Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹38.6 LAccepted-AOC 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | l1 | Accepted-AOC Aoc | |
| 2 | l2₹38.8 L+₹12,039.83 (0.31%)Rejected-Finance | l2 | Rejected-Finance l2 | |
| 3 | l3₹38.8 L+₹15,923.65 (0.41%)Rejected-Finance | l3 | Rejected-Finance l3 | |
| 4 | Not Admitted-Fee/PreQual/Technical RAJAPUR ULUBERIA HOWRAH | HOWRAH | WEST BENGAL | 711101 | - | Not Admitted-Fee/PreQual/Technical Others-withdrawn |
Tender Value
₹38.8 L
EMD Value
₹77,700
Closing Date
5 Dec 2025, 10:10 amClosed
Block Development Officer, APD-II Dev Block
Block Development Officer, Alipurduar-II Block Development Office, P.O. - Jasodanga and Dist. - Alipurduar, PIN- 736208, West Bengal.
Construction of 5 nos Additional Class Room at Khapsadanga High School under Alipurduar-II Development Block.
2025_ZPHD_946774_1
APD II NIT 21 e BDO APD 2025 26
Open Tender
CIVIL WORKS
Percentage
Alipurduar II Development Block
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,000
₹77,700
8 Apr 2026
13 Nov 2025
8 Dec 2025
13 Nov 2025
5 Dec 2025
13 Nov 2025
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (Payment to be made on measurement of finished quantity).
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Cement Concrete with 30mm down graded Shingles excluding shuttering (1:3:6) in foundation :
Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips (20mm down excluding shuttering and reinforcement,if any in ground floor. As per relevent I.S. Codes.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. (b) EXtra for works beyound the roof of ground floor/ initial 4.0m . (i) Upto 4th floor roof in each addl. Floor
Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, columns, lintels curved or staight including fitting fiXing and striking out after complection of works. (up to 1st floor) 25 mm. to 30 mm. thick wooden shuttering without staging in foundation as per decission & direction of E-I-C.
25 mm. to 30 mm. thick wooden shuttering as per decission & direction of E-I-C.In Ground Floor.
Brick work in 1st class bricks in cement mortar (1:4) in foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in Ground floor.
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground floor). a) with 4:1 cement mortar i) 15 mm. thick plaster - Lum Sum ( Details in bill )
b) With 4:1 cement mortar i) 20 mm. thick plaster - Lum Sum ( Details in bill )
Antitermite treatment to the top surface of the consolidated earth within the plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration ) with water by weight at the rate of 5 litres per sq.m of the surface before sand bed or sub-ghade is laid.Holes upto 50 mm to 75 mm deep at 150 mm centre to centre both ways shall be made with 12 mm diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313(Part -II) 1981.
Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration ) with water by weight including drilling vertically 12 mm dia holes at the junction of the floor and wall at 300 mm interval to reach the soil below using hand operated pump to squirt chemical emulsion into the holes at the rate of one litre per hole.The hole shall be sealed after operation to match the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code IS -6313(Part-III) 1981
Labour for chipping of concrete surface befor taking up plastering work
Artificial stone in floor dado stair case etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement ( as necessary ) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 Kg / Sq.M all complete including all materials and labour. In ground floor 3 mm thick topping ( High polihsing grinding on this item is not permitted with ordinary cement using grey cement 25 mm thick
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured ( matt finish ) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly complete as per manufacturer's specificaion and as per direction of EIC two coat Ground floor i) external surface of ground floor b) Two coats - Lum Sum ( Details in bill )
Protective decorative acrylic exterior emulsion paint of approved quality as per manufacturer's specificaiton and as per direction of Engineer in charge to be applied over acrylic primer as required. the rate includes cost of material labour scaffolding and all incidental charges but excluding the cost of primer. In ground floor two coat Normal Acrylic emulsion
(a) M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows, railing etc. fitted and fiXed with necessary screws and lugs in ground floor.
Acrylic Distemper to interior wall ceiling with a coat of solvent base interior grade acrylic primer (as per manufacturer's specification ) including cleaning and smoothening of surface two coats
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]Red Variety(ii) 30 mm. thick
Wood work in door and window frame fitted and fiXed complete including a protective coat of painting at the contact surface of the frame. At 1st floor.(The quantum should be corrected upto three decimals) Ground floor
Panel shutter of door and window as per design having tongued and groove half lap joint as per direction of the E-I-C including fitting and fiXing shutter in position,but excluding the cost of hinges and other fittings in Ground floor. B) Shutter with 35 mm thick panels 30-45 Cm. Sisu, Gamar, Champ, Badam, Bhola, Morga, Hallak
Anodised aluminium skeleton bolt of approved quality manufactured from extrudedsectionconforming to I.S: specification (I.S: 204/74) fittedand fixed with cadmiim plated screws. (iv) 300mm long x 12mm dia. bolt.
i) Ironhaspbolt of approvedquality fittedand fixedcomplete (oxidised)with 16mm dia rod with centre bolt and round fitting. (c) 300mm long.
PART - B = FIRST FLOOR Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips (20mm down excluding shuttering and reinforcement,if any in ground floor. As per relevent I.S. Codes.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. (b) EXtra for works beyound the roof of ground floor/ initial 4.0m . (i) Upto 4th floor roof in each addl. Floor
Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, columns, lintels curved or staight including fitting fiXing and striking out after complection of works. (up to 1st floor) 25 mm. to 30 mm. thick wooden shuttering as per decission & direction of E-I-C.In First Floor
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in First floor
Wood work in door and window frame fitted and fiXed complete including a protective coat of painting at the contact surface of the frame. At 1st floor.(The quantum should be corrected upto three decimals)
Panel shutter of door and window as per design having tongued and groove half lap joint as per direction of the E-I-C including fitting and fiXing shutter in position,but excluding the cost of hinges and other fittings in 1st floor. B) Shutter with 35 mm thick panels 30-45 Cm. Sisu, Gamar, Champ, Badam, Bhola, Morga, Hallak
Anodised aluminium skeleton bolt of approved quality manufactured from extrudedsectionconforming to I.S: specification (I.S: 204/74) fittedand fixed with cadmiim plated screws. (iv) 300mm long x 12mm dia. bolt.
i) Ironhaspbolt of approvedquality fittedand fixedcomplete (oxidised)with 16mm dia rod with centre bolt and round fitting. (c) 300mm long.
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground floor). a) with 4:1 cement mortar i) 15 mm. thick plaster - Lum Sum ( Details in bill )
b) With 4:1 cement mortar i) 20 mm. thick plaster - Lum Sum ( Details in bill )
Artificial stone in floor dado stair case etc with cement concrete (1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement ( as necessary ) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 Kg / Sq.M all complete including all materials and labour. In ground floor 3 mm thick topping ( High polihsing grinding on this item is not permitted with ordinary cement using grey cement 25 mm thick
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]Red Variety(ii) 30 mm. thick
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured ( matt finish ) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly complete as per manufacturer's specificaion and as per direction of EIC two coat Ground floor i) external surface of First floor b) Two coats - Lum Sum ( Details in bill )
Protective decorative acrylic exterior emulsion paint of approved quality as per manufacturer's specificaiton and as per direction of Engineer in charge to be applied over acrylic primer as required. the rate includes cost of material labour scaffolding and all incidental charges but excluding the cost of primer. In ground floor two coat Normal Acrylic emulsion
Acrylic Distemper to interior wall ceiling with a coat of solvent base interior grade acrylic primer (as per manufacturer's specification ) including cleaning and smoothening of surface two coats
(a) M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows, railing etc. fitted and fiXed with necessary screws and lugs in ground floor.
PART - C = SECOND FLOOR Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips (20mm down excluding shuttering and reinforcement,if any in ground floor. As per relevent I.S. Codes.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. (b) EXtra for works beyound the roof of ground floor/ initial 4.0m . (i) Upto 4th floor roof in each addl. Floor
Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, columns, lintels curved or staight including fitting fiXing and striking out after complection of works. (up to 1st floor) 25 mm. to 30 mm. thick wooden shuttering as per decission & direction of E-I-C.In First Floor.
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in First floor
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary (ground floor). a) with 4:1 cement mortar i) 15 mm. thick plaster - Lum Sum ( Details in bill )
b) With 4:1 cement mortar i) 20 mm. thick plaster - Lum Sum ( Details in bill )
stage.html
html • 0.05 MB
technical_2252334.pdf
techsummary_2252334.pdf
BOQ Comparative Chart
xlsx
finsummary_2252334.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.03 MB
BOQ_2252334.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .