Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.0 LAccepted-AOC 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | 1 | Accepted-AOC Accepted being L1 | |
| 2 | 2₹24.0 L+₹4.0 L (20.2%)Rejected-Finance | 2 | Rejected-Finance Rejected being Not L1 | |
| 3 | 3₹24.6 L+₹4.6 L (23.0%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 3 | Rejected-Finance Rejected being Not L1 | |
| 4 | 4₹28.2 L+₹8.2 L (40.8%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 4 | Rejected-Finance Rejected being Not L1 | |
| 5 | 5₹30.5 L+₹10.5 L (52.4%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | 5 | Rejected-Finance Rejected being Not L1 |
| Sl No | Description | Qty | Unit | Rajindera Enterprises L6 | MV Engineers And Contractors L3 | mayur enterprises L4 | Microsys Automation India L2 | SB ENTERPRISES L1 | M P TYAGI ENGINEERS AND CONTRACTORS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and laying in replacement of RS 485 scada communication cable size 2 core 1.5 Sqmm complete all as specified and directed by Engr-in-Charge. | 200 | RM | 100 ₹20,000 | 65 ₹13,000 | 250 ₹50,000 | 60 ₹12,000 | 59 ₹11,800 Lowest | 100 ₹20,000 |
| 2.00 | Supply and fixing of ring type aluminium lugs of size 25 sqmm complete all as specified and directed by Engr-in-Charge. | 100 | Each | 100 ₹10,000 | 60 ₹6,000 | 15 ₹1,500 | 6 ₹600 Lowest | 19 ₹1,900 | 100 ₹10,000 |
| 3.00 | Supply and fixing of pin type copper lugs of size 25 sqmm complete all as specified and directed by Engr-in-Charge. | 100 | Each | 200 ₹20,000 | 150 ₹15,000 | 45 ₹4,500 | 20 ₹2,000 Lowest | 49 ₹4,900 | 100 ₹10,000 |
| 4.00 | Supply and fixing in replacement of GI Flexible pipe size 25 to 32 mm for DC cabling and AC Cabling system complete all as specified and directed by Engr-in-Charge. | 2,000 | RM | 60 ₹1,20,000 | 45 ₹90,000 | 70 ₹1,40,000 | 12 ₹24,000 Lowest | 49 ₹98,000 | 100 ₹2,00,000 |
| 5.00 | Supply and fixing of Pre-galvanised C channel of size (50x40x10x2mm) for roof top solar panel complete all as specified and directed by Engr-in-Charge. | 120 | RM | 200 ₹24,000 | 400 ₹48,000 | 600 ₹72,000 | 120 ₹14,400 | 609 ₹73,080 | 100 ₹12,000 Lowest |
| 6.00 | Material and labour for PCC 1:2:4 type B1 for foundation size 300 mm x 300mm x 300 mm complete all as specified and directed by Engr-in-Charge. | 25 | Each Job | 1,000 ₹25,000 | 200 ₹5,000 | 300 ₹7,500 | 2,000 ₹50,000 | 299 ₹7,475 | 100 ₹2,500 Lowest |
| 7.00 | Supply and fixing in replacement of GI 'J' Bolts size M12 x 200 mm suitable for solar panel complete all as specified and directed by Engr-in-Charge.
Make : GI | 250 | Each | 100 ₹25,000 | 25 ₹6,250 | 30 ₹7,500 | 22 ₹5,500 Lowest | 39 ₹9,750 | 100 ₹25,000 |
| 8.00 | Supply and fixing in replacement of MC4 connector (EMPV4) for connection of module in series and Parellel suitable for solar panel complete all as specified and directed by Engr-in-Charge. Make : Elemax | 150 | Each | 50 ₹7,500 | 45 ₹6,750 Lowest | 70 ₹10,500 | 120 ₹18,000 | 69 ₹10,350 | 100 ₹15,000 |
| 9.00 | Supply and laying in replacement of DC Cable size 1 core 4 Sqmm Black colour complete all as specified and directed by Engr-in-Charge. | 1,000 | RM | 50 ₹50,000 | 60 ₹60,000 | 75 ₹75,000 | 80 ₹80,000 | 49 ₹49,000 | 10 ₹10,000 Lowest |
| 10.00 | Material and labour in replacement of all accessories like cable tie, sealant foam & electrical tape as per site requirement, ABC type fire extinguisher 2 Kg complete all as specified and directed by Engr-in-Charge. | 4 | Each Set | 20,000 ₹80,000 | 13,500 ₹54,000 | 5,000 ₹20,000 | 2,000 ₹8,000 Lowest | 11,999 ₹47,996 | 5,000 ₹20,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Jun 2025, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR MAINTENANCE CLEANING AND SERVICING OF SOLAR POWER PLANT AT NOMA KOTA HOUSE 100 KWP E IN C BRANCH 100 KWP HQ DGBR 220 KWP GE U OFFICE COMPLEX 20 KWP DELHI AREA CAMP 30 KWP HQ DELHI AREA 50KWP PARADE GROUND BARRACKS 50KWP A
2025_MES_709845_1
GE ELECT/D-21/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹60,000
Yes
22 Aug 2025
23 May 2025
3 Jul 2025
23 May 2025
30 Jun 2025
16 Jun 2025
Amount
Supply and laying in replacement of RS 485 scada communication cable size 2 core 1.5 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of ring type aluminium lugs of size 25 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of pin type copper lugs of size 25 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of GI Flexible pipe size 25 to 32 mm for DC cabling and AC Cabling system complete all as specified and directed by Engr-in-Charge.
Supply and fixing of Pre-galvanised C channel of size (50x40x10x2mm) for roof top solar panel complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:2:4 type B1 for foundation size 300 mm x 300mm x 300 mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of GI 'J' Bolts size M12 x 200 mm suitable for solar panel complete all as specified and directed by Engr-in-Charge. Make : GI
Supply and fixing in replacement of MC4 connector (EMPV4) for connection of module in series and Parellel suitable for solar panel complete all as specified and directed by Engr-in-Charge. Make : Elemax
Supply and laying in replacement of DC Cable size 1 core 4 Sqmm Black colour complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of all accessories like cable tie, sealant foam & electrical tape as per site requirement, ABC type fire extinguisher 2 Kg complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of HDPE conduit pipe size 40 mm x 32 mm for DC cabling and AC Cabling system complete all as specified and directed by Engr-in-Charge.
Note for Item No 1 to 11 :- (a) The approximate quantiies of solar module required in place of defective unserviceable solar module mentioned above however if there is any physical damage to solar module till completion of work must be change by the bidder of same specification and the cost of the same should be included in the quoted rate. (b) Existing Three phase On-Grid inverter must be used however if there is any physical damage inverter must be change by the bidder of same specification and the cost of the same should be included in the quoted rate. (c) Balance of system (BOS) items/components: The BOS items/components of the SPV power plants/systems deployed under this project must conform to the latest edition of IEC or equivalent BIS Standards /MNRE specifications. (d) Mounting structure :- (i) Mild steel structure, Hot Dip Galvanised of 80 micron thick, corrosion resistant and electrolytically compatible with material used in modular frame mounting Structure Shall be used. Galvanization shall conform to IS-2629, 4759 & 4736 as applicable. (ii) On Galvalume Sheet Roof, The fasteners shall be of stainless steel to fix the module mounting strucuture to the continous Rails. The continous Rails shall be mounted to Purlins only using L cleats in order to avoid any load on Galvalume Sheet. L cleats shall be mounted using SDS Screws of Minimum 68 mm height. EPDM tape shall be used to provide water leakage protection. Module mounting structure shall require to be customize with respect to the site availability.Test certificate of galvanization shall be submitted by contractor. (e) All fasteners shall be of Stainless steel-SS 304 Nut & bolts, supporting structures including module Mounting Structures shall have to be adequately protected against all climatic condition. (f) Any damage done to water proofing/roof structure/ Galvalume Sheet during installation shall be made good by the contractor at no extra cost. (g) Lightening protection - Existing lightening protection to be used. However lightening protection if required must be replaced as specified above and the cost of the same deemed to be included in quoted rate.
Note for Item No 1 to 11 (Cont'd) :- (h) Earthing Protection - Existing lightening protection to be used. However lightening protection if required must be replaced as specified above and the cost of the same shall be deemed to be included in quoted rate. (j) Metering arrangements: Plants to be connected with existing net meter
Supply and fixing of Pre-galvanised cable tray of size 50 mm x 25mm x 2 mm thick complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of stainless steel Nut Bolts with washers size M6 of SS 304 complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Pre-Galvanised Purlin (Strut channel) size 40mm x 40mm x 2mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Poly Silicon Crystalline Terrestrial PV module IEC-61215/IS--14286/Equivalent IS of Solar Photo Voltaic module 300 Wp complete all as specified and directed by Engr-in-Charge. Make : Vikram Solar/Indo Solar/Tata Solar/Adani. Notes : (a) PV modules shall be used in the Solar power plants /sytems will be designed for their output peak watt capacity which should not be less than 90% at the end of 10 years and 80% at the end of 25 Years. (b) Contractor shall submit the warranty certificate from the manufacturer and will submit the same to the concerned GE Office. (e) PV modules must qualify (enclose test reports/certificate from IEC/NABL accredited laboratory) as per relevant IEC standard.
Taking down carefully and sending to workshop for repair of 20 KW on Grid Inverter complete all as specified and directed by Engr-in-Charge. Make : Delta
Taking down carefully and sending to workshop for repair of 30 KW On Grid Inverter complete all as specified and directed by Engr-in-Charge. Make : Delta
Taking down carefully and sending to workshop for repair of 50 KW On Grid Inverter complete all as specified and directed by Engr-in-Charge. Make : Delta
Taking down carefully and sending to workshop for repair of 70 KW On Grid Inverter complete all as specified and directed by Engr-in-Charge. Make : Delta
Supply and fixing in replacement of DC distribution board suitable for existing 50 KW Solar Plant complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of AC distribution board suitable for existing 50 KW Solar Plant complete all as specified and directed by Engr-in-Charge.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be, for 100 KW Solar Power plant at E-in-C Branch, Kashmir House New Delhi complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be for 100 KW Solar Plant at Noma Kota House New Delhi complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be for 250 KW Solar Plant at Harbaksh Stadium complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be for 50 KW Solar Plant at HQ Delhi Area complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be for 50 KW Parade Camp Area complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be for 30 KW Delhi Area Camp complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Operation and Comprehensive Maintenance including making good of all kind of defects by repair/replacement of required spare parts as the case may be for 20 kw GE (U) E/S Office complex bldg complete all as specified and directed by Engr-in-Charge. Note :- (a) Operation and maintenance shall include washing / cleaning of Solar PV Modules on monthly basis . (b) Checking Electrical Parameter of the installed power plant. (c) The defective items shall be replaced by the contractor and shall be measured under respective items of this schedule.
Monthly Data Service and Maintenance: On the first day of each calendar month, the contractor shall ensure the active data service (herein referred to as "recharge") for all solar SIM cards associated with each operational unit (herein referred to as "rotors") of the following :- (a) HQ DGBR 220 kwP = 02 Nos Sim (b) GE (U) OFFICE COMPLEX20 kwp = 01 Nos Sim (c) DELHI AREA CAMP 30 kwp = 01 Nos Sim (d) HQ DELHI AREA 50Kwp = 01 Nos sim (e) PARADE GROUND BARRACKS 50 kwp = 01 Nos Sim (f) HARBAKSH STADIUM 250 Kwp = 01 Nos sim (g) E-in-C Branch (100 kwp) = 01 Nos sim Furthermore, the contractor shall be responsible for maintaining and updating all data received from these rotors as necessary for the proper functioning of the system, as outlined in Schedule [Reference relevant schedule for data maintenance details.
Material and labour for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engr-in-Charge.
Material and labour for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Material and labour for removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engr-in-Charge.
Supply & fixing of sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engr-in-Charge.
All as per srl item No 34 here-in-before but using old bricks obtained under srl item No 30 here in before complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing, testing and connecting in replacement of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by Engr-in-Charge of following sizes:- Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
95 Sqmm 3.5 core
120 Sqmm 3.5 core
Material and labour for boring of hole under road/pavement/hard standing or any other situation by manual means upto depth of 0.90 mtr below ground level and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections /pole for crossing of culverts/nallah complete all as specified and directed by Engr-in-Charge of following bore sizes:-
Material and labour in replacement of Earthing with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified, including testing and commissioning complete all as specified and directed by Engr-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply, laying, testing and commisioning of LT underground cable PVC insulated armoured heavy duty 1100 Volts grade confirming to IS 7098 Part-1 1988 with copper conductor multistranded including centre gland lungs jointing materials etc laid in trench or fixed it to wall or passing through pipes includung taking out old un-serviceable LT Cable complete all as specified and directed by Engr-in-Charge for the following sizes :- Note:-Excavation of earth work PCC covers and cushions will be measured and paid separately
Cross sectional area 2.5 Sqmm, 3core
Cross sectional area 4 Sqmm, 3core
Cross sectional area 6 Sqmm, 3core
Supply & fixing in replacement PVC insulated flexible copper conductor cable, multistrand 1100 volt grade, PVC sheathed of nominal area 4.00 Sqmm single core complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement PVC insulated flexible copper conductor cable, multistrand 1100 volt grade, PVC sheathed of nominal area 6.00 Sqmm single core complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement GSM based and Play RTU with smart data logger to connect inverters complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement IP-65 enclosure box with SMPS power supply and other accessories to house the RTU complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement MCB single pole 6 to 32 Amp with rupturing capacity 10KA, 'C' complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement MCB SPN complete 63 Amp with rupturing capacity 10 KA 'C' series complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement MCCB 100 Amp, 4 pole , 25 KA, 50 Hz including MCCB with sheet metal enclosure mounted on wall with fastner and suitable size of nut and bolts complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement MCCB 160 Amp, 4 pole , 25 KA, 50 Hz including MCCB with sheet metal enclosure mounted on wall with fastner and suitable size of nut and bolts complete all as specified and directed by Engr-in-Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge.
Microsys Automation India (BID ID -3341230)
MV Engineers And Contractors (BID ID -3332142)
mayur enterprises (BID ID -3333144)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3333991)
Rajindera Enterprises (BID ID -3328609)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .