Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | ₹12.2 L | L1 | Accepted-AOC Quoted rate found Lowest (L1). |
| 2 | L2₹14.5 LRejected-Finance 24A BARICKPARA ROAD FLAT NO 2A 2ND FLOOR KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | ₹14.5 L | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). |
| 3 | L3₹20.1 LRejected-Finance | ₹20.1 L | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified. |
| 5 | Rejected-Technical FLAT NO 81 BLOCK C INDUSTRIAL HOUSING ESTATE SHYAMNAGAR SHYAMNAGAR SHYAMNAGAR NORTH 24 PARGANAS WEST BENGAL 743127 | 24 PARAGANAS NORTH | WEST BENGAL | 743127 | - | - | Rejected-Technical Technically Disqualified. |
| Sl No | Description | Qty | Unit | GLYPTIC L1 | Romeetech Engineering & Services L2 | DES TECHNICO LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable 4 Loops fire alarm control panel having expandable features ( VDS / UL / FM / ULC approved ) fully networkable with each loop capable of taking minimum 120 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type.The panel shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. | ||||||
| 1.01 | The panel shall have in built rectifier, provision for external & internal printer (if required), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required. The panel shall have extra loop card to serve as stand by in case of burntout or malfunctioning of any operating loop cards. The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS (RS 485). The panel should have modbus output & ready to communicate with remote computer. The system must be preloaded with licenced software. (Make: Esser / Cerberus Pro / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls). | 1 | No | - | - | - |
| 2.00 | SIT & C of Analog Addressable Intelligent multisensor detector (VDS / UL / FM / ULC approved ) with two inbuilt optical smoke sensors with backward & forward scattering light angles as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls). | 140 | Nos | - | - | - |
| 3.00 | SIT & C of Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make: Esser / Cerberus Pro / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Contros). | 10 | Nos | - | - | - |
| 4.00 | SIT & C of conventional addressable Beam detector with mounting base alongwith input module( VDS / UL / FM / ULC approved) (Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo/ Morley / System Sensor / Johnson Controls). | 3 | Nos | - | - | - |
| 5.00 | SIT & C of Addressable Manual Call Point ( VDS / UL / FM / ULC approved )soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Make: Esser / Cerberus Pro / Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls). | 21 | Nos | - | - | - |
| 6.00 | SIT & C of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and (VDS / UL / FM / ULC approved) approved. (Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls). | 14 | Nos | - | - | - |
| 7.00 | SIT & C of Addressable transponder/ Monitor Modules ( VDS / UL / FM / ULC approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. (Make: Esser / Cerberus Pro / Secutron / Notifer / Edward / Bosch / Apollo / Morley / System Sensor / Johnson Controls). | 10 | Nos | - | - | - |
| 8.00 | SIT & C of Addressable Relay Modules (VDS / UL & FM approved) for switching / integration of Lift / AHU etc complete as required. | 10 | Nos | - | - | - |
| 9.00 | SIT & C of LED type Response Indicator ( VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Make: Esser/Cerberus Pro/Secutron/ Notifer / Edward / Bosch / Apollo / Morley / System Sensor /Johnson Controls). | 30 | Nos | - | - | - |
Tender Value
Refer Docs
EMD Value
₹52,500
Closing Date
27 Jun 2019, 1:00 pmClosed
Executive Engineer, PWD, Malda Electrical Division
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Repairing and renovation of Rabindra Bhavan, Malda in the district of Malda-Electrical Installation and allied Works-Supply, Installation, Testing and Commissioning of Fire detection and Alarm system.
2019_WBPWD_227334_1
WBPWD/EE/MED/e-NIQ-08/2018-19 (3rd Call)
Open Tender
Electrical Work/ Equipment
30 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹52,500
14 May 2026
10 Jun 2019
29 Jun 2019
11 Jun 2019
27 Jun 2019
11 Jun 2019
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
Tendernotice_2.pdf
PDF • 0.68 MB
Tendernotice_3.pdf
PDF • 2.92 MB
BOQ_414334.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid