| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.0 L+₹1.7 L (7.98%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹24.9 L+₹3.5 L (16.6%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹27.8 L+₹6.5 L (30.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to No in CE Leh Zone WLR for QE Mar 2021 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
3 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HQ 134 WKS ENGRS
HQ 134 WKS ENGRS PIN-914134 C/O 56 SPO
SPECIAL REPAIR TO SPECIALIST VEH PARKING AREA AND AVN OIL AND LUBRICANT STORAGE SHED AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2021_MES_457685_1
134 WE-10/2021-22
Open Tender
Civil Works
Item Rate
180 days
SRINAGAR
PLEASE SEE TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) CIF (K)
₹64,000
Yes
7 Sept 2021
6 Jul 2021
5 Aug 2021
6 Jul 2021
3 Aug 2021
21 Jul 2021
60 days
Amount
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engr-in-Charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed by the Engr-in-Charge.
Taking down cement plaster on brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for 15mm thick rendering in CM 1:4 on other than fair faces of brick/concrete surfaces for any description and finished even and fair without using extra cement complete all as specified or directed by the Engr-in-Charge.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick/concrete surfaces for any description and finished even and fair without using extra cement complete all as specified or directed by the Engr-in-Charge.
M&L rendering 10mm thick in cement plaster 1:3 on ceiling surface finished even and smooth without using extra cement.
Preparation of newly plastered surfaces of wall & applying two coats of cement base paint over one coat of alkali primer including necessary scaffolding etc complete all as specified and directed.
Preparation of newly plastered surfaces of wall and apply two coats of distemper oil emulsion (OBD) over a coat of cement wall primer (from same manufacturer of OBD) over a layer of wall care putty not less than 3mm thick etc complete all as specified and directed.
M&L for Preparation of new or previously untreated surface on Ceiling and applying three coats of white wash, complete all as specified and directed by Engr-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposed of unserviceable materials, debris and rubbish to a distance not exceeding 100m as directed by the Engr-in-Charge.
Demolition of un-reinforced cement concrete of any position not otherwise specifically provided for including disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m as directed by the Engr-in-Charge.
PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) in surface channels and drains as directed by Engr-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement, including forms moulds, mitred/ stopped end etc complete all as specified and directed by the Engr-in-Charge.
M&L for 75mm thick, PCC, (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection , finishing cement concrete surface even and smooth without using extra cement including joints filling with sealing compound Grade 'A' complete all as specified and directed by Engr-in-Charge.
M&L for 100mm thick, PCC, (1:4:8), type D-2 (using 40 mm graded crushed stone aggregates) as in sub base of flooring without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 75 mm thick PCC 1:2:4 type B-1 ( using 20 mm graded stone aggregate) as in hard standing finished and fair without using extra cement,all as specified.
M&L for Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'B' in 100 mm thick concrete complete all as specified and directed
M&L for Forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'B' complete all as specified and directed
Dismantling wrought iron or mild steel work of any description of any description not otherwise provided for complete all as specified and directed by the Engr-in-Charge.
S&F Rolled sections as in main and cross beams, hip, and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates Fe-410-W (Gde-250) quality -B complete all specififed and directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise, described, over 10cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge.
Pre- painted galvalume aluminum zinc coating GI based plain steel sheet, 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
Taking down carefully unsv/damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc) and removing material from site and making good to the disturbed surface to match with existing finish etc complete all as specified and directed.
Point wiring using FR PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FR PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bend, junction box and pressed steel sunken box 60 mm deep & 1.6 mm thick duly painted inside and anticorrosive out side for mounting switches, sockets, fan regulators etc with 3mm thick plastic laminated sheet cover of suitable size, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point etc complete all as specified and directed. (Note : Switch/bell push/fan regulator etc shall be measured and paid separately)
All as per above item No 26 but here-in-before 5 PIN socket out let 5 Amp on the independent board complete all as specified and directed by Engr In Charge
All as per above item No 26 but here-in-before 5 PIN socket out let 5 Amp on the same board complete all as specified and directed by Engr-in -Charge
All as per above item No 26 but here-in-before 5 PIN socket out let 15 Amp on the independent board with 2.5 sqmm for phase and neutral and 2.5 sqmm for earthing complete all as specified and directed by Engr In Charge
Sheet metal enclosure factory made (double door) shutter type for DB, SPN 8 ways , 240 Volts with 200 Amps rated bus bar, neutral link, earth bar complete all as specified and directed by Engr-in-Charge.
Sheet metal enclosure factory made (double door) shutter type for DB, SPN 4 ways , 240 Volts with 200 Amps rated bus bar, neutral link, earth bar complete all as specified and directed by Engr-in-Charge.
S&F MCB SPN 32 Amps, 10KA, 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F MCB SPN 6 to 32 Amps, 10KA, 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F Switch piano, flush type, 5 Amp, One way, complete all as specified and directed by Engr-in-Charge.
S&F Socket outlet 2-in-1, 3 pin, 5 Amp, 230V complete all as specified and directed by Engr-in-Charge.
S&F Switch piano, flush type, 15 Amp, complete all as specified and directed by Engr-in-Charge.
S&F Socket outlet 2 in 1, 5 & 15 Amp, 230Volts flush type, complete all as specified and directed by Engr-in-Charge.
Ceiling rose 3 terminal size 50 x 65 mm surface type, complete all as specified and directed by Engr-in-Charge.
S&F LED Decorative altra slim linear Tube Light 20 watt complete Make : LHEXBHP7PN1W020 of Havells or equivalent in Bajaj/ Crompton Greaves/ Philips
1100 volt grade XLPE insulated heavy duty cable 10 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable etc complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Supply, fixing and laying GI Pipe light grade 25 mm bore for protection of cable in trenches/under road complete, all as specified and directed by Engr-in- Charge.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for laying of cable/pipes and getting out in any type of soil, etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.5m above the starting point , complete all as specified and directed.
Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
Brick well burnt locally available sub class "B" laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable all as directed.
M&L for ILIOSBAY PLUS HIGHBAY-IP65 Energy saving, environment friendly & robust IP 65 Protected LED Midbay with PDC housing suitable for ceiling (surface/ suspended) mount and available in wide beam optics 60 watt complete all as specified and directed by Engr-in-Charge. Make : ILIOSBAYPLUSHBP60WLED857SP90DTOPC of Havells or equivalent in Bajaj/ Crompton Greaves/ Philips
S&F JETA Valour integral energy saving, environment friendly, long life, exclusive innovative die-cast aluminium LED flood light 200 Watt with highly efficient leds as light source, suitable for highlighting architectual features, Make : CAT 757PINTNBLTG of Havells OR Equivalent of Philips, Complete AS Specified and directed.
S&F LYCUS environment firendly, new generation, energy saving, decorative SPIKE LIGHT using COB LED as light source 9 WATT complete all as specified and directed by Engr-in-Charge. Make : CAT No LYCUSSPS9WLED730PSYMBOTG of Havells or Equivalent of Philips/Bajaj/Wipro/C&S.
Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M/S SHIMAR STAR GLACIER
JK BUILDERS AND ENGINEERS
NAJAR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .