| 1 | L1₹39.8 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.7 L+₹1.7 L (4.14%)Rejected-Finance MALANCHA ROAD KHARAGPUR 721304 DIST WEST MIDNAPORE WEST BENGAL | KHARAGPUR | WEST MIDNAPORE | WEST BENGAL | 721304 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹44.2 L+₹3.2 L (7.76%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹44.7 L+₹3.7 L (8.92%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹44.7 L+₹3.7 L (9.04%)Rejected-Finance NIL | THE NILGIRIS | TAMIL NADU | 638451 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
23 Nov 2020, 6:00 pmClosed
Shri R Durga Shyam, EE, GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIRS/MAINT OF BORE WELL, CONTROL PANELS, PUMPS, SUPPLY OF WATER TREATMENT CHEMICALS FOR ALL WATER SUPPLY INSTALLATIONS AND CI/GI DISTRIBUTION WATER PIPE LINES AND ALLIED WORKS AT AF STN KKD AND DDK RANGE UNDER GE (AF) KALAIKUNDA
2020_MES_367586_2
8586/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹74,000
Yes
22 Mar 2021
16 Nov 2020
25 Nov 2020
16 Nov 2020
23 Nov 2020
17 Nov 2020
Amount
Supply only Calcium hypochlorite based granular disinfectant for water treatment and packed in 45 kg plastic drum. Make :- Puri Chlor / Declibac Technologies /Potter & Watts / Brio Zing or equivalent as approved by GE. Note :- 1. Approval of chemical ( calcium hypochlorite) shall be given after verification of test certificates and their chemical analysis , strength in terms of quqntity of chlorine content. 2. The brand/make of chlorination chemical must be certified by Govt. Laboratory and confirming compliance of specification , suitable for drinking water.
Supply only dosing pump roller assembly suitable for existing dosing pump complete all as specified and directed by EIC . Make of roller assembly :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new roller assembly as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Roller assembly for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump tube suitable for existing dosing pump complete all as specified and directed by EIC . Make of Pump Tube :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new pump tube as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Pump tube for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump weighted suction line strainer suitable for existing dosing pump complete all as specified and directed by EIC . Make of Injection check valve :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new weighted suction line strainer as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of weighted suction line strainer for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump Injection check valve suitable for existing dosing pump complete all as specified and directed by EIC . Make of Injection check valve :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new Injection check valve as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of Injection check valve for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump white suction /discharge tubing suitable for existing dosing pump complete all as specified and directed by EIC . Make of white suction /discharge tubing :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new white suction /discharge tubing as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of white suction /discharge tubing for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump check valve duckbill only suitable for existing dosing pump complete all as specified and directed by EIC . Make of check valve duckbill :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new check valve duckbill as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of check valve duckbill for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump connecting nut with adapter suitable for existing dosing pump complete all as specified and directed by EIC . Make of connecting nut with adapter :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new connecting nut with adapter as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of connecting nut with adapter for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
Supply only dosing pump ferrule suitable for existing dosing pump complete all as specified and directed by EIC . Make of ferrule :- Declibac / Ramco or equivalent as approved by GE Note :- (i) Contractor shall bring the new ferrule as per existing model and make ,size for replacement of u/s.. (ii) Before procurement of ferrule for existing dosing pump contractor shall check the suitibility of model and make ,size of new to match with existing u/s.
M&L for disconnecting Submersible motor pump set of any capacity from electric system and lifting the pump and motor alongwith column pipe supporting wire , rope etc completely and lowering the whole system including addition of MS flanged pipe if required and connecting the electrical cable to starter after rectification of defects , repair / replacement of UNSV spare parts including testing complete all as specified and directed by Engr-In-Charge. Note :- 1. Necessary lathe work will be carried out by contractor and the amount will be deemed to be included in the unit quoted rate ( No extra payment will be given to contractor ) Change of motor and pump spare parts and windings shall be measured separately under relevant item. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit.
M & L for disconnecting Centrifugal motor pump set of any capacity from electric system , starter panel , lifting from foundation and carrying to workshop for repair and replacement of spare parts , reinstall in existing location or new location after repairing including reconnection testing etc and spray painting of motor pump set with two coat of synthetic enamel paint over one coat of redoxide primer and complete all as specified and directed by Engr-In-Charge. Note :- 1. Necessary lathe work will be carried out by contractor and the amount will be deemed to be included in the unit quoted rate ( No extra payment will be given to contractor ) Change of motor and pump spare parts and windings shall be measured separately under relevant item. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit.
M&L for motor winding of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Rotor of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bushing of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of thrust bearing of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Impellers of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of diffuser of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bush GM of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bush ruller of submersible motor of capacity 7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for motor winding of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Rotor of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bushing of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of thrust bearing of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Impellers of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of diffuser of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bush GM of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bush ruller of submersible motor of capacity 15 HP complete all as specified and directed by Engr-In-Charge.
M&L for motor winding of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Rotor of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bushing of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of thrust bearing of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Impellers of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of diffuser of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bush GM of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of bush ruller of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of neck ring of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of stud nut of submersible motor of capacity 20 HP complete all as specified and directed by Engr-In-Charge.
M&L for windings of centrifugal motor of capacity 5/7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Rotor of centrifugal motor of capacity 5/7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of sleeves and core packing of centrifugal pump of capacity 5/7.5 HP complete all as specified and directed by Engr-In-Charge.
M&L for replacement of Impellers of centrifugal pump of capacity 5/7.5 HP complete all as specified and directed by Engr-In-Charge.
Supply only steel wire rope (SWR) 10 mm dia all as specified by EIC . Make : Usha Martin or equivalent make as approved by GE. Note :- Sample approved by Engr-In-charge before procurement of material.
Supply only submersible cable 6 sqmm 3 core flat cable copper conductor all as specified by EIC Make : Finolex/Havells or equivalent make as approved by GE.
Supply only rubber packing mat 6 mm thick heavy duty all as specified by EIC. Note :- Sample approved by Engr-In-charge before procurement of material.
Supply only hexagonal head MS nuts bolts and washers of different required sizes as per sample provided by department or as per site requirement as directed by Engr-In-Charge. Note :- Sample approved by Engr-In-charge before procurement of material.
Supply only U clamp heavy duty for steel wire rope clamping all as specified by EIC. Note :- Sample approved by Engr-In-charge before procurement of material.
Material and labour for cleaning and washing of inside portion of RCC overhead reservoir round/square type of capacity 1.10 lakhs gallons height upto 25 m including removing of sand /mud and fungus formation etc with wire mesh brush, bleaching powder and deposited to 50 mtr away from the O/T and white wash the total inside the tank and write cleaning date and due date. All as specified and directed by Engr-in-charge. Note :- Following work amount will be deemed to be included in the unit quoted rate ( No extra payment will be given to contractor ) 1. Drain out the water by using exit valve or own high capacity dewatering system. 2. Fresh water cleaning by high pressure jet pump. 3. Cleaning the floor of the water tank by industrial vaccum cleaner.
All as per item no 47 here-in-before but for capacity of 60000.00 gallons complete all as specified and directed.
All as per item no 47 here-in-before but for under ground sump capacity of 10000.00 gallons complete all as specified and directed.
Taking down old u/s starters of any capacity and size from existing panel/wall and making good surface (in wall) complete all as specified and as directed by Engineer-in- charge.
Supply & Fix fully automatic star delta Submersible pump starter in sheet steel enclouser suitable for 20 HP pump set , 3 phase , 415 volt , 50 Hz , with maximum overload relay range 24-39 Amp , contactor rating 40 Amp having overload , single phasing , phase reversal , phase imbalance ,dry run and short circuit protection , Ammeter meter and voltmeter , On/Off and trip indication including making all electrical connection to run the pump all as specified and directed by Engr-In-Charge. Make:- BCH / L&T / C&S
Supply & Fix fully automatic star delta Submersible pump starter in sheet steel enclouser suitable for 15 HP pump set , 3 phase , 415 volt , 50 Hz , with maximum overload relay range 17-24 Amp , contactor rating 25 Amp having overload , single phasing , phase reversal , phase imbalance ,dry run and short circuit protection , Ammeter meter and voltmeter , On/Off and trip indication including making all electrical connection to run the pump all as specified and directed by Engr-In-Charge. Make:- BCH / L&T / C&S
Supply & Fix DOL pump starter in sheet steel enclouser suitable for 7.5 HP pump set , 3 phase , 415 volt , 50 Hz , with maximum overload relay range 13-20 Amp , contactor rating 16 Amp having overload , single phasing , phase reversal , phase imbalance ,dry run and short circuit protection , Ammeter meter and voltmeter , On/Off and trip indication including making all electrical connection to run the pump all as specified and directed by Engr-In-Charge. Make:- BCH / L&T / C&S
Supply & Fix DOL pump starter in sheet steel enclouser suitable for 3 HP pump set , 1 phase , 220 volt , 50 Hz , with maximum overload relay range 13-22 Amp , contactor rating 16 Amp having overload , including making all electrical connection to run the pump all as specified and directed by Engr-In-Charge. Make:- BCH / L&T / C&S
M&L for Flushing of tube well bore with compressed air by using air compressor for pumping muddy water continuously 8 Hrs without break complete as directed by Engr-in-Charge. Note:- Compressor of CFM with minimum 10 Kg/ cm² pressure to be used for flushing.
Taking out old u/s any type column pipe and supply & fix MS column pipe 100 mm dia bore , 10 feet long each with flanges screwed and welded both ends complete with nuts , bolts , gasket etc for jointing pipe and lowering into bore well complete all as specified and directed by Engr-In-charge. (Note:- The pipe shall be heavy duty not less than 6 mm thickness of wall conforming to IS-1239 Part-I of 1979/3589 of 1981 and the flanges shall have grooves to accommodate the submersible cable and sling wires.)
Taking out old u/s GI pipe of 50 mm dia as column pipe of bore well and Supply and fixing GI column pipe 50 mm dia bore heavy class ,cut 10 feet long with long thread at both side including supply of heavy duty sockets on both end for jointing the pipes and lowering into bore well complete all as specified and directed by Engr-In-charge.
Supply only Alum Gel suitable for disinfection, algae control, and coagulation of swimming pool water as approved by Garrison Engineer.
Supply only Chlorine liquid as per IS 11673 grade-II ( 10-12% free chlorine) Sodium Hypochlorite solution for disinfection, algae control, and coagulation of swimming pool water packed in container . Make- PSI or as approved by Garrison Engineer.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth in any type of soil and getting out for taking up/laying of GI/PPR/CI pipes all as specified and directed .
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as directed
Removal of surplus soil to a distance n.exc 50 mtrs and deposited where directed at a level n.exc1.5 mtr above the starting point.
Material and labour for road cutting of WBM/PCC path/road and passing the pipe line below and making the disturbed surface as per existing pattern all as directed and specified.
Taking out old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc including all fittings of 50mm bore complete all as specified and directed by Engr-in charge. Note: Excavation/earth work will be measured and paidseparately under relevent item.
All as per item No 66 above herein before but of size 40 mm bore.
All as per item No 66 above herein before but of size 25 mm bore.
All as per item No 66 above herein before but of size 20 mm bore.
All as per item No 66 above herein before but of size 15 mm bore.
Material and labour for laying of GI tube medium grade 50 mm bore ISI marked, with all fittings as required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note Union or long screw have to provided by contractor at tapping point/ at the place where old and new pipe line connected/inserted as required at site and directed by Engineer in Charge.
All as per item No 71 above herein before but of size 40 mm bore.
All as per item No 71 above herein before but of size 25 mm bore.
All as per item No 71 above herein before but of size 20 mm bore.
All as per item No 71 above herein before but of size 15 mm bore.
Material and labour for fixing of GI tube medium grade 50 mm bore with all fittings as required at site and fixed to walls and ceiling or laid in floor incl connecting with existing lines all as directed by Engr in charge. Note Union or long screw have to provided by contractor at tapping point / at the place where old and new pipe line connected/inserted as required at site and directed by Engineer in Charge.
All as per item No 76 above herein before but of size 40 mm bore.
All as per item No 76 above herein before but of size 25 mm bore.
All as per item No 76 above herein before but of size 20 mm bore.
All as per item No 76 above herein before but of size 15 mm bore.
Material and labour for fixing GM globe/gate valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS , heavy class including taking down old u/s complete all as specified and directed by Engr in charge. Note: Union or long screw have to provided before fixing of gate valve. Make: Zoloto/ Leader/
All as per item No 81 above but of size 40 mm bore.
All as per item No 81 above but of size 25 mm bore.
All as per item No 81 above but of size 20 mm bore.
All as per item No 81 above but of size 15 mm bore.
Material and labour for run lead joints for connecting of the CI pipes 300 mm dia complete all as specified and directed.
Material and labour for run lead joints for connecting of the CI pipes 250 mm dia complete all as specified and directed.
Material and labour for run lead joints for connecting of the CI pipes 200 mm dia complete all as specified and directed.
Material and labour for run lead joints for connecting of the CI pipes 150 mm dia complete all as specified and directed.
Material and labour for run lead joints for connecting of the CI pipes 100 mm dia complete all as specified and directed.
Material and labour for run lead joints for connecting of the CI pipes 80 mm dia complete all as specified and directed.
Taking out old unserviceable cast iron pipe of any dia bore including all fittings with spigot and socket ends and burning out lead joints complete all as specified and directed by Engr- in charge. Note : Excavation /earth work will be executed and measured separately under relevant item.
Supply and laying of Cast iron pipe (CI) with spigot and socket end suitable for and including tighten joint gasket of dia 200 mm size centrifugally cast class "B" in any length laid in trenches. Note :- Excavation and earth work will be measured and paid separately under relevant item of sch A. .
Supply and laying of Cast iron pipe (CI) with spigot and socket end suitable for and including tighten joint gasket of dia 100 mm size centrifugally cast class "B" in any length laid in trenches. Note :- Excavation and earth work will be measured and paid separately under relevant item of sch A. .
Supply and laying of Cast iron pipe (CI) with spigot and socket end suitable for and including tighten joint gasket of dia 80 mm size centrifugally cast class "B" in any length laid in trenches. Note :- Excavation and earth work will be measured and paid separately under relevant item of sch A. .
Material and labour for fixing of CI special Spigot/ socketed /Flanged end (Bends any type, radius an angle Tapers any type,straight, bend, increasing, decreasing or double socket etc. Tee pieces single branch, `Y' junction, double branch, cross all sockets or socket and spigot collars, caps and plugs up to 150 mm bore all as per site requirement and as directed by EIC..
Material and labour for fixing of CI special Spigot/ socketed /Flanged end (Bends any type, radius an angle Tapers any type,straight, bend, increasing, decreasing or double socket etc. Tee pieces single branch, `Y' junction, double branch, cross all sockets or socket / spigot/ all Flanged and collars, caps and plugs of size from 200 mm to 300 mm bore as per site requirement and as directed by EIC..
Taking down unserviceable sluice valve/NRV/foot valve at sewage/ water supply pipe line / chamber and their fitments like gasket , bolt/nuts of size 80 to 300 mm bore without damaging the valve chamber and pipe line complete all as specified and directed by Engineer-In-charge
Supply and fixing CI sluice valve ISI marked , Conf to IS 14846 class PN 1.6 with brass spindle, gasket, bolts, nuts and washers in position of 200 mm bore with hand wheel in valve pit chambers on any water and sewage line or near to bore well all as specified and directed by Engr-in-charge.
Supply and fixing CI sluice valve, ISI marked , Conf to IS 14846 class PN 1.6 with brass spindle, gasket, bolts, nuts and washers in position of 150 mm bore with hand wheel in valve pit chambers or near to bore well all as specified and directed by Engr-in-charge.
Supply and fixing sluice valve ISI marked , Conf to IS 14846 class PN 1.6 with brass spindle, gasket bolts, nuts and washers in position of 100 mm bore with hand wheel in valve pit chambers bore in valve pit chambers on any water and sewage line or near to bore well all as specified and directed by Engr-in-charge.
Supply and fixing sluice valve ISI marked , Conf to IS 14846 class PN 1.6 with brass spindle, gasket bolts, nuts and washers in position of 80 mm bore with hand wheel in valve pit chambers bore in valve pit chambers on any water and sewage line or near to bore well all as specified and directed by Engr-in-charge.
Taking out old unserviceable of MS pipe of any dia bore including all fittings any type complete all as specified and directed by Engr- in charge.
S&F seamless MS pipe 100 mm dia bore for bore well column pipe, with flanged end (MS flanges screwed and welded on both ends), including joing and connecting by providing MS nuts, bolts, gasket etc. and lowering in bore well complete all as specified and directed by EIC. Note : (i) The pipe shall be heavy duty MS pipe not less than 6 mm thick of wall conforming to IS-1239 (Part - I) of 1979/3589: 2001. (ii) The flanges shall have 8 hole and grooves to accommodate the submersible cables and sling wires. Lath work required for drilling hole as per existing to be done by contractor without any extra cost. (iii) MS Flange thickness shall not be less than 8 mm. (iv) The length of pipe shall be of 3.0 mtr with MS flange screwed and welded at both the ends.
Supply only short piece MS pipe heavy duty, min thickness 6 mm, of min length 1.0 mtr, 100 mm dia having one end welded and screwed with MS flange having 4 or 8 hole and grove for passing of submersible cable and wire ropeand other side with thread end having 8 pitch complete all as directed and specified by EIC.
Supply only short piece MS pipe heavy duty, min thickness 6 mm, of min length 1.0 mtr, 100 mm dia having one end welded and screwed with MS flange having 4 or 8 hole and grove for passing of submersible cable and wire ropeand other side with thread end having 11 pitch complete all as directed and specified by EIC.
Supply only MS reducer socket of size 100 mm x 80 mm dia having internal thread on 100 mm side and external thread on 80 mm side. complete all as directed and specified by EIC.
Supply only MS reducer socket of size 100 mm x 50 mm dia having internal thread on 100 mm side and external thread on 50 mm side. complete all as directed and specified by EIC.
Supply only MS reducer socket of size 80 mm x 50 mm dia having internal thread on 80 mm side and external thread on 50 mm side. complete all as directed and specified by EIC.
Supply & fixing of Bib taps, PVC of size 15 mm dia, ISI marked, complete all as directed . Make: Prayag or equivalent make as approved by GE./
Supply only flexible coupling (Mechanical Joint) leakeproof of size 300 mm , ISI marked , long body all as specified by EIC . Make : RMCO or equivalent make as approved by GE. Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing flexible coupling (Mechanical Joint) leakeproof of size 200 mm , ISI marked , long body all as specified by EIC . Make : RMCO or equivalent make as approved by GE. Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing flexible coupling (Mechanical Joint) leakeproof of size 150 mm , ISI marked , long body all as specified by EIC . Make : RMCO or equivalent make as approved by GE. Note :- Note :- Contractor shall produce the sample before procurement of item..
Supply and fixing flexible coupling (Mechanical Joint) leakeproof of size 100 mm , ISI marked , long body all as specified by EIC . Make : RMCO or equivalent make as approved by GE. Note :- Note :- Contractor shall produce the sample before procurement of item.
Supply only flexible coupling (Mechanical Joint) leakeproof of size 80 mm , ISI marked , long body all as specified by EIC . Make : RMCO or equivalent make as approved by GE. Note :- Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing CI venturi conduit of 150 mm in existing or new location including making all connections jointing, connecting chlorine dossing pipe connection by providing all fittings as required at site including taking out old u/s complete all as specified and directed by Eng in Charge. Make : RMCO or equivalent make as approved by GE. Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing CI angular type diaphargm valve of 100 mm dia in existing or new location including making all connections jointing by providing nut bolts, washers and rubber gasket including taking out old u/s complete all as specified and directed by Eng in Charge. Make : RMCO or equivalent make as approved by GE. Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing CI foot valve of 80 mm dia with Gun metal working part, Conf to IS 4038 in existing including making all connections jointing by providing nut bolts, washers and rubber gasket including taking out old u/s complete all as specified and directed by Eng in Charge. Make : RMCO or equivalent make as approved by GE. Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing CI foot valve of 50 mm dia with Gun metal working part, Conf to IS 4038 in existing including making all connections jointing by providing nut bolts, washers and rubber gasket including taking out old u/s complete all as specified and directed by Eng in Charge. Make : RMCO or equivalent make as approved by GE. Note :- Contractor shall produce the sample before procurement of item.
Supply and fixing 40 mm dia HDPE pressure pipe for water supply installation heavy duty ,confirming to relevant IS having pressure rating PN 10 complete all as directed by EIC.
S&F in repair high tensile brass splindle with GM check nut of 300 mm dia , PN 1.6 to match with the existing including removing sluice valve top from body and refixing by providing new nut bolts, washers and rubber sheets including taking out old u/s complete all as specified and directed by EIC.
S&F in repair high tensile brass splindle with GM check nut of 200 mm dia , PN 1.6 to match with the existing including removing sluice valve top from body and refixing by providing new nut bolts, washers and rubber sheets including taking out old u/s complete all as specified and directed by EIC.
Supply only of rubber sheet of min 3 mm thickness for use in jointing sulice valves with flange etc as directed by EIC.
Taking out old u/s starter and S&F Fully automatic star delta Sewage pump stater in sheet steel enclosure suitable for 10 HP/7.5 KW pump set, 3 Phase, 415 V, 50 HZ, with maximum overload relay range 13-20 Amp, contactor rating 25 Amp having overload, single phasing, phase reversal, Phase imbalance and short circuit protection , Ammeter meter and volt meter, ON/OFF and trip indication including making all electrical connection to run the pump complete all as specified and directed by Eng in Charge. Make: BCH Model No. CPSDPALN or equivalent in L&T/ C&S.
T K Construction
CASTLE BUILDERS
Kalpana Traders
SG ENTERPRISE
Ganguly Construction
SUMAN CONSTRUCTION
Lotas Engineers
MS R.K.ENTERPRISE
M/S SINGH ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .