Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹28.1 L+₹3.5 L (14.0%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹28.3 L+₹3.6 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹29.3 L+₹4.6 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Rejected being not lowest bidder | |
| 5 | L5₹29.8 L+₹5.1 L (20.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
20 Apr 2021, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPECIAL REPAIR TO BLDG NO P 60 P 62 AND THEIR PAVED AREA AT ARSENAL OF CAFVD KIRKEE UNDER GE(C) KIRKEE
2021_MES_433047_1
CWE/KKE/TOKEN-73 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹66,000
Yes
Headquarters CWE Kirkee, Military Engineer Service
21 Jun 2021
25 Mar 2021
22 Apr 2021
25 Mar 2021
20 Apr 2021
15 Apr 2021
26 Mar 2021 - 12 Apr 2021
12 Apr 2021
Amount
Taking down chowkats and frame exc 1.5 Sqm and n.exc 4 .00 sqm each including shutters without taking off shutters from the frame and removing from site. complete all as specified and directed
S&F for Pressed steel frames size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
Supply and fix 35mm thick plain, framed paneled factory made shutters (two panels) door with lock rail and panel of 12mm thick veneered wood board with commercial veneering on both faces and with second class hard wood rails and styles. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated. complete all as specified and as directed.
M&L for 35 mm thick 2nd class hard wood glazed/gaused and skelton window/ventilator shutter, factory made, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 8.24(a) and fixed to chowkat, complete all as specified and as directed.
S&F Steel rolling shutters, Thickness of laths in 1.25mm with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
S & F Galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and as directed.
S&F in repair Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples Size of mesh 12 mm complete all as specified and as directed.
S & F 200mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S & F Aluminium handles, cast type, anodised of size 150mm, fixed with screws or welded complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified and directed.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete as specified and directed.
S&F anodised aluminium snap grid frame work 605 x 605mm for false ceiling complete all as specified and as directed
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removal of debris out side MD land complete all as specified and as directed.
M & L rendering 20 mm thick in two layer on stone masonry surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed.
Dismantling Single layer Mangalore pattern or similar tiles or ridge in roofing complete all as specified and as directed.
S&F roof tiles , Mangalore Pattern, inter locking at side joints laid dry complete all as specified and as directed.
Fixing only roof tiles , Mangalore Pattern, inter locking at side joints laid dry complete all as specified and as directed.
S&F ridge or hip tiles to suit Mangalore Pattern of roofing tiles bedded and jointed in CM 1:6 complete all as specified and as directed.
S & F second class hard wood clean sawn battens at 30 cm centre to centre and sectional area exceeding 15 and not exceeding 25 Sqcm including dismantling Battens for tiles ,singles etc of any size including tiling fillets spaced exc.15 cm complete all as specified and as directed.
S & F 2nd class H/W plain fillets, rails, rafters, purlins, square, rectangular in section clean sawn secured with nails brads exc 13 sqcm but n exc 25 sqcm including dismantling timber scantlings in fillets, rails, posts, rafters, purlins etc under 40 sq. cm in section (Unframed work) in any position complete all as specified and as directed.
M&L for Preparing surfaces of wood and wood based materials new or old of any description and girth, not other wise described and treated with two coat of creosote oil complete all as specified and as directed.
S & F for 0.63 Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 120gms/Sqm including dismantling of plain or corrugated steel sheeting any gauge thickness Dismantling of plain or corrugated sheeting any gauge thickness including Nainital or similar pattern as in roof covering complete all as specified and directed.
S & F for plain, galvanised mild steel sheeting in ridges hips valley gutters drip and straight flashing (length and girth as fixed) by using 1.00mm thick sheet grade of zinc coating @120 Gms/Sqm both sides and welded or soldered joints are provided including dismantling of plain or corrugated steel sheeting any gauge thickness including Nainital or similar pattern as in roof covering/valley gutters complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in cement mortar (1:4) complete all as specified and as directed.
Removing cement mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including all extra handling and removal and disposing off rubbish complete all as specified and as directed.
All as per item No 28 above but except stone complete all as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified of random rubble walling, coursed, hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 40mm on lime/sand stone all as specified and directed.
M&L for Raised pointing to RR masonry in CM 1:4 complete all as specified and as directed.
Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in lime or mud mortar; not previously plastered; and scrubbing down with water etc. to receive plaster or pointing complete all as specified and as directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premisess complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving below or above GL.complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 Type C2 using 40 mm graded stone aggregate as in sub base of floor, mass concrete finished even and fair complete all as specified and as directed.
M&L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing,over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for rendering 10mm thick plaster in cm (1:4) on fair faces of brick work or concrete surfaces including finishing the surface fair and even complete all as specified and as directed.
M&L for machine cut kota stone 18 to 20mm thick as in skirting /Dado, in riser of steps, and pillarset and jointed in neat cement slurry and pointed in coloured cement to match the shade of kota stone slab including, rubbing and polishing laid over and including 10mm thick backing coat in cement mortar (1:4). complete all as specified and as directed.
M & L for 25 mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in floor, pavings or levelling course for floor tiles, etc, finishing the surface fair and even without using extra cement. complete all as specified and as directed.
M&L Non - skid coloured Ceramic tiles 600x600x7 to 8 mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match (light colour), laid over and including 10mm thick backing coat in cement mortar (1:4) including triangular filleting on top in cement mortar (1:4) complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded agg) as in plinth protection incl finishing even & smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered surfaces of wall incl preparation of surfacesand applying a thin coat of wall care putty, two coat oil bound distemper over one coat of water based interior wall primer complete all as specified and directed.
M&L for Preparation of old surfaces (Plastered or un-plastered) of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of one coat of pink primer complete all as specified and directed.
M&L for preparation old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of new or old steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 Type D2 using 40 mm graded stone aggregate as in sub base of floor, mass concrete finished even and fair complete all as specified and directed.
M&L for precast cement concrete interlocking tiles, paver block, any shape and size as approved , 80mm thick, conforming to IS 15658-2006, M-40 grade in floor/pavement, laid over and including 30mm thick sand cushioning, laid dry to the profile including vibrating with surface vibrator after laying of tiles all as specified and directed.
M&L for PCC 1:2:4 type B1 ( Using 20mm graded agg) as in plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates concrete complete all as specified and directed.
Material and labour for coloured chequered cement concrete tiles of size 30 cm x 30 cm x25 mm thick with grey cement and pigments, set jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed or bedding layer of cement mortar in CM (1:6), complete all as specified and directed.
Taking down carefully existing unserviceable aluminum / copper point wiring of any description & in any position with and including existing steel conduit / PVC Conduit / Casing caping fixed on surface/wall/angle/gardder and including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, sockets, etc including sunken boxes/junction boxes and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
M&L for point wiring consealed type in non metallic PVCconduit of suitable size not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles etc. with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl suncun type MS sheet box of 1.6 mm thick of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall inclooding repairing material all as specified and directed by Engineer in charge. NOTE :- Cutting /chasing to consealed the conduit pipe and fixing of sunkun box is to be done in brick / solid concrete block mashnary wall upto ceiling height and then on ceiling .
All as per Srl item No 55 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 55 above but point wiring for 5 pin ocket outlet 5 Amps on independent board.
All as per Srl item No 55 above but point wiring for one five pin switch socket outlet combination, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
Supplying & fixing switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed
Supplying & fixing socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified & directed
Supplying & fixing switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed
Supplying & fixing Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , flush type, 230 volts AC circuit complete all as specified & directed
Supplying & fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified & directed .
Supply and fixing Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall all as specified and directed by Engineer in charge.
Material and labour for Sub main wiring at any height consealed type with and including two single core PVC insulated multi stranded copper conductor cable, ISI marked, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC non metallic conduit including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, ISI marked, FRLSH type, 4.0 sqmm, 1100 Volts grade, ISI marked, as earth contuinity wire all as specified and directed by Engineer in charge. (Note:- (i) Two runs of cables & continuous earth wire in new PVC casing and caping / PVC non metallic conduit will be measured as one length of sub main wiring).
S&F Ceiling fan 230 volt single phase 50 hz 1200mm sweep with complete down rod canopy hanging hook and flexible cable two core from ceiling fan to connection all as specified and directed make Havells modal ES-40 or equivalent. As approved by GE.
Supplying, fixing, connecting up to existing/new ceiling rose and testing surface mounting LED Tube Light Batten Fitting 1x20 Watt 4 feet white colour tube lamp including connecting with 23/0.0076 copper conductor flexible twisted three core cable including all accessories (mounting SS clips) and fixing arrangements for fixing the light fitting on wallcomplete all as specified & directed including dismantling of old fittings. Make Havells/C&S/Philips as approved by GE.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 36 W aesthetically designed 2x2 LED recess mounting in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted three core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed. Make Bajaj/CG/Philips/Havells/C&S as approved by GE.
Disconnecting and taking down old switch fuse type distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
Supply, fixing, connecting & testing double door sheet metal SPN distribution board 8 way with 100 Amps rated copper bus bar, IP 54, IK 09 class, inclusive of Neutral bar, Earthbar and Cable ties for Cable management complete all as specified & directed. Make - Legrand/L&T/ ABB/Schenider as approved by GE.
Supply, fixing, connecting & testing double door sheet metal SPN distribution board 12 way with 100 Amps rated copper bus bar, IP 54, IK 09 class, inclusive of Neutral bar, Earthbar and Cable ties for Cable management complete all as specified & directed. Make - Legrand/L&T/ ABB/Schenider as approved by GE.
Supplying & fixing in replacement MCB 6 to 32 Amps, single pole and neutral, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters complete all as specified and directed. Make - Legrand/ABB/L&T/ Seimens as approved by GE.
Supplying & fixing in replacement MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters complete all as specified and directed. Make - Legrand/ABB/L&T/ Seimens as approved by GE.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground, earth pit not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5mtr below GL connected to and including 25 x 4 mm GI strip upto 7.5 m long by means of GI bolts, nuts, check nuts & washers and connected to earthing test point & earth dolly all as shown in electrical plate No 3 of SSR part I- (2009), earth lead protected with and including 40 mm bore GI pipe light grade and 20 mm bore medium grade watering pipe and testing on completion including excavation & earth work in any type of strata , PCC (1:3:6) type C-I chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric of XPM, weight not less than 4 Kg /Sqm) with cast iron frame ,funnel with water pipe , wire mesh and lugs etc complete all as specified and directed by engr-in-charge.
S&F earth continuity conductor or main earthing lead of size 4 mm dia G I Wire fixed to wall drawn in conduit/pipe or any other indicated situation for loop earthing etc. incl removal of old as required all as specified and directed
Disconnecting and taking out burnt Service Wire aluminium conductor cable of any description and in any position from walls / steel structure / laid in floors any size any core complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches in any type of soil not exceeding 1.5 Metre deep and not exceeding 1.5 metre width n exc 10 sqm on plan and getting out including forming bottom surface & sides to required slope/size as directed by the Engineer-in-Charge
Removal of surplus excavated soil not exceeding 50 Mtr distance and depositing where directed by the Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed by Engineer-in-Charge.
Material & labour for pulvarised stone dust filling with including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. (Note: Thickness after punning down shall be measured and paid)
Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
Supply and laying in trenches / laid in floor/duct /drawn through conduit XLPE insulated PVC bedded armored heavy duty electric cable 1100 Volt grade with aluminum conductor of cross sectional are 4 x 16 Sq mm all as specified and direcred .
Supply & fixing, light grade, 40 mm dia GI tubing with all fittings fixed on walls/ poles/ in trenches as in earth lead or protection pipe for cables all as specified & directed .
M/S JAYCONSTRUCTION CO
GGS Infra
Shri Sant Cosntruction
ganesh electricals and airconditioners
V.R.PRAJAPATI AND CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .