Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Deducts after sch of credit | |
| 2 | L2₹7.7 L+₹4,427.60 (0.58%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹8.3 L+₹66,170 (8.66%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹8.5 L+₹86,822 (11.4%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹8.6 L+₹92,899 (12.2%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
29 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 900120 CO 56 APO
Repair Replacement to different type of security lights junction boxes flood lights high bay fittings and connected works at Ralawas under AGE I Nagtalao
2020_MES_377013_1
8316/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I Nagtalao
₹19,000
Yes
15 May 2021
12 Sept 2020
30 Sept 2020
12 Sept 2020
29 Sept 2020
17 Sept 2020
60 days
Amount
Taking out existing LT under ground cable 1100 volts grade PVC insulated armoured aluminium conductor of size 16 sqmm to 50 sqmm from trenches/duct/pipes, on walls, poles of following unserviceable cable from site to store
M& L for laying only cable XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes Note:- LT UG Cable will be issued under Sch B free for laying only (a) 16 Sqmm 4 core
(b) 25 Sqmm 4 core
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtr deep in hard /dense soil for laying underground cables and post holes complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point.
M&L for sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed by EIC. Note :- Punned thickness only shall be measured and paid.
Laying only old retrieved stone putty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified and directed by Engr-in-charge.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified and directed by Engr-in-charge.
Supply and lay light grade GI pipe with all fittings complete laid in trench/ fixed to Wall / Poles etc with suitable clamp for any type of pole, nuts, bolts washers etc required at site for protection of cable of the following sizes:- (a) 25 mm dia
(b) 40 mm dia
Supply and errection of steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with CI base plate complete all as specified and directed by EIC. Note: PCC and earth work will be measured and paid separately.
M&L for PCC (1:3:6) type C-2 with using 40mm grade stone aggregate as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
M&L for coping with 20 mm graded aggregate in the ratio of 1:3:6 Type C-1. complete all as specified and directed by Engr-in-Charge.
Dismantling of old unsv cable junction box of any size and type by unscrewing nut and bolts from the pole complete all as directed by EIC.
Supply and fix thermoplastic cable junction box IP 65 with plain walls of size 210x310x116mm and making suitable size hole for cable entry complete with cable terminals/connectors and other fittings fixed on poles with MS flat iron nut bolts, washers and double compressor metal glands of suitable sizes etc complete all as specified and directed etc all as specified and directed by EIC. ( Note :- MCB will be issued under Sch 'B' free for fixing only (6-32 Amp)
S&F security light bracket in repair made out of 40 mm bore GI tubing light grade 1.50 mtr long bend to required shape as in bracket for street light fittings fixed with two pair of MS flat iron clamp not less than 30 mm width and 4mm thick of appropriate length in required shape suitable to 40 mm GI pipe (as per site requirement) with bolts, nuts, and washers and other petty items required for fixing including painting with two coats of syntheitic enamel paint over a coat of redoxide primer complete all as specified and directed by Engr-in-charge.
S & F in repair PVC insulated unsheathed flexible aluminium conductor cable 2.5 Sqmm three core multi-standard 1100 volt grade drawn through light grade GI pipe with all accessories like suitable size of clamp, nut, bolt, washers etc to fixed on pole, wall or in floor complete all as specified and directed by Engineer-in-Charge. (NOTE : GI pipe will be measured and paid seperately under relevent item of this schedule)
Taking out Old U/s Pipes including junction boxes of any size and type from the existing PCC/LT swaged pole and Supply and fix 40 mm dia GI pipe of light grade (ISI Marked) with suitable size of MS clamp , nut, bolts, washers up to the Junction box of pole (Length of pipe should not be less than 2 runs x 1.0 RM) for protection of cable , refixing the existing junction box including making arrangment for locking of junction boxes where ever required and including necessary excavation/broken to existing surfaces/coping to the pole and providing new coping with type B1 1:2:4 PCC (20 mm graded aggregate ) of size approved by Engineer-in-Charge and making good disturbed surfaces to match with original surfaces complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of petty items like clamps, nuts, bolts etc required for refixing the junction boxes will be deemed to be inclusive of quoted rates. (ii) Excavation & earthwork for taking out loop of cable, relaying including sand cushioning , quarry faced stone returning filling and removal of surplus soil complete will deemed to be inclusive of quoted rates (iii) Cost of making of connection to the cable in junction box including insulation with water proof insulation tape of suitable size will deemed to be inclusive of quoted rates.
Taking down old unserviceable any type and marked wattage of Security light/flood light /post top lantern from the any height of the pole/buiding / gate and making good disturbed surfaces to match with existing complete all as specified and directed by Engineer-in-Charge.
Fixing only, LED street light fitting of any Wattages by means ladder/manupulator, any height of PCC/LT Swaged pole/Wall complete all as specified and directed by Engineer-in-Charge. Note:- LED street light will be issued under sch 'B' free for fixing only (ii) Any petty items required for fixing is deemed to be inclusive of quoted rates.
Fixing only, LED flood light fitting of any Wattages by means ladder/manupulator, any height of PCC/LT Swaged pole/Wall complete all as specified and directed by Engineer-in-Charge. Note:- LED flood light will be issued under sch 'B' free for fixing only (ii) Any petty items required for fixing is deemed to be inclusive of quoted rates.
Supply and fixing smart LED highbay luminaries rectangular type which saves more energy as compared to conventional fixtures having 150 watts as system wattage and lumens efficiency 120 lm/watt or above and total system lumens output is 18000 or above having LED Module fitted in the fixture in well arranged matrix with individual optical lenses for optimum output , the fitting housing should be pressure die cast aluminium housing having degree of protection IP 66, toughned glass as front cover, operating voltage range 140 to 270 volts , the driver of the fixture should be plotted type for maximum performance and it should be RoHS complaint with BIS-R Mark Registered No and the surge protection of the fitting should be 5 kv complete making connection with Copper conductor multristranded single core FRLS wire 3X 1.5 sqmm, smart LED highbay luminaries shall be crompton cat No LHBN-150 - CDL/60 or equivalent in Wipro/Phillipsas approved by AGE (I) Nagtalao. Note:- (i) Cost of the manipulator/ ladder for fixing of light in hangar will deemed to be inclusive in quoted rates. (ii) All highbay fittings is to be tightened with truss/angle by using suitable size of GI wire.
Fixing only, LED garden/ post top light fitting of any Wattages by means ladder, any height of gate /Wall complete all as specified and directed by Engineer-in-Charge. Note:- LED Garden / Post top light will be issued under sch 'B' free for fixing only (ii) Any petty items required for fixing is deemed to be inclusive of quoted rates.
S & F in repairs for submain wiring with two runs of 2.5 Sqmm size main cable and one run of 2.5 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable with multi stranded copper conductors, 1100 V grade, IS- 694 marked all drawn through & including, pvc conduit of suitable size including accessories all fixed to the surface of wall/ceilings complete all as specified. Note:- Two runs of 2.5 Sqmm multi stranded copper (FRLS) cable and one run of 2.5 Sqmm of single core multi stranded copper conductor cable including relevent pvc conduit shall be measured as one unit length.
Dwarka Enterprises
vinayandsons
S R ENTERPRISES
Shri Electrical Enterprises
M/S JAGDAMBA ENTERPRISES
Surendra Singh
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .