| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.5 L+₹56,023 (4.70%)Rejected-AOC | L2 | Rejected-AOC Not Accepted | |
| 3 | L3₹12.5 L+₹59,796 (5.02%)Rejected-AOC 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L3 | Rejected-AOC Not Accepted | |
| 4 | L4₹12.7 L+₹77,382 (6.49%)Rejected-AOC | L4 | Rejected-AOC Not Accepted | |
| 5 | L5₹14.0 L+₹2.1 L (17.4%)Rejected-AOC | L5 | Rejected-AOC Not Accepted |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
18 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Mumbai
Garrison Engineer North Mumbai Military Engineer Services Santacruz East, Mumbai 400029
REPAIR/REPLACEMENT OF PERIMETER AND BUILDING SECURITY LIGHTS AND ALLIED WORKS UNDER GE (N) SANTACRUZ
2024_MES_647250_1
8183/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer North Mumbai
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer North Mumbai
₹28,000
Yes
18 Jun 2024
20 Mar 2024
20 Apr 2024
20 Mar 2024
18 Apr 2024
4 Apr 2024
21 Mar 2024 - 28 Mar 2024
Amount
Supply and Lay LT UG XLPE insulated, heavy duty, 1100 V grade electric cable with aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 16 sqmm x 2 core, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge. Note : Earthwork excavation, DWC pipe for cable protection shall be measured and paid separately in their respective items Make: Cable Corporation of India (CCI)/ Asian Cable Co, Chattisgarh/ Finolex/ Polycab/ Gloster/Universal/ RPG Cables Ltd , Thane/ Havells India Ltd/ RR Kabel/ KEI Industries Ltd(KEI)
-do- same as Item no. 1 above but of size16 Sqmm 4 Core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for laying UG cables and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Supply and lay double wall corrugated (DWC) HDPE pipe dia 50/38mm, as per IS-16205 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge Make : TELEREX 450N or equivalent as approved by GE
Supply, install, test and commission LED Building security light fitting 35 watts, rating, separate individual peanut plated lens and aluminium reflector housing made of LM6 pressure die cast aluminium. Optical cover toukghned glass only, impact resistance>IK05 IP protection not less than IP66, protection should be class I vibration as per IEC 60598, product standard IS 10322/IEC60598, all the component such as driver, surge protector should be of same make. Driver should be moulded type with operating voltage 140V270V, driver frequency 50 Hz power factor >0.9, moulded type weather proof construction with seprate surge protection device 5 KA rating and separate connector block for termination of incomming cable connection, including taking down old unserviceable LED light, all as specified and directed by Engineer-in-Charge. Make - Osram / Phillips / General electric (GE)/Crompton
Supply, install, test and commission LED street light fitting 90 watts, rating, separate individual peanut plated lens and aluminium reflector housing made of LM6 pressure die cast aluminium. Optical cover toukghned glass only, impact resistance>IK05 IP protection not less than IP66, protection should be class I vibration as per IEC 60598, product standard IS 10322/IEC60598, all the component such as driver, surge protector should be of same make. Driver should be moulded type with operating voltage 140V-270V, driver frequency 50 Hz power factor >0.9, moulded type weather proof construction with seprate surge protection device 5 KA rating and separate connector block for termination of incomming cable connection, including taking old unserviceable LED Light, all as specified and directed by Engineer-in-Charge. Make - Phillips/ Osram / Crompton/ General electric (GE)
Supply, install, test and commission LED street light fitting 70 watts, rating, separate individual peanut plated lens and aluminium reflector housing made of LM6 pressure die cast aluminium. Optical cover toukghned glass only, impact resistance>IK05 IP protection not less than IP66, protection should be class I vibration as per IEC 60598, product standard IS 10322/IEC60598, all the component such as driver, surge protector should be of same make. Driver should be moulded type with operating voltage 140V-270V, driver frequency 50 Hz power factor >0.9, moulded type weather proof construction with seprate surge protection device 5 KA rating and separate connector block for termination of incomming cable connection, including taking old unserviceable LED Light, all as specified and directed by Engineer-in-Charge. Make - Phillips/ Osram / Crompton/ General electric (GE)
Supply and errect 7 meter long hot dipped galvanised OCTAGONAL street light pole with one single light bracket for street light. The bottom of pole shall be 130mm dia and top shall be 70mm dia with 3mm thickness, high tensile strength conforming to BS EN 10025, base plate shall be 220x220x112mm with 4 nos of anchor bolt 'J' type 700 mm long 20mm dia with nut washer and bolt shall be inserted to RCC footing. The pole shall have internal inbuilt junction box including 3 phase bus bar and one 6 Amp MCB complete including necessary eartwork excavation in hard/dense soil, RCC M-20 concrete footing with reinforcement,as per manufacturer drawing formwork etc complete all as specified and directed. Make- India Tube and Co/ India Electric Poles Mfg Co, Maharashtra/ Bombay Tubes/ The National Tubing Company, Kanpur/ Kalinga Tubes/ Singh Profile, Pune
Supply and fix in replacement of street light bracket arm, fabricated out of 40mm dia GI tubing, medium grade, 1.2 meter long, bend to shape, fixed on pole with including 2 pair of clamps of fitted with suitable size nuts, bolts washers including one coat of synthetic enamel paint complete all as specified and as directed.
Supply and fix in repairs cable junction box made out of thermoplastic sheet, IP66 protected outdoor installation of size 200 x 160 x 98mm with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32- 2 Nos), fixed on poles with flat iron clamps of size 25x3mm, nut, bolt, washers etc including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and provision of one single pole MCB 6 amps for controlling light etc complete all as specified and as directed by Engineer-in-Charge. Make : Sintex GS-JB-2014 / K-8250 of Hensel or equivalent in National
Supply and fixing 3 core, PVC insulated and unsheathed, 1100 volt grade, multicore cable, 1.5 sqmm with stranded copper conductor cable, drawn inside pole as required with making necessary holes on bottom and top of pole from looping box to security light fitting etc, including taking down old unserviceable complete all as specified and as directed by Engr-in-charge. Make: Finolex/ Plaza/ Anchor/ Havells/ Polycab Note : The cost of conduit pipe and clamps, to be fixed in walls, is deemed to be included in quoted rate.
Material and labour for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to plate with GI earth strip 32 x 6mm, upto 7.5 m long from earth point to test point and other end connected to control/ panel / equipment, laid under floors/plinths or fixed on walls or concealed in wall etc by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel with provision of charcoal & common salt packed upto minimum 150 mm layer all around the earth plate, all as shown in electrical plate No.3 of MES schedule Part I, 2009 with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI 15 mm bore medium grade pipe and CI funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix single pointed air termination aluminium rod, 12mm dia, 300mm long including taking down old unserviceable aluminium rod, all as specified and directed by Engr-in-Charge.
Supply and fix aluminium strip of 25 x 3.15mm , including taking down of old unsercivable aluminium strip, complete all as specified and directed by Engr-in-Charge. Note : Rate for Necessary insulator for fixing of strip is deemed to be included in the quoted rate.
Material and labour for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos 8mm dia 25mm long hexagonal screws, including taking down old unserviceable complete all as specified and as directed by Engineer-in-Charge.
Supply and fix galvanized iron pipe, medium grade, 25mm duly grouted on the roof for fixing Air terminal etc, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company
Supply and fix galvanised iron pipe, light grade, 40mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company
Material and labour for cutting or cutting the existing Bitumen Road /hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6 type C1 using 20mm graded aggregate complete all as specified and directed.
Refixing / Relaying of existing disturbed aluminium strip at any location and size to its original places with help of fixing screw / insulator and other acessories etc all as specified and directed by Engr-in-Charge.
Supply and fix decorative poles for street light with single arm, aesthetically designed mild steel poles with powder coated finish compatible for LED Post top range, plasma cut & duly chamfered opening window for terminal connections & mounting accessories 3.5 mtr height all as specified and directed by Engr-in-Charge. Make Shakti Cat Prt No- SZDPPT or in equivalent as approved by Engr-in-Charge. Note: Rates for Necessary, excavation in hard/soft soil, foundation of poles PCC 1:4:8 , nuts, screws is deemed to be included in the quoted rate.
Supply and fix , Low voltage normal duty Power capacitor of 25 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens
Supply and fix , Low voltage normal duty Power capacitor of 10 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens
Supply and fix , Low voltage normal duty Power capacitor of 5 KVAr, 3 phase, 50 Hz, 440 volts, having long life expectancy upto 100000 hrs, self healing type, Standard Duty Box type capacitors, should be inbuilt over pressure disconnector, shock hazard protected terminals, including taking down old unserviceable power capacitor all as specified and directed by Engr-in-Charge. Make- Schneider, L&T, Siemens
Supply & fix LED street light Celesta 40W warm white, with automatic brightening from 25% to 100% of rated wattage on sensing of movement/ occupancy, Antiquely designed aesthetically appealing landscape cum street light, made from aluminium housing, clear polymer diffuser to provide uniform and pleasant light output all as specified and directed by Engr-in Charge. Make- Shakti Cat Prt No- SZPSCPD040 or in equivalent as approved by Engr-in-Charge.
Refixing/Relaying of GI strip 25mm/ 32mm with necessary screw and other accessories all as specified and directed by Engr-in-Charge.
Note: Deduct Credit for demolished / dismantled material of Rs. (-) 39,205.00 (Minus) as listed in Schedule of Credit. Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
Radha Engineering Services
EVEREST POWER CONTROL ENGINEERS
AIRDOT ENGINEERING
Chaudhary Enterprises
ELECTRO ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .