| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-Finance 2 206 C PONNAGAR METTUR DAM 636 401 SALEM DISTRICT | SALEM | TAMIL NADU | 636401 | ₹3.3 L | L1 | Accepted-Finance L1 |
| 2 | L2₹3.7 L+₹42,594 (12.8%)Accepted-Finance 39 288 THANGAMAPURIPATNAM METTUR DAM 2 METTUR DAM 636 406 | METTUR DAM | SALEM | TAMIL NADU | 636406 | ₹3.7 L+₹42,594 (12.8%) | L2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | mettursrikrishna enterprises L2 | SARVESWARASAMY AND CO L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for removal of local pressure gauges/ temperature gauges and refixing them after calibration in Boiler, Turbine & Generator areas. | 50 | Nos | 470 ₹23,500 | 417 ₹20,850 Lowest |
| 2.00 | Charges for removal of pressure/Temperature/ Vacuum/flow switches and refixing them after calibration in Boiler, Turbine and Generator areas. | 25 | Nos | 470 ₹11,750 | 417 ₹10,425 Lowest |
| 3.00 | Charges for removal of Pressure /Temperature transmitter including disconnecting the control cables, removal of clamps & manifold and refixing them after calibration in Boiler, Turbine & Generator areas. | 30 | Nos | 470 ₹14,100 | 417 ₹12,510 Lowest |
| 4.00 | Charges for dismantling, cleaning, replacement of gaskets (280x280mm) and re-fitting of level switch. | 32 | Nos | 2,348 ₹75,136 | 2,076 ₹66,432 Lowest |
| 5.00 | Charges for removing and refitting of accessories in pneumatic control valves & dampers such as I/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing, and receiving the tested instruments from lab . | 55 | Nos | 1,960 ₹1,07,800 | 1,733 ₹95,315 Lowest |
| 6.00 | Charges for Replacement of HAD/CAD cylinder (8" Bore and 8" stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting and unloading of new pneumatic cylinder from central store to field location.iii) Fixing the new pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubing. | 2 | Nos | 6,000 ₹12,000 | 5,309 ₹10,618 Lowest |
| 7.00 | Charges for rectification and welding of broken doors in junction boxes. | 10 | Nos | 625 ₹6,250 | 553 ₹5,530 Lowest |
| 8.00 | Charges for opening and cleaning of ½” impulse lines and catch pots in mills, Flue gas, primary and secondary air paths. | 110 | Nos | 420 ₹46,200 | 384 ₹42,240 Lowest |
| 9.00 | Charges for cutting and welding of takeoff catch pots in mills, flue gas and primary and secondary air path. | 10 | Nos | 656 ₹6,560 | 581 ₹5,810 Lowest |
| 10.00 | Charges for single point cutting and welding of pipe size ½” impulse lines of mills, flue gas, primary and secondary air path. | 10 | Nos | 512 ₹5,120 | 452 ₹4,520 Lowest |
Tender Value
Refer Docs
EMD Value
₹3,100
Closing Date
15 Sept 2026, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER/MTPS-I
MTPSI ES Circle CI UnitII Removal and refixing of pressure gauges Temperature gauges switches Transmitters after calibration Replacement of gaskets for level switches cleaning of impulse lines and catch pots etc. during Annual overhaul 2026.
2026_EB_699425_1
CE-MTPSI-SE-ES-CI-OT13-26-27
Open Tender
Electrical Works
Works
20 days
MTPS-I/METTURDAM
As per tender specification
4 documents required · 4 mandatory
₹0
₹3,100
Yes
22 Sept 2026
29 Aug 2026
16 Sept 2026
29 Aug 2026
15 Sept 2026
29 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for removal of local pressure gauges/ temperature gauges and refixing them after calibration in Boiler, Turbine & Generator areas. | 50 | Nos | - | - |
| 2 | Charges for removal of pressure/Temperature/ Vacuum/flow switches and refixing them after calibration in Boiler, Turbine and Generator areas. | 25 | Nos | - | - |
| 3 | Charges for removal of Pressure /Temperature transmitter including disconnecting the control cables, removal of clamps & manifold and refixing them after calibration in Boiler, Turbine & Generator areas. | 30 | Nos | - | - |
| 4 | Charges for dismantling, cleaning, replacement of gaskets (280x280mm) and re-fitting of level switch. | 32 | Nos | - | - |
| 5 | Charges for removing and refitting of accessories in pneumatic control valves & dampers such as I/P converters, air lock relay, air regulators, positioners and position feedback transmitters sending to lab for testing, and receiving the tested instruments from lab . | 55 | Nos | - | - |
| 6 | Charges for Replacement of HAD/CAD cylinder (8" Bore and 8" stroke) which involves following works.i) Removal of existing pneumatic cylinder and its accessories with copper tubings from its location to pocket store.ii) Loading, transporting and unloading of new pneumatic cylinder from central store to field location.iii) Fixing the new pneumatic cylinder and refixing the accessories such as air regulator, I/P converter with SS tubing. | 2 | Nos | - | - |
| 7 | Charges for rectification and welding of broken doors in junction boxes. | 10 | Nos | - | - |
| 8 | Charges for opening and cleaning of ½” impulse lines and catch pots in mills, Flue gas, primary and secondary air paths. | 110 | Nos | - | - |
| 9 | Charges for cutting and welding of takeoff catch pots in mills, flue gas and primary and secondary air path. | 10 | Nos | - | - |
| 10 | Charges for single point cutting and welding of pipe size ½” impulse lines of mills, flue gas, primary and secondary air path. | 10 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_840814.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .