Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance SR NO 165 OPPOSITE YASH HOSPITAL DP ROAD MALWADI PUNE MAHARASHTRA 411028 | PUNE | MAHARASHTRA | 411028 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
29 Mar 2021, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R AND D GIRINAGAR
GE I R AND D GIRINAGAR
RENOVATION OF QUANTUM COMPUTING SIMULATION LAB AT POINTS BLDGS DIAT DU GIRINAGAR PUNE
2021_MES_429039_2
GE I R AND D GNR TOKEN 61 OF 2020 21
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE I R AND D GIRINAGAR
₹64,000
Yes
30 Mar 2021
23 Mar 2021
30 Mar 2021
23 Mar 2021
29 Mar 2021
24 Mar 2021
23 Mar 2021 - 23 Mar 2021
60 days
Amount
PART-I ADDN/ALTN (B/R PORTION) Dismantling wrought iron or mild steel work of any description.
Taking down chowkats or frames of wooden exc 1.5 sqm & n.exc. 4 Sqm with Shutters (without taking off shutters from the frames).
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removal of debris outside MD land all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises.
Hacking out glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and removed from patent glazing clips
Taking down Prelaminated particle board (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and removed from patent glazing clips
Dismantling powdercoated aluminium frame work of any height including removing from outside MD land
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
Demolition of Brickwork or stone/boulder masonary, built in Cement mortar
M&L for Brickwork with flyash bricks straight or curved on plan exc 6m mean radius built in CM 1:6
M&L for Rendring 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls ,finishing surfaces even and smooth w/o using extra cement.
Forming jambs etc to opening including cutting toothing and properly bonding into old work including facing and pointing (if necessary) to match existing work complete in CM 1:4
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for doors , windows, ventilators, partition wall etc. with one or more rebates, shutters, grills including joining cleat glazing clips for fixing etc. complete all as specified.
S&F anodized aluminium door shutters aluminium section weighing 0.55kg/m including necessary joining cleat glazing clip, rubber neoprene packing, handles 2 no in each door, hinges, anodised aluminium snap beading screws etc complete all as specified. including Powder coating of any colour (Thickness of powder coating not less than 50 Micorn)
M&L for Powder coated aluminium window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section wighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, Handle, lock, powder coated aluminium snap beading scres etc complete
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18mm & fixed with stainless steel wire staples all as specified.
M&L for Framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290.Gde-E-165 for MS framed work as in trusses, purlins, rafters, post etc conforming to grade E-250 (Fe 410W, quality 'A') including shaped washers, including necessary cutting required length, notching, drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plate, gusset plate and also erecting in true position complete as directed.
Preparation of new decorated Steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer.
S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame work .
M&L for Sheet glass, ordinary quality, in squares exc 0.5 sq. m each pane 4mm Thk in doors, in partition
M&L for solar control film 25micorn relfective type sticked to glass panes as per insturction of manufactureres
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints supplied and fixed
S&F for holdfast confirming to Fe 290 Gde E-165
M&L for PCC 1:2:4 type B1 (20mm Graded stone aggregate) as in filling in frame and bed block for fixing of holdfast fo door frame.
S & F Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides 40mm Thk
S&F Decorative Laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive to Plywood as per manufacturers instruction.0.9mm Thick
Preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink Primer
Preparing surfaces of wood and wood based materials, steel and iron work, new or old of any description and girth not otherwise described and treated with tar or coal tar black paint
M&L Aluminium (Extruded section) body Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
M&L for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty and fixed
M&L for 125mm high butt hinges heavy weight cold rolled mild steel and fixed
S&F brass sliding door bolts with sand or die cast brass hasp and staple (Bolt Type) and fixing bolt with rolled or drawin brass bolt and fixed length of bolt 250mm
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F Brass handles, polished type, of size 150 mm
M&L for formwork to sides and soffits of lintel beam, floor or roof beam etc
M&L for RCC Nominal Mix Type B1 1:2:4 (20mm Graded aggregate) concrete in lintel beam, cantilever etc
S&F TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns hooking ends and bindng with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Same as per item above but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders
M&L for hangers 3mm dia GI adjusting level fixed to roof slab/steel truss by means of ceiling cleats made out of GI flat 40X3mm size 60mm long.
M & L for treating the top surface of filled earth and soil under plinth protection at the rate of 5 Ltrs of anti termite emulsion per Sqm of surface.
M & L for cement concrete type D-2 1:4:8 (40mm graded aggregate) 75mm thick
M&L for glazed coloured vitrified tiles 600x600x10mm thick as in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles, laid over and including 20mm thick backing coat in CM 1:4 all as specified and directed by Engr-in-Charge.
S & F Machine cut cuddappa stone slab one side polished 20 to 25mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 20mm screed bed in cement mortar (1:6) .
M & L for granite 18mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Rounding edges of stone one edge, such as in steps, cooking platform, window cill and other similar situation.
M&L for 4mm thick Prelam glossy finish PVC sheet in strips & channel feathered at the edges for fixing on solid PVC wall, Insulated PVC wall lining and Soild PVC Partition inclusive of solvent and fixed at site in Aluinium framework.
S&F in repairs PVC (SWR) floor trap, dia of outlet 75mm, plain with grating including jointing with solvent cement.
S&F 15mm dia Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc any type of pipe
S&F 20mm dia Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc any type of pipe
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting n.exc. 10cm girth.
S&F stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe of for unions of bore 15mm complete all as specified.but fancy type, chromium plated
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or cudappah stone or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm inlcluding 40mm waste coupling and waste pipe
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed but fancy type chromium plated
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors of size 110mm bore complete all as directed.
S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floor of 75mm bore
S&F PVC (SWR) bends any radius 110 mm bore with access door
S&F PVC (SWR) Gulley Trap 125/100mm, setting and jointing with solvent cement.
S & F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 20mm bore.
S&F ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20mm bore.
S&F PVC water storage tank 1000 Litrs capacity ISI marked rotational moulded double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of 500 ltrs capacity.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation and getting out in Hard/dense Soil
Removing excavated soil n exc 250m but N Exc 500m and depositing where directed.
M&L for cement concrete1:4:8 type D2 as in foundations filling and mass concrete
M&L for brickwork with sub class 'B' bricks in half brick thick honey comb walling built in CM 1:4
M&L for cutting holes of superficial area Exc 150Sqcm but N Exc 400 Sqcm into or through brick walls built in cement mortar or cement lime mortar and stone walls built in cement mortar or cement lime mortar and walls or cement concrete
M&L for precast RCC (1:2:4) type B1 (using 20mm graded stone aggregate), in cover slabs of manholes, open drains inclusive of form work set in CM (1:4) complete all as specified. (Reinforcement shall be measured and paid separately).
PART -I B/R PORTION (SPL ITEMS) S&F of 600X600X0.7mm thick powder coated aluminium tile square tegular with semi concealed grid. The tile shall be laid on semi concealed grid system with 15 mm white flange incorporating 6 mm central reveal in white/black colour and with web height of 38 mm and load carring capacity of minimum 11.68 kg/sqm.Silhouette. main runner and cross tees to have mitred ends & birdmouth notches to provide mitred cruciform junction. The T sections have galvanising of 120 gms/sqm ( Make : armstrong, saint Gobain)
M&L 2nd class hardwood with sectional area Exc 6 Sqcm & N Exc 13 Sqcm for plain fillets square, rectangular or triangular in section, clean sawn, secured with screws
M&L for preparing surfaces or wood and wood based materials, new or old , of any description and girth, not otherwise described and treated with creosote.
M&L for 12mm thick with 7 No of Ply Plywood, grade BWE, type BB, fixed with screws to timber frame work.
M&L for 3mm thick veneers of any type and texture fixed to plywood with nails
M&L for glossy finish Melamine polish with PU Coating by deco spray after completion of polish including preparation of surfaces, filler coat etc
S&F Venition blends with design on inner face verticle type made out of fibre cloth fixed, to wall with necessary Aluminium brackets, screws etc including Alluminium frame for venilion blinds rolling type etc all as approved by GE all as specified and directed.
M&L for Magnetic white board of 6mm Thick Overall size shall be 1.8m X 1.2m High Fixed to wall complete all as specified.
M&L for 1.8X1.2m high 25mm Thick wooden blackboard covered with 6mm thick rough glass which give rough surface while writing including glossy melamine polishing to exposed surface, necessary fitting fixture as required for fixing to wall complete all as specified.
M&L for preparing of new surfaces wall applying two coats of OBD, white or tinted, over 3mm thick wall care putty and including primer all as directed .
PART-I ADDN/ALTN (E/M PORTION) Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for making good disturbed surfaces of walls, floors and roofs etc all as specified and as directed.
Taking down sub main wiring complete including fitting and fixtures, removing materials and making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed.
Taking down carefully unserviceable DBs any type/size With MCCBs/Isolator etc and disconnecting and making good disturbed surfaces complete all as directed.
M & L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates, modular flush boxes and modular frame for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed for the following: - (a) One light point controlled by one way switch.
(b) One fan point controlled by one switch.
(c) One 3 pin switch socket outlet point 5 Amps on independent board.
(d) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch, single pole,one way 6 Amps capacity
S & Fix modular switch, single pole, one way 16 Amps capacity
S & Fix modular socket, outlet 2 in 1, 6 Amp capacity
S & Fix modular, socket 6A/16A 2 in1, 16 Amp capacity
S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix modular fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts, 4 step complete all as directed.
S & Fix LED efficient recessed mounting fitting 2' X 2' luminaire to enhance the delight of occupents with comfortable experience through its classic design & glare free soft illumination all as specified & directed Make - Bajaj Cat Part No - BZRSQL 36L LED GX D WH SD or eqvt in Wipro/Havell/Crompton.
S & Fix MCCB DB VTPN 8 ways, with metal double door ,IP -43 protection suitable for MCCB as incommer and MCB as out going, VTPN DB's 415 volt 3 phase complete with appropriate size copper bus bar and neutral link as required at site and including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e directed by Engr-in charge.Make : Legrand or eqvt make of ABB/Siemens
S & Fix sheet metal enclosure distribution board SPN 8 way 240 volts, 100 amp busbar rating with IP 43 protection and double door, suitable for mounting MCBs and including concealed of the DBs in wall all as specified and as directed.
S & Fix sheet metal enclosure distribution board SPN 12 way 240 volts, 100 amp busbar rating with IP 43 protection and double door, suitable for mounting MCBs and including concealed of the DBs in wall all as specified and as directed.
S & Fix MCB single pole, 240 volts, 6 to 40 Amps, all as specified and as directed.
S & Fix MCB single pole & neutral, 240 volts, 32 to 63 Amps, all as specified and as directed.
S & Fix MCB Triple pole & neutral, 240 volts, 40 to 63 Amps, all as specified and as directed.
S & Fix of MCCB Four pole, 415 volts, 125 Ampere, rupturing capacity 16 KA, complete all as specified and directed.
S & Fix LAN socket connecter RJ45 with socket with copper feed modular type all as directed by Eng in Chrage.
S & Fix LAN cable 4 pairs PVC insulated and PVC sheathed all as directed by Engr in Charge
S & Fix for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the concealed conduit and including suitable size of PVC conduit fixed to walls / roofs / floors / ceiling etc with its accessories all as specified and directed by Engr-in -charge for the following. (a) 2x4 sq mm and 1x4 sq mm as earth wire
(b) 2x6 sq mm and 1x6 sq mm as earth wire
(c) 4x6 sq mm and 1x6 sq mm as earth wire
Taking down and refixing of Ceiling fan any size/sweep, including oiling, Greasing and cleaning and applying two coats of synthetic enameled paint after preparation of surface complete over a coat of primer.
S & Fix Ceiling fan complete with all accessories 230 Volts,1200 mm sweep (white colore), BLDC 5 star rated complete with all fixing arrangement to ceiling and roof etc all as specifide & directed .make : Havelles, Bajaj and Usha .
S & Fix for ceiling fan down rods 1.2 M Long of 15 mm dia GI pipe to the existing trusses of any height including necessary welding & fixing with clamps and nut bolts etc complete all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordlessremote control unit and with in built air ioniser and Plasma filter for better indoor air quality, Refrigerent R-32 with inverter technology of capacity 1.5 TR, Make :- Voltas / Carrier.
S & Fix Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCBs with 240 V 20 AMPs MCBs.
S & Fix suction and discharge copper tubing pipe 3/8" and 5/8" for split type AC including provision of insulation on tubing, PVC insulated flexible multistranded copper cable 3 core 2.5 sqmm all as directed by Engr-in-charge.
S & Fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilized at 230 volts with accuracy +/- 2.5% and of capacity 4 KVA, Make :- V Guard / M Guard
Cutting holes by core cutting machine or other mean into or through cement concrete slabs, chajjas, reinforced or otherwise, brick / stone masnary walls etc. cutting area n. exe. 100 sqcm and making good disturbed surfaces
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less that 1.5 M below normal grouond level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe withand funnel, PCC 1:3:6 Type C-1 chamber with 40mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
PART-I (SPL ITEM)E/M PORTION Supply and fix UPS 20 KVA (3-3), Input 3 Phase, 380VAC / 400VAC (3Ph + N) Acceptable Voltage range - 285 VAC - 475 VAC Frequency range - 50Hz / 60 Hz +10% overall efficiency (AC Mode) - 91%, Efficiency (Battery Mode) 91%, Battery type - SMF type, 12 V, 100 AH- 30 Nos of battery, Make - Exide, Operating temperature :- 0 - 50ºC, Humidity - 0 - 90% (non condencing) Noise level - less than 60 dBA @ 1 meter, Output : 3 x 380/400VAC +/- 1% (3Ph +N), 415 VAC (Adjustable), Frequency range - 50 Hz +/- 1%, Power facter - 0.8, Overload capacity 110% for 10 minute. Make - Microtek - i - MAXX SERIES or equivalent approved make.
PART-I EXTERNAL ELECTRIC SUPPLY (E/M PORTION Supply and Laying in trenches LT underground cable ISI marked XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc, laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole,making hole in wall as per requirement at site complete all as directed by Eng-in-charge of following:- (a) 3.5 core 25 Sqmm
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
M &L for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engr-in-Charge.
M &L for GI pipe medium grade, for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA a) 50 mm dia
J.G.Goel
Samyak Engineers
M/S P D TUPE
Aakar Constructions
S.K.HARAL
M/S Narendra Construction
SUN Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .