and directed. Make - Legrand /L&T/ Havells
S&F in repairs MCCB 4 pole 415 volt adjustable type 160 Amps with breaking capacity 25 KA complete all as specified and directed. Make - Legrand /L&T/ Havells
S&F in repairs MCCB 4 pole 415 volt adjustable type 125 Amps with breaking capacity 16 KA complete all as specified and directed. Make - Legrand /L&T/ Havells
M&L for checking of battery charger of any size and any capacity with minimum requirement of material all as per site requirement complete all as directed. Note : Quoted rates shall be deemed to include opening of bettery charger accessories and taking the defective items to the approved workshop
SHRI RAM ELECTRICALS ENTERPRISES
M/S JAINENDRA KUMAR JAIN
shubhanshu traders
shivansh traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .