Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹10.5 LQualified Make: NUMERIC
Model: Numeric Keor T AYODHYA BYPASS ROAD BHOPAL MADHYA PRADESH 462041 | BHOPAL | MADHYA PRADESH | 462041 | Make: NUMERIC
Model: Numeric Keor T | L1 | Qualified | |
| 2 | L2₹11.0 L+₹48,000 (4.57%)Qualified Make: NUMERIC
Model: Numeric Keor T 3 JADULAL MULLICK ROAD KOLKATA KOLKATA WEST BENGAL 700006 | KOLKATA | WEST BENGAL | 700006 | Make: NUMERIC
Model: Numeric Keor T | L2 | Qualified | |
| 3 | L3₹11.0 L+₹49,000 (4.67%)Qualified Make: NUMERIC
Model: Numeric Keor T 61 62 6TH FLOOR 61 62 6TH FLOOR KALPATARU SQUARE KONDIVITA ROAD OFF ANDHERI KURLA ROAD ANDHERI EAST MUMBAI MAHARASHTRA 400059 MUMBAI MAHARASHTRA 400059 | MUMBAI SUBURBAN | MAHARASHTRA | 400059 | Make: NUMERIC
Model: Numeric Keor T | L3 | Qualified | |
| 4 | L4₹11.0 L+₹49,600 (4.72%)Qualified Make: NUMERIC
Model: Numeric Keor T 3 ARBUDANAGAR AT AND PO VADGAM VADGAM BANASKANTHA GUJARAT 385410 | BANAS KANTHA | GUJARAT | 385410 | Make: NUMERIC
Model: Numeric Keor T | L4 | Qualified | |
| 5 | L5₹14 L+₹3.5 L (33.3%)Qualified Make: NUMERIC
Model: Numeric Keor T 5 JAMUNA GANGA JAMUNA APARTMENT NR HOTEL NEST OFF C G ROAD NAVRANGPURA AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Make: NUMERIC
Model: Numeric Keor T | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
25 Oct 2018, 12:00 pmClosed
Online UPS ( PAC Only ) Experience with Gov. Required 3 Year (s) Online UPS ( 2 ) ( Under PAC ) Make numeric Model numerickeort Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 30.0 KVA * Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power Three phase 300 V - 450V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user 1/4 setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 15
30
60
90
120
180
240 Minimum VAH (VAH) 48000 400-640000 Warranty for UPS (Years) 3 1
2
3
4
5 Movable trolly for Batteries Without trollery but with rack With
Without
Without trollery but with rack Warranty for battery 2 1
2 Degree of Protection IP20 IP21
IP20 Cabling 5 meters for input and out put Without With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt Yes * 2/4 age
Current
Frequency
Battery Voltage and Current Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity 3/4 S.No. Consignee Address Quantity Delivery Days 1 Sanjaya Kumar Patro 752050
National Institute of Science Education and Research NISER Campus Post Office Jatani 2 21
722667
GEM/2018/B/101989
Online UPS
21 days
Odisha; Khordha
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS ( PAC Only ) Experience with Gov. Required 3 Year (s) Online UPS ( 2 ) ( Under PAC ) Make numeric Model numerickeort Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 30.0 KVA * Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user 1/4 setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 48000 400-640000 Warranty for UPS (Years) 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without trollery but with rack With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP20 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt Yes * 2/4 age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity 3/4 S.No. Consignee Address Quantity Delivery Days 1 Sanjaya Kumar Patro 752050 | - | - | - |
| National Institute of Science Education and Research NISER Campus Post Office Jatani 2 21 | - | - | - |
Exempted
25 Oct 2018
11 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_722667.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .