Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹42.6 L+₹1.3 L (3.12%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹42.7 L+₹1.3 L (3.21%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹44.2 L+₹2.9 L (7.00%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹44.7 L+₹3.3 L (8.09%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
| Sl No | Description | Qty | Unit | M/S JAYCONSTRUCTION CO L3 | M/S J J ENTERPRISES L1 | BHABA CONSTRUCTION L2 | M/S SANDEEP CONSTRUCTION COMPANY L4 | BHARDWAJ ENTERPRISES L7 | SAMBHAJI D JARANDE L5 | ShreHari Civil Enginneering and Contractors L8 | S V CONSTRUCTION L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc of any description complete all as specified and directed | 130 | Sqm | 20 ₹2,600 Lowest | 75 ₹9,750 | 55 ₹7,150 | 80 ₹10,400 | 20 ₹2,600 Lowest | 20 ₹2,600 Lowest | 100 ₹13,000 | 20 ₹2,600 Lowest |
| 2.00 | Material & Labour for rendering on wall 15 mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 mixed with water liquid proofing compound all as per manufacturers instructions and finished even and smooth without using extra cement complete all as specified and directed
Note : WPC shall be measured & paid seprately | 35 | Sqm | 250 ₹8,750 | 270 ₹9,450 | 270 ₹9,450 | 250 ₹8,750 | 200 ₹7,000 Lowest | 300 ₹10,500 | 325 ₹11,375 | 250 ₹8,750 |
| 3.00 | Material & Labour for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM 1:3 mixing with liquid water proofing compound all as per manufactureres instructions, finished even and smooth without using extra cement complete all as specified and directed
Note :- WPC shall be measured & paid seprately. | 35 | Sqm | 500 ₹17,500 | 275 ₹9,625 | 265 ₹9,275 | 2,200 ₹77,000 | 190 ₹6,650 Lowest | 300 ₹10,500 | 325 ₹11,375 | 240 ₹8,400 |
| 4.00 | Supply only liquid water proofing compound complete all as specified and directed | 5 | Ltr | 100 ₹500 | 125 ₹625 | 90 ₹450 Lowest | 500 ₹2,500 | 220 ₹1,100 | 100 ₹500 | 250 ₹1,250 | 100 ₹500 |
| 5.00 | Material & Labour for preperation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint (apex Ultima or equivalent) with approved colour and pattern over and including a coat of primer as on walls of Bldgs of upto 12 mtr height including necessary scaffolding and safety measures and procedure complete all as specified and directed.
Note : Safety precaution sscaffolding and safety measures like rope, safety belts, helmets, ladder etc shall be responsibility of contractor | 70 | Sqm | 150 ₹10,500 Lowest | 180 ₹12,600 | 170 ₹11,900 | 250 ₹17,500 | 150 ₹10,500 Lowest | 200 ₹14,000 | 200 ₹14,000 | 200 ₹14,000 |
| 6.00 | Material & Labour for complete removal of existing treatment for preparation of old decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint(Asian Apex Ultima or Equivalent) of approved tint over and including a coat of weather proof primer (Asian True care exterior wall primer or Equivalent) with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturer's instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6 to 8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed.
NOTE :- Rate quoted shall be deemed to be inclusive for scaffolding up to 30 mtr height building. | 950 | Sqm | 200 ₹1,90,000 Lowest | 325 ₹3,08,750 | 360 ₹3,42,000 | 220 ₹2,09,000 | 1,000 ₹9,50,000 | 200 ₹1,90,000 Lowest | 250 ₹2,37,500 | 250 ₹2,37,500 |
| 7.00 | Material & Labour for 10 mm thick plastering on fair faces of brickwork,or concrete surface in CM 1:6 with finishing the surface even and smooth(without using extra cement) complete all as specified and directed by Engineer in charge | 40 | Sqm | 250 ₹10,000 | 235 ₹9,400 | 195 ₹7,800 | 300 ₹12,000 | 180 ₹7,200 Lowest | 290 ₹11,600 | 250 ₹10,000 | 230 ₹9,200 |
| 8.00 | Material & Labour for rendering 10 mm thick in cement mortar 1:4 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement complete all as specified and directed | 20 | Sqm | 250 ₹5,000 | 245 ₹4,900 | 210 ₹4,200 | 300 ₹6,000 | 150 ₹3,000 Lowest | 300 ₹6,000 | 250 ₹5,000 | 150 ₹3,000 Lowest |
| 9.00 | Material & Labour for applying three coats of white wash to newly plastered surface including preparation complete all as specified and directed | 20 | Sqm | 25 ₹500 | 22 ₹440 | 25 ₹500 | 50 ₹1,000 | 20 ₹400 Lowest | 40 ₹800 | 40 ₹800 | 20 ₹400 Lowest |
| 10.00 | Material & Labour for complete removal of existing internal finishes for preparation of old decorated treatment on wall by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Plastic Emulsion Paint (Asian Tractor Emulsion or equivalent) over and including one coat of acrylic wall care putty of 1 mm thickness over and including one coat of trucare internal wall primer complete all as specified and directed. | 200 | Sqm | 100 ₹20,000 Lowest | 235 ₹47,000 | 240 ₹48,000 | 200 ₹40,000 | 400 ₹80,000 | 200 ₹40,000 | 100 ₹20,000 Lowest | 230 ₹46,000 |
Tender Value
Refer Docs
EMD Value
₹95,040
Closing Date
8 Aug 2025, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
SPECIAL REPAIR TO BLDG NO P 10 AND P 4 OF MH KHADKI UNDER GE MH AND RH KHADKI
2025_MES_721378_1
8713/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹95,040
9 Oct 2025
18 Jul 2025
11 Aug 2025
18 Jul 2025
8 Aug 2025
1 Aug 2025
18 Jul 2025 - 8 Aug 2025
Amount
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc of any description complete all as specified and directed
Material & Labour for rendering on wall 15 mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 mixed with water liquid proofing compound all as per manufacturers instructions and finished even and smooth without using extra cement complete all as specified and directed Note : WPC shall be measured & paid seprately
Material & Labour for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM 1:3 mixing with liquid water proofing compound all as per manufactureres instructions, finished even and smooth without using extra cement complete all as specified and directed Note :- WPC shall be measured & paid seprately.
Supply only liquid water proofing compound complete all as specified and directed
Material & Labour for preperation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint (apex Ultima or equivalent) with approved colour and pattern over and including a coat of primer as on walls of Bldgs of upto 12 mtr height including necessary scaffolding and safety measures and procedure complete all as specified and directed. Note : Safety precaution sscaffolding and safety measures like rope, safety belts, helmets, ladder etc shall be responsibility of contractor
Material & Labour for complete removal of existing treatment for preparation of old decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint(Asian Apex Ultima or Equivalent) of approved tint over and including a coat of weather proof primer (Asian True care exterior wall primer or Equivalent) with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturer's instructions and all coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6 to 8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. NOTE :- Rate quoted shall be deemed to be inclusive for scaffolding up to 30 mtr height building.
Material & Labour for 10 mm thick plastering on fair faces of brickwork,or concrete surface in CM 1:6 with finishing the surface even and smooth(without using extra cement) complete all as specified and directed by Engineer in charge
Material & Labour for rendering 10 mm thick in cement mortar 1:4 on fair faces of concrete surfaces of ceiling finishing even and smooth without using extra cement complete all as specified and directed
Material & Labour for applying three coats of white wash to newly plastered surface including preparation complete all as specified and directed
Material & Labour for complete removal of existing internal finishes for preparation of old decorated treatment on wall by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Plastic Emulsion Paint (Asian Tractor Emulsion or equivalent) over and including one coat of acrylic wall care putty of 1 mm thickness over and including one coat of trucare internal wall primer complete all as specified and directed.
Material & Labour for complete removal of existing internal finishes for preparation of old decorated treatment on wall by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Acrylic washable distember(Asian Tractor UNO or equivalent) over and including one coat of acrylic wall care putty of 1 mm thickness over and including one coat of trucare internal wall primer complete all as specified and directed.
Material & Labour for preparation of new plastered surfaces of wall by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying two coats of Acrylic washable distember(Asian Tractor UNO or equivalent) over and including one coat of acrylic wall care putty of 1 mm thickness over and including one coat of trucare internal wall primer complete all as specified and directed.
Material & Labour for preperation of old surface and applying one coat of dry distemper on ceiling complete all as specified and directed by Engineer in charge
Material & Labour for preparation of old painted surfaces of steel of any description over 10 cm width or girth and applying one coat of synthetic enamel paint(Asian Tractor Enamel or equivalent) complete all as specified and directed.
Material & Labour for preperation of old surface and applying one coat of dry distemper on wall complete all as specified and directed by Engineer in charge
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises complete all as specified and directed.
Demolition of cement concrete unreinforced of any description and in any position, not otherwise specifically provided for as in sunken floors and similar locations complete all as specified and directed
Material & Labour for waterproofing treatment to RCC sunken slab as under:- (a) Cleaning the sunken portion of toilet/Bath/WC/Kitchen throughly to remove laitance, dirt, dust, etc. (b) Material & Labour making hole and fixing 12mm dia PVC Nozzle @0.5 mtr c/c on the entire area of sunken portions and applying chemical injection grouting through the nozzles with cement slurry admixture with dr fixit bath seal grouting or other equivalent with pressure pump in 40 PSI.seal off the nozzleand cutting the same after grout has set complete all as specified and directed by Engineer in charge (c) Form angle fillet or chamfering edges of size 40 mm x 40 mm thick cement sand mortar (1:3) admixed with diluted ("Dr Fixit" Pidicrete URP" or equivalent)1:3 complete all as specified and directed (d) Wet the surfaces with water to make it saturated surface dry condition (e) Sanitary pipes entering through walls and floor shall be sealed with " Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout " Dr Fixit Bathseal Gruot" or eqvt. Nahani traps, etc to be fitted securely and the gaps around it to grouted in the same manner. (f) Ponding test for water leakage will be carried as per IS 3370 complete all as specified and directed (g) Applying 20 mm thick plaster in C:M 1:3 mixed with water proofing compound 3% by weight of Cement as per manufacturer instruction (h) Plumbing works to be providedaccording to proper level&slope seal off the pipesand back fill the gap properly and provide 40mm Outer dia UPVC spout pipe at the lowest point with 300mm projection beyond the outer face of the wall complete all as specified and directed
Material & Labour for the tile joint chemical cleaning and re-grouting carefully by washing the existing tile with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, curing , cleaning the surface etc, complete all as specified and directed by Engineer in charge and as per the sample done at ground level.
Supply & fix Plain 145 gsm fibreglass mesh and apply one coat of Acyrylic polymer modifed cementious slurry coating with "Dr Fixit Bathseal Plus or eqvt " by brush and cover it with 100 mm overlap both ways after necessary preparation of surface when it is still wet complete all as per manufacturers instructions. Apply second coat of the same coating on the angle fillets and allow it to dry completely and turned upto 150mm from FFL at Bath/Wc /Kitchen area's and all as per manufacturer specification complete all as specified and directed
Material & Labour for making hole for fixing nozzles in construction joints/whereas required and patching the joint with cement sand mortar and grouting the PVC nozzles thus fixed with cement slurry admixed with Non shrink polymeric grouting compound(Make Pidilite or equivalent ) and clean the RCC Subdtrate of all oil,grease and loosely adhering particles and repairs the cracks with CM 1:3 and Dr Fixit Pidicrete URP complete all as specified and directed
Material & Labour for PCC (1:5:10) using 40mm graded stone aggregate as in mass concrete or as in sunken floor complete all as specified & directed
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified & directed
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified & directed
Supply & fix steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall complete all as specified and directed by Engineer-in-charge.
Supply & fix steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall complete all as specified and directed by Engineer-in-charge.
Re Fixing old steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall complete all as specified and directed by Engineer-in-charge.
Re Fixing old steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall complete all as specified and directed by Engineer-in-charge.
Material & Labour for Vitrified ceramic tiles(matt finishes) 10mm thickcolour/ Dark shade (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed
Material & Labour for Coloured ceramic tiles in vertical surface 300 x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile laid over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed
Material & Labour for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles complete all as specified and directed
Supply & fix in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe, anti syphonage pipe etc complete and making good to floor complete all as specified and directed
Supply & fix CP wall mixer 3 in 1 system with provision for both hand shower and overhead showercomplete with 115mm long bend pipe connecting legs &wall flange screwed down for iron pipe complete all as specified and directed. Make : Johnson or other techno commercial equivalent
Material & Labour for providing and fixing stainlesssteel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and taking curvature (where everrequired) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel boltsetc., of required size, on the top of floor orthe side of waist slab with suitable arrangement including holes drilled any dia and depth as required complete all as specified and directed
Supply only PVC low level flushing system 10 Ltr capacity with flush pipe complete as specified and directed in repairs.
Supply only PVC seat and cover for pedastal pattern complete all as specified and directed
Supply & fix in repairs stop valves cast copper alloy CP screwed down high pressure withcrutch or butterfly handle screwed both ends for iron pipe 15 mm dia complete all as specified and directed
Supply & fix in repairs two way bib tap 15mm chromium plated complete all as specified and directed Make :Seiko/Cera/Parko
Supply & fix in repairs fancy type bib taps chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia complete all as specified and directed by Engineer in charge
Supply & fix in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms complete all as specified and directed
Supply & fix in repairs counter top viterious china wash basin white flat back size 550 x 400 mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets CP wastes and other fittings complete all as specified and directed
Supply & fix in repairs single lever tall pillar taps for counter top wash basin, chromium plated, cast copper alloy with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes 15mm dia complete all as specified and directed
Supply & fix in repairs 32mm dia chromium plated Bottle trap having minimum water seal of 25mm (Minimum weight 175 to 450grams) complete all as specified and directed
Supply & fix in repairs 32mm dia waste coupling of PTMT (half or full threaded) Minimum weight 32mm to 145gms/40mm to 160 gms) complete all as specified and directed
Supply & fix 32 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 Kgf/cm2 including making thread for fixing with waste coupling complete all as directed.
Supply & fix in repairs towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190 gms) complete all as specified and directed
Supply & fix in repairs PVC white flexible waste pipe in WHB/Sink complete all as specified and directed
Supply & fix PVC connections 15mm size with brass nut on both end washers of length 600mm complete all as specified and directed
Material & Labour for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise N.exc 100 sq.cm complete all as specified and directed
Material & Labour for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 100 sq.cm and n.exc 250 sq.cm complete all as specified and directed
Taking down drain pipes (any size or pattern), including all fittings, Tee, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed
Supply & fix PVC (SWR) pipes 110 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor complete all as specified and directed
Supply & fix PVC (SWR) pipes 75 mm dia single sockets, in any length rubber ring joints, laid in trenches or in floor complete all as specified and directed
Supply & fix PVC (SWR) 110mm dia bends any radius complete all as specified and directed
Supply & fix PVC (SWR) branch 110mm bore pieces, single ( single Y ) equal or unequal complete all as specified and directed
Supply & fix PVC (SWR) junction110mm bore single ( single Tee) equal or unequal complete all as specified and directed
Supply & fix PVC (SWR) 75 mm dia bends any radius complete all as specified and directed
Supply & fix PVC (SWR) junction 75 mm bore single ( single Tee) equal or unequal complete all as specified and directed
Supply & fix PVC (SWR) branch 75 mm bore pieces, single ( single Y ) equal or unequal complete all as specified and directed
Supply & fix PVC (SWR) 110mm bore vent cowl complete all as specified and directed
Supply & fix PVC (SWR) 75mm bore vent cowl complete all as specified and directed
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed
Material & Labour for Brickwork with subclass `B' bricks, straight or curved on plan exc 6mtr mean radius, built in cement mortar 1:6 complete all as specified and directed at any height
Taking down chowhkat without taking off shutter from frame n.exc 1.5 sqm each complete all as specified and directed.
Supply & fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed
Supply & fix factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd withheat moulded plain colour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for toprail and bottom rail panelling of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed
Supply & fix powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Supply & fix Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Supply only 3.0mm thick sheet glass ordinary quality and glazing exceeding 0.5 Sqm in each pane complete all as specified and directed
Material & Labour for 9 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work , aluminium works etc complete all as specified and directed.
Supply & fix in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and nut bolt,fixed complete all as specified and directed.
Supply & fix in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed
Supply & fix 125 mm size extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed
Supply & fix in repair aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 125mm complete all as specified and directed
Supply & fix 75 mm mild steel butt hinges medium weight, cold rolled complete all as specified and directed
Demolition stone slabs and tiles of any description or thickness in floors aprons laid and bedded and jointed in cement mortar complete all as specified and directed.
Material & Labour for granite slab (of any type) 20mm thick machine cut, laid over and including 20mm thick cement screed in cement mortar 1:4, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match with the shades of granite stone as in platforms/counter platform tops including cutting and mirror polishing etc., complete all as specified and directed,
Material & Labour for machine cut kota stone slab flooring 20 to 25mm thick in flooring but one piece as in treads of straircase etc over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing moulding complete, over and including 15 mm thick screed bed or bedding in CM 1:6 for laying floor finishes, complete all as specified and directed
All as item No 84 here in before but in one piece on vertical surface as skirting over and incl 10 mm thick rendering in CM 1:4 to receive kota stone/slab etc complete all as specified and directed
All as per item No 84 above here in before but 20 mm thick Machine cut Cudappah stone in floor over and including screed bed in CM 1:6 or in any position of any colour and shape complete all as specified and directed
Material & Labour for chequred cement concrete tiles with gray cement and pigment 20 cmx 20 cmx25 mm thick set and jointed and pointed in neat cement slurry in floors including 15 mm thick cement screed bed in CM 1:6 complete all as specified and directed
Rounding to edge of stone slabs one edge such as steps, counter platform and other similar situatiion complete all as specified and directed.
Dismantling wall and ceilihg boards (Fiber pulp, insulation etc or insulation boards) any thickness including cover fillets complete all as specified and directed.
Material & Labour for anodised aluminium snap grid ceiling with 19mm thick semi - perforated edge 60x60cm board in ceiling over over and including GI grid prelude XL 24 mm grid main runner height 37mm and secondary runner height 30mm including 2.6mm/2.8mm GI wire suspenders of suitable length as per manufacturers instructions complete all as specified and directed.
Taking down carefully old copper/Aluminium point wiring, fitting and fixtures complete such as switches,ceiling rose, pendenent, regulators, sockets etc removing unserviceable materials from site and making good disturbed surface etc complete all as specified and directed.
Taking down the existing unserviceable main switch, DBs of any type and capacity, sheet metal enclosure description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified and directed.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed
Taking down old unsv tubelight fitting/Recess Mounted fitting/Downlighter or ceiling mounted fitting and of any type complete all as specified and directed
Material & Labour for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC conduit minimum 20 mm dia concealed in wall/floor/ceilling and accessories etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) suitable for fixing modular switch socket & frame plate duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally with modular white cover plate with frame for mounting modular switches, sockets and fan regulators etc including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly complete all as specified and directed by Engineer in charge for the following :-
One light point controlled by one switch 6 Amp one way
One fan point controlled by one switch 5 Amp one way
One socket outlet 3 pin 5 amps same board
One socket outlet 3 pin 5 amps Independent board
Bell /buzzer point controlled by one push button indipendent with cables 1.5 sqmm size.
One light point controlled by two way switch.
All as per item No 89.00 here-in-before but wiring with 2.5 sqmm single core multi stranded copper condcutor, FRLS 1100 V grade PVC insulated but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm cable as earthwire complete all as specified and directed
All as per item No 89.00 here-in-before but wiring with 4.0 sqmm single core multi stranded copper conductor 1100 V grade PVC insulated but unsheathed single core multi stranded PVC insulated unsheathed copper conductor FRLS cable 1100 volts grade for 16 Amps power point on independent board and 4.0 sqmm cable as earthwire complete all as specified and directed
Supply & fix Switch 6 Amps Modular one Way, one module complete all as specified and directed by Engineer in charge.
Supply & fix Switch 16 Amps Modular one Way, one module complete all as specified and directed by Engineer in charge.
Supply & fix Modular socket 6 Amps, 2/3 pin combined 2 module Flush type complete all as specified and directed by Engineer in charge.
Supply & fix Modular socket 6/16 Amps, 2/3 pin combined 2 module flush type complete all as specified and directed by Engineer in charge.
Supply & fix Modular switch 2 way 6A, 1 module, complete all as specified and directed by Engineer in charge.
Supply & fix in repair Modular type Bell push, flush type, 6 Amp, 1 module complete all as specified and directed by Engineer in charge.
Supply & fix in repair PVC ceiling rose surface type three terminals type complete all as specified and directed by Engineer in charge.
Supply & fix in repair Buzzer/ ding dong AC 230 volts, 6 Amp single Phase in white /Ivory colour finish complete all as specified and directed
Supply & fix in repairs single pole and neutral enclosure with a metal two pin and earth plug and metal clad socket complete with one double pole MCB 20 Amps complete all as specified and directed. Make- Indoasian/Havells/Legrand
Supply & fix wall mounted LED Mirror light fitting extruded Polycarbonate housing high quality indoor batten LED tube 10 watt colour temperature 4000 K (2' long) lumen 1700 to 2000, PF> 0.90, THD less 10% diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement complete all as specified and directed by Engineer in charge.
Supply & fix LED tube light 4' along with fixture, 20 W complete all as specified and directed
Supply & fix LED down lighter 2'x2', 40 W complete all as specified and directed
Supply & fix Post top lantern light fitting 70 Watt with cast aluminium spigot,spun al power coated top cover, AL. PDC heat sink, opel PC diffuser and clear acrylic, IP 65 and with system efficacy of 80lm/W with all connected items complete all as specified and directed by Engineer in charge.
Supply & fix wall mounted high quality indoor wall bracket light cylinderical/Oval Shape aesthetically designed in wooden housing, glass and B22/E27 Lamp Holder with 9 Watt bulb temp range 4000k to 6500k as per site requirement connection with three core flexible copper wire complete all as specified and directed by Engineer-in- Charge.
Supply and fix LED street light 35/36 W IP 65 complete all as specified and directed
Taking down existing fan and Supply & fix new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and exisitng C/F deposited to MES store yard complete all as specified and directed
Taking down existing Exhust fan and supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and exisitng C/F deposited to MES store yard complete all as specified and directed
Taking down existing geyser and Supply and fixing of Electric Storage water heater of capacity 25 Ltrs of Five star rating, AC 230 Volts with four numbers nut bolts duly groutted in walls including all standard accessories with flexi connection pipe of 450 mm size, glass line tank, NRV complete all as specified and directed
Supply & fix sheet metal enclosure Vertical Type TPN DB 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system, MCCB as incomer complete all as specified and directed
Supply & fix sheet metal enclosure of SPN 8 way DB with 200 Amps rated bus bar 240 volts Double door with magnitic locking system complete all as specified and directed
Supply and fixing 415V 10 KA C curve miniature circuit breaker (MCB) TPN 100 Amp in the DB complete with connection testing and as specified and directed.
Supply & fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA Capacity complete all as specified and directed
Supply & fix MCB SP 6 to 32 amps, C curve 10kA, 240 V complete all as specified and directed
Supply & fix MCB SPN 63 Amps, C curve 10kA, 240 V complete all as specified and directed
Material & Labour in repair for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 2.5 sqmm 1100 volt grade drawn into and including PVC conduit of size 25 mm dia including 2.5 sqmm PVC multi standard copper conductor FRLS cable in green colour for contineous earthing complete all as specified and directed by Engineer in charge.
Material & Labour in repair for sub main wiring with four single core multistranded PVC insulated copper conductor FRLS cable of size 4 sqmm 1100 volt grade drawn into and including PVC conduit of size 25 mm dia including 4 sqmm PVC multi standard copper conductor FRLS cable in green colour for contineous earthing complete all as specified and directed by Engineer in charge. Note: Four single core cable, earth wire and conduit / casing capping shall be measured as one length.
Material & Labour in repair for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to 4.0 mm dia galvanised earth lead wire by means of nuts botls check nuts and GI washers including PCC pit in PCC 1:2:4 type B1 RCC cover 20mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitable size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing resulot and common salt & charcoal including excavation, earthwork etc in any type of starta complete all as shown in electrical plate No 3 as specified, gI wire suitable size and lenth for continuity earth wire from test point to main distribution board complete all as specified and directed. Note : Rate for achieving required depth by compressor machine if required is deemed to be included in item unit rate.
Supply & fix GI strip 32mm x 6 mm buried in ground complete all as specified and directed
BHABA CONSTRUCTION (BID ID -3386597)
M/S JAYCONSTRUCTION CO (BID ID -3387541)
M/S SANDEEP CONSTRUCTION COMPANY (BID ID -3387231)
SAMBHAJI D JARANDE (BID ID -3387464)
S V CONSTRUCTION (BID ID -3387523)
BHARDWAJ ENTERPRISES (BID ID -3387015)
ShreHari Civil Enginneering and Contractors (BID ID -3387022)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .