Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.8 CrAccepted-AOC 201 MAJNAWAN FAIZABAD SADAR FAIZABAD 224001 | FAIZABAD | AYODHYA | UTTAR PRADESH | 224001 | ₹2.8 Cr | L-1 | Accepted-AOC 06SE 2025-26 |
| 2 | L-2₹2.9 CrRejected-Finance | ₹2.9 Cr | L-2 | Rejected-Finance L-2 |
| 3 | L-3₹2.9 CrRejected-Finance | ₹2.9 Cr | L-3 | Rejected-Finance L-3 |
| 4 | L-4₹3.1 CrRejected-Finance 584 BASANTPUR GEETA PRESS GORAKHPUR 273005 | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | 273005 | ₹3.1 Cr | L-4 | Rejected-Finance L-4 |
| 5 | L-5₹3.1 CrRejected-Finance | ₹3.1 Cr | L-5 | Rejected-Finance L-5 |
| Sl No | Description | Qty | Unit | SHREEASHOK L4 | M/S BABA TRADERS L5 | M/S V.K. CONSTRUCTION L1 | VIRAT CONSTRUCTION L3 | M/S ASHISH KUMAR PANDEY L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling brick work or cement mortar including stacking of materials as directed by Engineer in charge with a distance 60 M required for proper completion of the work. | 82.24 | cum | 380 ₹31,251.20 | 525 ₹43,176 | 502 ₹41,284.48 | 537.2 ₹44,179.33 | 500 ₹41,120 |
| 2.00 | Dismantling Existing Plaster including disposal of refuse as per Directed by Engineer-in-charge wthin a distance of 60M. required for proper completion of the work. | 17,137.47 | Sqm | 27 ₹4.6 L | 32 ₹5.5 L | 25 ₹4.3 L | 28.6 ₹4.9 L | 30 ₹5.1 L |
| 3.00 | Dismantling C.C. floor including disposal of refuse as direction by the Engineer-in -charge with in distance of 60 M required for proper completion of the work. | 106.87 | cum | 27 ₹2,885.49 | 48 ₹5,129.76 | 34 ₹3,633.58 | 40.23 ₹4,299.38 | 45 ₹4,809.15 |
| 4.00 | Dismantling Door/Window frames including Chaukhat with holdfast and including stacking of materials as directed by Engineer-in-charge required for proper completion of the work. | 583.33 | Sqm | 55 ₹32,083.15 | 52 ₹30,333.16 | 70 ₹40,833.10 | 67.94 ₹39,631.44 | 50 ₹29,166.50 |
| 5.00 | Dry earth work in foundation for Construction of building including lead up to 30M lift upto 1.50M and Back fill as required for proper completion of the work. | 78.54 | cum | 105 ₹8,246.70 | 88 ₹6,911.52 | 89 ₹6,990.06 | 102.81 ₹8,074.70 | 85 ₹6,675.90 |
| 6.00 | Laying C.C 1:3:6 in foundation with coarse sand F.M. more than 2 & brick aggregate of size 40 mm. including cost of all material labour and T&P etc. required for proper completion of the work. | 13.78 | cum | 7,100 ₹97,838 | 5,800 ₹79,924 | 4,300 ₹59,254 | 4,680.26 ₹64,493.98 | 5,000 ₹68,900 |
| 7.00 | Centering and shuttering for R.C.C 1:1.5:3 with all cost of material, labour and T&P etc. required for proper completion of the work. | 640.33 | Sqm | 640 ₹4.1 L | 800 ₹5.1 L | 700 ₹4.5 L | 759 ₹4.9 L | 500 ₹3.2 L |
| 8.00 | Supplying, cutting, bending,binding and placing in position of Tor steel for R.C.C. work including cost of all material, labour,T&P etc required for proper completion of the work. | 14.78 | MT | 64,500 ₹9.5 L | 75,000 ₹11.1 L | 70,000 ₹10.3 L | 68,448 ₹10.1 L | 73,000 ₹10.8 L |
| 9.00 | R.C.C. 1:1.5:3 with Cement, Coarse sand with F.M. more than 2 & Stone Grit 4.75mm. to 20.00mm. including cost of all material, labour and T&P. etc.required for proper completion of the work. | 181.01 | cum | 8,200 ₹14.8 L | 11,000 ₹19.9 L | 10,600 ₹19.2 L | 10,658.98 ₹19.3 L | 9,000 ₹16.3 L |
| 10.00 | R.C.C. 1:1.5:3 with Cement, Coarse sand & Stone Grit 4.75mm. to 20.00mm and Murga jali including cost of all material, labour and T&P etc required for proper completion of the work. | 60.53 | cum | 8,200 ₹5.0 L | 11,000 ₹6.7 L | 10,600 ₹6.4 L | 11,543 ₹7.0 L | 9,000 ₹5.4 L |
Tender Value
₹3.3 Cr
EMD Value
₹6.6 L
Closing Date
20 Feb 2026, 2:00 pmClosed
Superintending Engineer
SUPERINTENDING ENGINEER XVTH CIRCLE, IRRIGATION WORKS GONDA (U.P)
Repair work of Type-1, Type-2, Type-3 and Type-4 houses located in Saryu Canal Colony District-Ayodhy
2026_UPIDC_1115588_5
06/SE/2025-26 SNK AYODHYA
Open Tender
Civil Works
540 days
AYODHYA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,654
₹6.6 L
GONDA
28 Apr 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
13 Feb 2026
Dismantling brick work or cement mortar including stacking of materials as directed by Engineer in charge with a distance 60 M required for proper completion of the work.
Dismantling Existing Plaster including disposal of refuse as per Directed by Engineer-in-charge wthin a distance of 60M. required for proper completion of the work.
Dismantling C.C. floor including disposal of refuse as direction by the Engineer-in -charge with in distance of 60 M required for proper completion of the work.
Dismantling Door/Window frames including Chaukhat with holdfast and including stacking of materials as directed by Engineer-in-charge required for proper completion of the work.
Dry earth work in foundation for Construction of building including lead up to 30M lift upto 1.50M and Back fill as required for proper completion of the work.
Laying C.C 1:3:6 in foundation with coarse sand F.M. more than 2 & brick aggregate of size 40 mm. including cost of all material labour and T&P etc. required for proper completion of the work.
Centering and shuttering for R.C.C 1:1.5:3 with all cost of material, labour and T&P etc. required for proper completion of the work.
Supplying, cutting, bending,binding and placing in position of Tor steel for R.C.C. work including cost of all material, labour,T&P etc required for proper completion of the work.
R.C.C. 1:1.5:3 with Cement, Coarse sand with F.M. more than 2 & Stone Grit 4.75mm. to 20.00mm. including cost of all material, labour and T&P. etc.required for proper completion of the work.
R.C.C. 1:1.5:3 with Cement, Coarse sand & Stone Grit 4.75mm. to 20.00mm and Murga jali including cost of all material, labour and T&P etc required for proper completion of the work.
Providing & Laying DPC 25 mm Thick With CC 1:2:4 with 10 mm size graded stone grit required for proper completion of the work.
Ist Class Brick Work with using class 150 bricks in 1:4 CM Cement and Coarse Sand including all cost of material, labour and T&P etc. required for proper completion of the work.
12mm. Thick cement plaster in 1:4 CM with coarse sand including all cost of material, labour and T&P etc required for proper completion of the work.
Laying C.C.(M-20) 1:1.5:3 with Cement, Coarse sand with F.M. more than 2 & Stone Grit 4.75mm. to 20.00mm. with all cost of material, labour and T&P. etc.required for proper completion of the work.
Providing & laying floor tiles in 600X600 mm.size (thickness to be specified by the manufacurer) with water absorbtion less than 0.08% & confirming to IS15622 of approved make in all colours and shades laid on 20mm. Thick cement mortor 1:4 CM & Coarse sand Jointing with grey cement slurry @3.3Kg./ Sq.m. including grouting the joint with white cement and matching pigments etc. required for proper completion of the work.
Providing and Laying rectified Glazed Ceramic Floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st Quality conforming to IS 15622 of approved make, in colours white lvory, grey, fume, red, Brown, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand ), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement and matching pigments etc.required for proper completion of the work.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade required for proper completion of the work.
Providing and applying cement based putty on average thickness of 1mm.of approved brand and manufacture over wall shurface to prapare the surface even and smooth required for proper completion of the work.
Finishing walls with premium acrylic smooth exterior paint with silicon additives of required shade. New work (two or more coat applied @1.43 ltr/10sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (apex ultima, weather coat all quard) asian berger required for proper completion of the work.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work (ist quality (Royal, silk )Asian / berger) required for proper completion of the work.
Fabrication of Mild Steel/ Iron Work in Grill , Gates Railing, Door and Window frame including cutting, drilling, welding/ riveting and hinges where ever necessary and fixing in position including all cost of material and T&P. required for proper completion of work with one coat of Red Oxide Primer.required for proper completion of the work.
Providing and fixing 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters required for proper completion of the work.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm . As per DSR 2023 Item 9.100.1 required for proper completion of the work.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm. As per DSR 2023 Item 9.100.2 required for proper completion of the work.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm required for proper completion of the work.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 200x10 mm . As per DSR 2023 Item 9.97.3 required for proper completion of the work.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 150x10 mm . As per DSR 2023 Item 9.97.4 required for proper completion of the work.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper. As per DSR 2023 Item 9.101.2 required for proper completion of the work.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm. 9.135.1 required for proper completion of the work.
Making hole in wall for exhaust fan and finishing properly complete in all respect as per PWD item no.-1121 required for proper completion of the work.
Supply & Fixing Exhaust Fan Size 300mm required for proper completion of the work.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required for proper completion of the work.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. As per DSR 2022 E&M Item 1.14.1 required for proper completion of the work.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. As per DSR 2022 E&M Item 1.14.2 required for porper completion of the work.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. As per DSR 2022 E&M Item 1.14.3 required for proper completion of the work.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.15/16 A switch As per DSR 2021 E&M Item 1.24.3 required for proper completion of the work.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required.6 pin 15/16 A socket outlet As per DSR 2021 E&M Item 1.24.5 required for proper completion of the work.
Supplying and fixing following Size/modular GI box along with modular base and cover plate for modular switeches in racess etc. as required for proper completion of the work.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required for proper completion of the work.
Supplying and fixing PVC batten/angle holder including connection etc as required for proper completion of the work.
Installation, testing, commissioning of wall bracket/celling fittings/Fan of all size. etc required for proper completion of the work.
Supplying and fixing Electronic fan Regulator of approved quality. including connection etc as required for proper completion of the work.
Supplying & Fixing of Fluorescent single tube LED type fitting duly wired etc of approved make required for proper completion of the work.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker single pole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required for proper completion of the work.
Supplying and fixing following rating, double pole, 240 V, 63A isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required for proper completion of the work.
Supply & Fixing of 100W L.E.D. steet light with appropriate fixtures and nacessary connection etc. complete.As per Market Rate required for proper completion of the work.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge required for proper completion of the work.
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge required for proper completion of the work.
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape,size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge required for proper completion of the work.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge required for proper completion of the work.
P/F 10 Litre capacity low level PVC cistern of standard approved make complete with all accessories and fitting required for proper completion of the work.
Cutting chases in brick masonry walls for pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) 100 mm dia metre required for proper completion of the work.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. required for proper completion of the work.
P/F sand cast iron floors trap of self cleansing design, screwed down with hinged grating with or without vent arm including cost of cutting and making good the walls and floors required for proper completion of the work.
Providing and fixing soil, waste and vent pipes100 mm dia hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 required for proper completion of the work.
Providing and fixing soil, waste and vent pipes75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 required for proper completion of the work.
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside &outside as per IS:15905 required for proper completion of the work.
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 required for proper completion of the work.
Providing and fixing terminal guard :100 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 required for proper completion of the work.
Providing and fixing plain bend of required degree.100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 required for proper completion of the work.
Providing and fixing plain bend of required degree. 75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 required for proper completion of the work.
Providing and fixing double equal plain junction of required degree.100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 required for proper completion of the work.
Providing and fixing double equal plain junction of required degree.75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 required for proper completion of the work.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes metre required for proper completion of the work.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20mm nominal dia Pipes metre required for proper completion of the work.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes metre required for proper completion of the work.
Providing and fixing wash basin 550x400 mm with single hole/number of holes for pillar tap with CI or MS brackets painted white including cutting holes and making good the same but excludinf fittings required for proper completion of the work.
Providing and fixing pedestal for wash basin completerecessed recessed at the back for the reception of pipes and fittings required for proper completion of the work.
Providing and fixing 15mm PVC connection 45 cm length, heavy quality with brass union including supply of materials,labour,T&P etc. required for proper completion of work.
P.T.M.T. extension nipple 15 mm dia.required for proper completion of the work.
Providing and fixing C.P. brass waste pipe for sink or wash basin 32mm dia with cost of material, Labour,T&P etc required for proper completion of the work.
Providing and fixing 100mm dia C.P. shower rose with 15mm/20mm inlet required for proper completion of the work.
Providing and fixing M.S. stays and clamps for sand cast iron /centrifugally cast (spun) iron pipes of diameter. For 100 mm dia pipe required for proper completion of the work.
Providing and fixing M.S. stays and clamps for sand cast iron /centrifugally cast (spun) iron pipes of diameter. For 75 mm dia pipe required for proper completion of the work.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards 15 mm nominal bore required for proper completion of the work.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore required for proper completion of the work.
S.C.I. gully or nahani grating 100 mm dia required for proper completion of the work.
Providing and fixing Stainless Steel kitchen sink 610x510x178 with C.I. brackets excluding cost of other fittings required for proper completion of the work.
Electronic Type Chlorinating dosing System (1W+1S) With 6 LPH Capacity 4kg / cm2 working pressure with 2 No 100 Litres tank and valves pipes with all required accessories required for proper completion of the work.
Excavation of earth in ordinary soil (loan clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 M and refilling watering ramming if the excavated earth into the trench and also disposal of surplus earth upto 50 M from the center of the trenches including suppl of all material labour T&P etc complete as per instruction of Engineer in charge required for proper completion of the work.
Supply of following size Pipes for Distribution System Conforming to latest/relevant I.S.4984/1995 Specification with all jointing materials and Specials conforming to latest / relevant IS. Specifications. including F.O.R destination and all taxes and insurance etc. with loading unloading and carting up to site of work also including specials for these pipe and lowering them in to the trenches and laying true to alignment and gradient and jointing etc. complete( including testing of pipe lines and cutting of pipe for making up to the length but excluding the cost of trenches) all complete as per instruction of Engineer in charge.90 mm dia HDPE Pipe PN-6: Class PE-100 required for proper completion of the work.
Supply of following size Pipes for Distribution System Conforming to latest/relevant I.S.4984/1995 Specification with all jointing materials and Specials conforming to latest / relevant IS. Specifications. including F.O.R destination and all taxes and insurance etc. with loading unloading and carting up to site of work also including specials for these pipe and lowering them in to the trenches and laying true to alignment and gradient and jointing etc. complete( including testing of pipe lines and cutting of pipe for making up to the length but excluding the cost of trenches) all complete as per instruction of Engineer in charge.110 mm dia HDPE Pipe PN-6: Class PE-100 required for proper completion of the work.
Supply of following size Pipes for Distribution System Conforming to latest/relevant I.S.4984/1995 Specification with all jointing materials and Specials conforming to latest / relevant IS. Specifications. including F.O.R destination and all taxes and insurance etc. with loading unloading and carting up to site of work also including specials for these pipe and lowering them in to the trenches and laying true to alignment and gradient and jointing etc. complete( including testing of pipe lines and cutting of pipe for making up to the length but excluding the cost of trenches) all complete as per instruction of Engineer in charge.125 mm dia HDPE Pipe PN-6: Class PE-100 required for proper completion of the work.
Supply and carting up to site of work of the following dia DI butterfly / Sluice valves class 1 working pressure 10 Kg /cm2 confirming to IS: 780 /1969 or its latest amendments including valve fitting & Dismantling joints as per requirement F.O.R destination and lowering them into the already prepared trenches fixing in position and jointing them with pipelines and testing etc. complete and also including supply of jointing materials etc. compete. incuding all taxes and insurance as per instruction of Engineer -in-charge.Sluice valves 100 mm dia required for proper completion of the work.
Supply and carting up to site of work of the following dia DI butterfly / Sluice valves class 1 working pressure 10 Kg /cm2 confirming to IS: 780 /1969 or its latest amendments including valve fitting & Dismantling joints as per requirement F.O.R destination and lowering them into the already prepared trenches fixing in position and jointing them with pipelines and testing etc. complete and also including supply of jointing materials etc. compete. incuding all taxes and insurance as per instruction of Engineer -in-charge.Sluice valves 150 mm dia required for proper completion of the work.
Supply and carting up to site of work of the following dia DI butterfly / Sluice valves class 1 working pressure 10 Kg /cm2 confirming to IS: 780 /1969 or its latest amendments including valve fitting & Dismantling joints as per requirement F.O.R destination and lowering them into the already prepared trenches fixing in position and jointing them with pipelines and testing etc. complete and also including supply of jointing materials etc. compete. incuding all taxes and insurance as per instruction of Engineer -in-charge.Sluice valves 80 mm dia required for proper completion of the work.
Supply of Under ground sluice value type fire hydrant consisting of 80 mm dia sluice valve 80 mm dia tail pieces 80 mm dia duck foot bend and 80 mm dia standred makes iron couping with cap and etc. compete conforming to latest/relevent I.S apecifications including all taxes and insurance up to site of work and lowering them into the trenches fixing in position and jointing them with pipeline and testing etc. complete (including supply of jointing matreial and valve fitting etc. compete as per instruction of Engineer- In Charge required for proper completion of the work.
Provision for inter connection from old existing pipe line with new pipe line as per requirement & Direction of Engineer-in-charge. Including suppl of all maetrial labour T&P etc.140 mm dia x 125 mm dia or below dia required for proper completion of the work.
Provision for inter connection from old existing pipe line with new pipe line as per requirement & Direction of Engineer-in-charge. Including suppl of all maetrial labour T&P etc.125 mm dia x 90 mm dia or below dia required for proper completion of the work.
Contruction of Single tap pillar type stand post as per type desing required for proper completion of the work.
Complete cabling for tubewell including all power and control cables of all equipments at pumphouse and OHT required for proper completion of the work.
Spare pump of 7.5 HP submercible capacity required for proper completion of the work.
Supply & Fixing of Automatic Air Break Star Delta Starter Panels 7.50 HP /12.50 HP required for proper completion of the work.
Supply & Fixing of TPN Switch 100 Amp required for proper completion of the work.
Cleaning of OHT. Including Cleaning materials, Labour T&P required for proper completion of the work.
Wall Painting with plastic emulsion paint of approved brand and manufacture to give and even shade. One or more cots on old work (Royal, silk) asian/baerger) required for proper completion of the work.
Making house Connection should be done atleast 2 m inside the boundary wall with provision of tap from distribution line to outer wall of house with supply of 1 m above GL GI. Pipe (15mm) (above ground) & average 5 Mtr. MDPE pipe (20mm) (Below grond) including specials saddle, Tap, Ferrule / FCV etc. of suitable size T&P etc. including excavation laying and jointing for proper completion of work as per instruction of Engineer as per Dwg 12 (Excluding road restoration) required for proper completion of the work.
Construction of following type chambers as per department type design and drawing. Including heavy duty M.S manhole cover and all material labour T&P etc complete for proper completion of work as per instruction of Egineer-in- chargeSluice Valve chamber (masonry type), dia upto 200 mm-1000(L) x 1200 (W) x 1300 (H) mm required for proper completion of the work.
Construction of following type chambers as per department type design and drawing. Including heavy duty M.S manhole cover and all material labour T&P etc complete for proper completion of work as per instruction of Egineer-in- charge Fire Hydrant Chamber (750(L)x450(w)x1000 (h) mm) required for proper completion of the work.
Dismantlling and Rainstatement of the following type of road surface with old and new materials . Including supply of all material labour T&P etc. required for proper completion of the work as per instruction of Engineer- in Charge.Interlocking Road (50% of existing paver block to be reused) required for proper completion of the work.
Painting two coat of synthetic enamel paint on new surface with superior quality approved make as mentioned in Item 11 including cost of all material labour T&P etc. required for proper completion of work.
Painting two coat of superior quality of synthetic enamel paint approved make as per Item No.12 on new wooden surface (excluding cost of primary) including cost of all material, labour T&P etc. required for proper completion of work.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.11 MB
BOQ_2070304.xls
BOQ • 0.35 MB
Lot5.pdf
Tender Documents • 2.36 MB
Download all tender documents and submit your bid