Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹35.8 L+₹3.5 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Other than being Lowest | |
| 3 | L3₹38.0 L+₹5.7 L (17.6%)Rejected-Finance 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L3 | Rejected-Finance Other than being Lowest | |
| 4 | L4₹39.6 L+₹7.3 L (22.6%)Rejected-Finance 301 A WINGH AZIZ APARTMENT WAZI MOHALLA OLD PANVEL NAVI MUMBAI 410 206 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410206 | L4 | Rejected-Finance Other than being Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not having Category c (i) |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPLACEMENT OF BER AC PLANTS AND EQUIPMENT INCLUDING ALLIED WORKS AT BUILDING A 14 INS VAJRABAHU AT NAVAL DOCKYARD UNDER GE NW KUNJALI COLABA MUMBAI 2ND CALL
2022_MES_537201_2
8480/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KUNJALI
Class D
7 documents required · 7 mandatory
₹500
Yes
GE (NW) Kunjali
₹77,000
Yes
2 Dec 2022
28 Sept 2022
24 Oct 2022
28 Sept 2022
22 Oct 2022
8 Oct 2022
28 Sept 2022 - 6 Oct 2022
Amount
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces complete all as specified and as directed by Engineer-in-Charge
Taking down carefully submain wiring with aluminum conductor cable 4/5/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc complete all as specified and as directed by Engineer-in-Charge
Material and labour for point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI marked and drawn through & including pvc conduit, ISI marked in wall including terminal box and one PVC insulated & insheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly all as specified.
One light point controlled by one 5A switch
One fan point controlled by one 5A switch
One 5A switch socket combination on independent board
One 5A switch socket combination on same board
Material and labour for point wiring complete with 4 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 Volts FRLS grade ISI marked and drawn through & including PVC non metallic conduit, ISI marked, not less than 25mm, including one PVC insulated & unsheathed multistranded copper conductor of size 4 Sq. mm as earth co tinuity conductor connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge
Material and labour for point wiring complete with 2.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI marked and drawn through & including PVC non metallic casing and capping, ISI marked, width not less than 25mm, double lock, with PVC non metallic ISI marked terminal boxes, fixed on wall/surfaces including one PVC insulated & unsheathed multistranded copper conductor of size 2.5 Sq. mm as earth continuity conductor connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular surface mounting box suitable for 12 modules of make Legrand cat part No 689021 or as approved by GE complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular white cover plate suitable for 12 modules with frame complete all as specified and as directed by Engineer-in-Charge. make Legrand cat part No 673262 or as approved by GE.
Supply and fixing modular box suitable for 8 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular white cover plate suitable for 8 modules with frame complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular box suitable for 3 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular white cover plate suitable for 3 modules with frame complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular flush box suitable for 6 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular white cover plate suitable for 6 modules with frame complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular flush box suitable for 1 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular white cover plate suitable for 1 modules with frame complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular switch 1 way 6A complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular switch 1 way 16A complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular socket, 6A - 2/3 pin combined 2 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular socket, 16A - 2/3 pin combined 2 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fixing modular fan step regulator 120 w 2 modules complete all as specified and as directed by Engineer-in-Charge
Supply and fix ceiling rose surface bakelite three terminal of size 50 x 24 mm.240 Volts AC complete all as specified and as directed by Engineer-in-Charge
Material and labour for submain wiring including earth wire connected to common earth as earth dolly with the following sizes of FRLS PVC insulated, unsheathed stranded copper conductor, 1100V grade, LT, single core cable drawn through & including PVC non metallic conduit ISI marked, not less than 25mm, complete all as specified and as directed by Engineer-in-Charge
2x4.0 sq.mm+1x2.5 sq. mm earth wire
2x6.0 sq.mm+1x4. sq. mm earth wire
Supply and fixing sheet metal enclosure SPN DB 12 Way ,240V with 200A busbar, double door type IP-42 protection suitable for housing MCB's including dummy plates all as specified and directed by EIC. Make: Legrand at No. 507642 and equvilent make of GE/Schneider.
Supply and fixing MCB SP 10 A, 10 KA, class 'B', ISI mark of make legrand cat part No 408590 and equvilent make of GE/Siemens/Schneider)
Supply and fixing MCB SP 32 A, 10 KA, class 'B', ISI marke of make legrand cat part No 408595 and equvilent make of GE/Siemens/Schneider)
Supply and fixing MCB 2P C 40A 10KA, class 'C', ISI marke of make legrand cat part No 408637 and equvilent make of GE/Siemens/Schneider)
Supply and fixing LED light fitting 36 W, 230V, surface mounting, and high transluscent diffuser including wire from ceiling rose to fitting including takingdown of old fittings complete all as specified and as directed by Engineer-in-Charge
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 A complete all as specified and as directed by Engineer-in-Charge
Dismantling of existing 6x7.5 TR unserviceable central AC plant with compressor, condensor motor including pipes and cooling tower, cables including ducts complete all as specified and as directed by Engineer-in-Charge
Supply, installing, testing and commissioning of factory assembled, water colled type, indoor type ductable package type AC plant (capacity 6x8.75 TR, 3 working and 3 standby) with all equipments and accessories, complete and comprising of following:- (a) Package unit each of Min 8.75 TR capacity (b) Hermetically sealed scroll type compressor with microprocessor based control with R-407 Refrigerant Gas, electrically operated on three phases, 415 volts, 50 Hz, Ac supply, complete with suction & discharge shut off valve, automatic capacity control with thermostat & solenoid valves built in suction strainer, oil pump, hot gas muffler, crank case, heat wheel, oil pressure, safety switch etc (c) Gauge panel complete with HP/LP cut off, oil safety switch suction discharge, oil pressure gauge. (d) shell & tube water cooledcondensor (e) Cooling coil of copper tube with aluminium fins. (f) Heating kit, trip type arrangement in blank to serve as reheater complete with monsoon air conditioning (dehumidifier). (g) Blower for weather proof complete with suitable electrical motor TEFC squirrel cage motor for operation on 415V, 3 phases, AC supply with V belt guard. (h) Expansion valves & pilor solenoid valves. (j) Necessary copper piping for liquid line complete with fittings valves etc. (k) First charge of non CFC refrigerant (R407C) & oil for the complete plant. (l) One set of flow switch in condensor water line. (m) Suitable foundation/ arrangements as per manufacturer's instruction for installation of the plant and as directed by the GE. (n) Any other equipment/ accessories/ parts/ components as recommended by the manufacturer's.
Supplying, installing, commissioning and testing of FRP induced draft round/ rectangular type counter flow cooling tower of capacity 30 TR supported over hot dip galanised steel structure fitted with axial flow fan, direct driven, operated with 3 phase 415 V AC supply PVC/Polpropylene fills/Nozzels with maximum allowable temperatura 50 degree centigrade, drift losses 0.005% of water: circulation with suitable foundation and float valve of suitable size complete all as specified. Make mihir or equivalant to advance make Model No 10TM-54
Supply, installing commissioning and testing of Monoblock centifungal pump set of capacity LPS 4.9 to 9.2 Head 10 mtr to 26 Mtr for condensor water circulation suitable for 433 AC supply and job including suitable foundation as per manufacturers instructions and as approved by the GE, neoprene rubber antivibration ribbed pads complete all as specified. Make : Kirloskar Model No KDI 325+ or equivalent as approved by GE.
Supply and laying MS pipes, medium grade 65mm bore with and including all fitings, laid in floors or fixed to walls or ceiling etc. Complete all as specified and directed.
Supply and laying MS pipes, medium grade 80mm bore with and including all fittings, laid in floors or fixed to walls or ceilings etc. Complete all as specified and directed
Supply and laying MS Pipes, medium grade 50mm bore with and including all fittings, laid in floors or fixed to walls or ceilings etc. Complete all as specified and directed.
Supply and laying MS Pipes, medium grade 40mm bore with and including all fittings, laid in floors or fixed to walls or ceilings etc. Complete all as specified and directed.
Supply and fix 65mm bore waffer type butterfly valve complete with companion flanges, nuts, bolts gaskets etc and confirming to PN-16 ratings, all as specified and directed.
Supply and fix 80mm bore waffer type butterfly valve complete with companion flanges, nuts, bolts gaskets etc and confirming to PN-16 ratings, all as specified and directed.
Supply and fix 50mm bore waffer type butterfly valve complete with companion flanges, nuts, bolts gaskets etc and confirming to PN-16 ratings, all as specified and directed.
Supply and fix pot stainer CL 80mm complete with companion fanges ruts, bots gaskets etc and Each confirming to PN16 ratings, all as specified and directed.
Supply and fixing waffer type dual plate NRV valves of size 65mm bore check valve complete with companion flanges nuts, bolts gasketes etc and conforming to PN16 rating all as specified
Supply, assembly and erection of 22 guage Gl sheet with TDF flange, rectangular/square duct made out of 'L' shaped hollow profile duly factory boxed incl all accessories such as corner, cleat carriage bolt, gasket and appropriate sealent on longitudinal joints et complete all as specified.
Supply, assembly and erection of 24 guage Gl sheet with TDF flange, rectangular/square duct made out of 'L' shaped hollow profile duly factory boxed incl all accessories such as corner, cleat carriage bolt, gasket and appropriate sealent on longitudinal joints et complete all as specified.
Supply and fixing grill made out of aluminium powder coated for supply air return air all as specified
Material and labour strip heater 2 KW complete all as specified and directed. Note: The quoted rates shall also be deemed to include the cost of wiring between control contactor to strip heaters with suitable capacity of PVC copper conductor cable including PVC conduit and its accessories etc.
supply and fixing fresh air grill made of GI 20 gauge with blade with volume control damper complete all as specified.
Material and labour for fire damper made out of GI sheet 16 gauge with fusible plug complete all as specified and directed.
Supply and fixing 25mm thick resin bonded fiber glass wool crown covered with 24 gauge perforated aluminim sheet cover chicken wire mesh for acoustic lining complete all as specified and as directed by Engineer-in-Charge
Material and labour for duct insulation with 50 mm thick resin bonded fibre glass wool of density 24 Kg/Cum, with factory laminated aluminium vapour barrier and including the following:- (a) Material and labour for cleaning the duct surface (to be insulated) by crapping carefully with wire brush etc to trake the surface completely free of misscale, dirt, dust grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Material and labour for applying rubber based adhesive CPRX compound. (c) Material and labour for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide to make the insulation leakproof. (d) Material and labour for securing the insulation with and including mechanically fastened nylon/ steel straps of size 50mm at maximum intervals of 1.2 mtr.
Supply and fixing GI pipe 40mm medium grae for drain water all as specified.
Supply and fising Themostat suitable for 8.75 TR complete all as specified.
Supply and fixing industrial type pressure guages made out of SS 304 material, SS sipon shall be factory insulated with closed cell elastomeric insulation in tubing form, pressure guages shall be factory fitted with a ball valve complete all as specified.
Supply and fixing cable tray GI 150mm width for laying control cable complete all directed by Engr-in-Charge.
Supply and fixing Themometer pin type complete all as specified.
Supply, install and testing 5000 ltrs capacity PVC tank float valves, sippon scalled guage drain overflow, makeup water connections etc complete all as specified and directed.
Supply and laying 3 core, 2.5 Sqmm, PVC insulated armoured & PVC sheathed with copper conductor, heavy duty, LT 1100 Volts grae cable conforming to IS-1554 Part-I including testing, complete all as specified for condensing unit complete all as specified and directed.
-Ditto- all as per item No 57 above but 3 core 4 sqmm
-Ditto- all as per item No 57 above but 4 core 10 sqmm
Material and labour earthing complete with galvanised steel earth plate electrode 600mm x600mm x 6.00 mm thick, burried directly in ground / vertically (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the earth plate not less than 1.5 Mtr below normal ground level connected to galvinised earth strip of size of 32mm x 6mm complete by means of bolts and nuts check nuts and washers of galvinised iron or steel protected by providing 40 mm bore Gl Pipe light grade and connected to main feeder pillar board including waterring arrangements with 20 mm bore Gl pipe medium grade PCC 1:2:4 type B-1 chamber, funnel, wire mesh, RCC 1:24, 50 mm thick cover. reinforced with XPM, necessary excavation in any type of soil returing filling removal of surplus spoil, charcoal and salt filling, complete all as shown in electrical plate No 3 of MES Sch part-1 connected to earthing test point, all as specified, indicated and testing on completion. Note Length of 32mm x 6 mm earth lead & protection pipe upto 7,5 Mtr shall be deemed to be included in the quoted rate
Supply and fix AL strip 32x6 mm fixed on wall, floor and laid in trenches, complete all as specified and directed.
Dismantling of wall and celling boards (fibre, pulp, insulation) or insulation boards, false ceiling, wall panneling & partation boards bonded wool, blanket slab incl aluminium grid frame work complete all as specified and as directed.
Supply and false ceiling with powder coated exposed GI grid suspension system a grid of 600mm X 60mm. Grid of modular size 600mm X 600mm shall be supported by 4 mm dia G.I. wire from purling/ soffit with and including 4 mm thick high pressure steam cured non asbestos fiber cement designer celling board (Density >1200Kg/ Cum) of size 595 mm X 595mm complete all as specified and directed Engg-in-charge.
Material and labour rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth (with out using extra cement) etc complete all as specified and directed Engg-in-charge.
Material and labour for preparing new plastered surfaces of walls and applying two coats of oil bound distemper with priming plastered and other surfaces with alkali resistant primer with 3mm thick wall care putty on plastered surfaces complete all as specified and directed.
Material and labour for preparing of old painted surfaces of wood or wood based surfaces over 10 cms width or girth and applying one finishing coat of synthetic enamel paint on wooden surfaces complete all as specified and directed.
somnath engineering corporation
BRITE INDUSTRIES
AIRFRAME
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .