Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAdmitted-Finance CHAMPAKNAGAR JIRANIA WEST TRIPURA PIN 799045 | WEST TRIPURA | TRIPURA | 799045 | ₹15.1 L | L1 | Admitted-Finance |
| 2 | L2₹17.6 L+₹2.5 L (16.8%)Admitted-Finance | ₹17.6 L+₹2.5 L (16.8%) | L2 | Admitted-Finance |
| 3 | L3₹17.7 L+₹2.6 L (17.4%)Admitted-Finance F A ROAD MACHKHOWA PO PS BHARALUMUKH DIST KAMRUP M ASSAM GUWAHATI 781009 | KAMRUP METRO | ASSAM | 781009 | ₹17.7 L+₹2.6 L (17.4%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical NOT AVAILABLE | - | - | Rejected-Technical Does not have appropriate b(i) category. |
| 5 | Rejected-Technical AZARA PO KAMRUP DIST GUWAHATI 781 015 ASSAM | KAMRUP METRO | ASSAM | 781015 | - | - | Rejected-Technical Does not have appropriate b(i) category. |
| Sl No | Description | Qty | Unit | MS DAS CONSTRUCTION L1 | M/s Hrishikesh Das L2 | M/S RAJA CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down old unservicable rolling shutter motor of input power 1013 watt and rated load of 1000 kg from existing postion,carring out major/minor repair like replacement of u/s bearing, break, cap, limit switch, gear box, driver gear including rewinding of motor and installing testing and commissioning of the same at original position complete all as specified and as directed.
Make of motor :- Jielong | 2 | Each Job | 6,500 ₹13,000 Lowest | 7,350 ₹14,700 | 9,375 ₹18,750 |
| 2.00 | M & L for repairing/servicing of electrically operated shutter operating mechanism at parking/storage areas of TP complex complete for both electrical as well as manual operation of the shutters, by checking/repairing of all the parts/systems, cleaning and tightening of all contacts & electrical connections, oiling/lubrication of the gears, bearing & chains etc, checking and properly tightening of all the hardwares, replacing worn out / rusted nuts/bolts/washers etc with new one, checking and setting the mountings for proper alignment and for smooth/trouble free opening/closing of the shutters, checking insulation value of the motor and testing the system for automatic (electric motor mode) and manual operation for trouble free opening and closing of the shutters complete all as specified and as directed. | 6 | Each Job | 4,700 ₹28,200 Lowest | 6,200 ₹37,200 | 7,750 ₹46,500 |
| 3.00 | Maintenance of existing APFC panel and cleaning of dust inside the cabinet with blower,cleaning of moving parts/contacts from CT cleaner, tightening of loose parts/electrical wires, cleaning of contactors, relays and capacitors junction points,servicing/oiling to cooling fan,complete testing of APFC relay with necessary setting with CTs/load adjustments to match with APFC load management system complete with replacement of worn out u/s components/burnt wire thimbles/lugs complete tested of cap up to 375 KVAR for following :- | 1 | Each Job | 19,900 ₹19,900 | 22,000 ₹22,000 | 19,500 ₹19,500 Lowest |
| 3.01(i) Rate of minor parts/components for replacement shall be included in the unit rate quoted. | ||||||
| 3.02(ii) APFC Panel should be attended throughly and servicing shall be done to the full satisfaction of the Engr-in-Charge.The payment shall be made after complete testing of the AFPC panel. | ||||||
| 3.03(iii) Replacement of small nuts/screws,burnt copper wires/lugs or thimbles/cleaning materials or CTC shall not be paid separately, the cost of these are deemed to include the schedule item rate. | ||||||
| 3.04(iv) The Following parts should be of the same make and capacity of existing one if which is required to be replaced complete all as specified and directed as supply only :- | ||||||
| 3.05 | (a) Supply only Controller | 1 | Each | 22,500 ₹22,500 Lowest | 24,200 ₹24,200 | 22,500 ₹22,500 Lowest |
| 3.06 | (b) Supply only Capacitor Bank 5 KVAR | 1 | Each | 6,500 ₹6,500 Lowest | 7,550 ₹7,550 | 9,350 ₹9,350 |
| 3.07 | ( c) Supply only Capacitor Bank 10 KVAR | 1 | Each | 7,500 ₹7,500 Lowest | 8,400 ₹8,400 | 10,550 ₹10,550 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
15 Aug 2026, 6:00 pmClosed
GE (P) AF Digaru
GE (P) AF Digaru PO Digaru Dist Kamrup Assam 782401
REPAIR AND MAINTENANCE OF METERING EQUIPMENTS, CHANGEOVER SWITCHES, DISPLAY SENSORS AND OTHER MISC WORKS AT AFS DIGARU
2026_MES_779621_1
C/8916/E8 of 2026-27
Open Tender
Miscellaneous Works
Item Rate
270 days
Digaru
Please ref Tender Documents
6 documents required · 6 mandatory
₹500
GE (P) AF Digaru
₹30,000
Yes
4 Sept 2026
18 Jul 2026
22 Aug 2026
18 Jul 2026
15 Aug 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old unservicable rolling shutter motor of input power 1013 watt and rated load of 1000 kg from existing postion,carring out major/minor repair like replacement of u/s bearing, break, cap, limit switch, gear box, driver gear including rewinding of motor and installing testing and commissioning of the same at original position complete all as specified and as directed.
Make of motor :- Jielong | 2 | Each Job | - | - |
| 2 | M & L for repairing/servicing of electrically operated shutter operating mechanism at parking/storage areas of TP complex complete for both electrical as well as manual operation of the shutters, by checking/repairing of all the parts/systems, cleaning and tightening of all contacts & electrical connections, oiling/lubrication of the gears, bearing & chains etc, checking and properly tightening of all the hardwares, replacing worn out / rusted nuts/bolts/washers etc with new one, checking and setting the mountings for proper alignment and for smooth/trouble free opening/closing of the shutters, checking insulation value of the motor and testing the system for automatic (electric motor mode) and manual operation for trouble free opening and closing of the shutters complete all as specified and as directed. | 6 | Each Job | - | - |
| 3 | Maintenance of existing APFC panel and cleaning of dust inside the cabinet with blower,cleaning of moving parts/contacts from CT cleaner, tightening of loose parts/electrical wires, cleaning of contactors, relays and capacitors junction points,servicing/oiling to cooling fan,complete testing of APFC relay with necessary setting with CTs/load adjustments to match with APFC load management system complete with replacement of worn out u/s components/burnt wire thimbles/lugs complete tested of cap up to 375 KVAR for following :- | 1 | Each Job | - | - |
| 3.01 | (i) Rate of minor parts/components for replacement shall be included in the unit rate quoted. | - | - | - | - |
| 3.02 | (ii) APFC Panel should be attended throughly and servicing shall be done to the full satisfaction of the Engr-in-Charge.The payment shall be made after complete testing of the AFPC panel. | - | - | - | - |
| 3.03 | (iii) Replacement of small nuts/screws,burnt copper wires/lugs or thimbles/cleaning materials or CTC shall not be paid separately, the cost of these are deemed to include the schedule item rate. | - | - | - | - |
| 3.04 | (iv) The Following parts should be of the same make and capacity of existing one if which is required to be replaced complete all as specified and directed as supply only :- | - | - | - | - |
| 3.05 | (a) Supply only Controller | 1 | Each | - | - |
| 3.06 | (b) Supply only Capacitor Bank 5 KVAR | 1 | Each | - | - |
| 3.07 | ( c) Supply only Capacitor Bank 10 KVAR | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
PS8916.pdf
Tender Documents • 1.17 MB
BOQ_873234.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .