Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.4 L+₹2.4 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Reject being not Lowest bidder | |
| 3 | L3₹26.9 L+₹3.9 L (16.9%)Rejected-Finance | L3 | Rejected-Finance Reject being not Lowest bidder | |
| 4 | L4₹29.4 L+₹6.5 L (28.1%)Rejected-Finance | L4 | Rejected-Finance Reject being not Lowest bidder | |
| 5 | L5₹31.5 L+₹8.5 L (36.9%)Rejected-Finance | L5 | Rejected-Finance Reject being not Lowest bidder |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
24 Sept 2020, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/REPLACEMENT OF LIGHT FITTINGS, CABLE JOINTS, SWITCH GEAR WITH OTHER CONNECTED WORK AT CH(CC), CMDC, ECHS, SHO, OFFICER MESS, SINGLE JCO/OR ACCN IN THE AREA OF AGE EM (HOSP) UNDER GE E/M LUCKNOW
2020_MES_371163_1
GE/EM/LKO/HOSP/T-41 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b(i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹86,000
Yes
29 Oct 2020
21 Aug 2020
26 Sept 2020
21 Aug 2020
24 Sept 2020
8 Sept 2020
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed by Engineer-in-Charge.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed by Engineer-in-Charge.
S & F GI tubing 'Light' grade 40 MM for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes complete all as specified and directed by Engineer-in-Charge.
All as per item No 7 above but size 50 mm bore dia
Labour for taking out the unserviceable / faulty cable after meggering , finding the fault , cutting the cable , jointing with jointing kit using extra cable if required ,relaying of cables upto 150 sqmm 3.5 core ,connecting, rate included of excavation works, using old bricks complete all as specified and directed by Engineer-in-Charge. Note :, cable joints will be measured and paid seperatly under respectrive item of schedule.
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed by Engineer-in-Charge. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 10 above but of size 10 Sqmm 4 core
All as per item No 10 above but of size 16 Sqmm 4 core
All as per item No 10 above but of size 25 Sqmm 3.5 core
All as per item No 10 above but of size 50 Sqmm 3.5 core
All as per item No 10 above but of size 95 Sqmm 3.5 core
All as per item No 10 above but of size150 Sqmm 3.5 core
All as per item No 10 above but of size185 Sqmm 3.5 core
Straight through joints (Heat Shrink Kits) for LT underground cable indoor/outdoor type complete for Armoured ,PVC sheathed Aluminium conductor cables by excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth for the 3.5 core cable 25 to 50 Sq mm sizes complete all as specified and directed by Engineer-in-Charge. (Make Denson or eqvlnt as per PS )
All as per item No 18 above but 70 to 150 Sq mm 3.5 core cable
All as per item No 18 above but 185 sqmm to 300 sqmm 3.5 core cable
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 25 to 100 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4200 10 to 15 or eqvlnt as per PS
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4200 56 or eqvlnt as per PS
MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4200 57 or eqvlnt as per PS
MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 200 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4202 48 or eqvlnt as per PS
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4202 49 or eqvlnt as per PS
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4202 49 or eqvlnt as per PS
Power contactor 4 pole Type Mcx 32 , Fr size 2 rating AC 1 rating 160 A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed by Engineer-in-Charge.
Power contactor 4 pole Type Mcx 23 , Fr size 1 rating AC 1 rating 40A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed by Engineer-in-Charge.
Digital type Volt meter , 3 ph , class 1 including taking down unserviceable voltmeter, complete all as specified and directed by Engineer-in-Charge.
Digital type Ammeter 3 ph , 5 Amps , class 1 including taking down unserviceable ammeter, complete all as specified and directed by Engineer-in-Charge.
Indicator lamps (LED Type) including taking down unserviceable indicator lamps complete all as specified and directed by Engineer-in-Charge.
S & F in rep MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with 'B" ‘C’ curve, fixed in existing PVC box including connecting complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of old painted surface of steel tubular pole (9/11/12) meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specified and directed by Engineer-in-Charge.
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and directed by Engineer-in-Charge.
Dismantling the existing unserviceable ( damaged/broken) LT street light swaged poles / RCC poles or unserviceable tilted steel pole of any size, from ground after necessary excavation etc. and removing the unserviceable poles including making good disturbed ground and deposite in MES store yard complete all as specified and directed by Engineer-in-Charge.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed by Engineer-in-Charge.
Restreching only existing LT OH/ HT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire 2/4/5/6 Lines of ACSR and 1 line of GI wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Linear length centre to centre of the poles shall only be measured (ii) Cleaning / pruning of tree branches falling around the conductor shall also deemed to be included in the quoted rates
S & F Off load change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed by Engineer-in-Charge. Make havells cat part no . IHBFFE0200 or eqvlnt make as per PS
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed by Engineer-in-Charge. Make havells cat part no. IHBFFE0063
S & F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and directed by Engineer-in-Charge. Make havells cat part no IHBFFE0400.
Supply fixing testing and commissioning of ( in rep) LT ACB 4 pole of capacity 1250 Amps 50Ka Manual Fixed (MF) Microprocessor Release, Auxiliary Switch 5a 5b5NO+5NC, Main CTs, Terminal Type - Horizontal,upto 2500A & Vertical for 3200A~6300A, Rectifier (24V DC supply) complete all as specified and directed by Engineer-in-Charge. Make C&S cat part no AHA12N4P*MP3.1(S). Note- Old UNSV ACB to be deposited in MES store yard
S & F street light panel single phase up to 6 kw load with Astronomical digital timer and MCB of capacity 40 / TP and SPN 32 Amps fixed on wall/pole with clamps,nut bolts complete all as specified and directed by Engineer-in-Charge. Make havells Cat part no. IHXSS0106A or eqvlcnt make as per PS
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 630 AMPS complete all as specified and directed by Engineer-in-Charge. Legrands cat part no. 4222 57 or eqvlnt as per PS
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed by Engineer-in-Charge. and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L Earthing complete with Copper earth Plate electrode 60x60cmx3.15mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, Including connected to copper strip 20x3mm lead (upto 7.5 Mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion.ith salt to a packed thickness of 15 cm all around the plate, and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed by Engineer-in-Charge. and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Dismantling and removing existing unsv street light/ flood light MH/HPSV fittings of any type and any capacity from street light poles any hieght and high mast light pole after disconnecteing of electrical connection complete all as specified and directed by Engineer-in-Charge.
Supply,Fixing,Connecting and testing energy saving LED Street Light Fittings 35 Watt with thermal management, potted driver, pressure die cast housing LM6 alloy/anti dust exposed lems,in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed by Engineer-in-Charge. Make: Havells cat part no: Enduracity Light Plate Plus SSl 35WLRD757SASYBPOC//Philips cat Part No. BRP409LEDCW035 NR FG S1 PS GR or EQVLNT MAKE as per PS.
Supply, fixing, connecting and testing energy saving LED street light fittings 45 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part no enduracity linerneos 100 WLED757SASYBOPC/cROPMTON GREAVE CAT PART NO.LSTS-45-CDL-1 OR EQVLNT MAKE AS PER PS
Supply, fixing, connecting and testing energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat Part No. LSTP-60-CDL//Philips Cat Part No. BRP409 LED 060 CW HE NR PC S1 PSU GR OR EQVLNT MAKE AS PER PS
Supply, fixing, connecting and testing energy saving LED street light fittings of 100 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part no enduracity linerneos 100 EW LED 75 7SASBTOYG / PHILIPS CAT PART NO BRP410LED100CWHENRPCS2PSUGR OR RQVNT MAKE AS PER PS
Supply, fixing, connecting and testing energy saving LED street light fittings of 90 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat Part No. LSTN90-CDL-A/Havells Cat Part No. ENDURACITYLINERNEOSL90WLED757SASYBOTG
S&F in replacement GI bracket for street light fittings fabricated with GI tubing 40mm dia 'light grade' 1.5m long and bending to angle of 120 degree including mild steel clamp of suitable size with two coat aluminium paint suitable for fixing on PCC/steel poles complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 120 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed by Engineer-in-Charge. Make :- Havells Cat Part no. JETPROPLUSFL120WLED757LTG/ /CRPMPTON FREAVES CAT PART NO . LFLN-120-CDL/60 OR EQVLNT MAKE AS PER PS
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 150 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed by Engineer-in-Charge. Make :- Havells Cat Part no. JETPROPLUSFL150WLED757LTG/ PHILIPS CAT APRT NO BVP122 LED 150 CW HE SY 20 DEGREEE FG XTFCL S4 OR EQVLNT MAKE AS PER PS
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 145 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed by Engineer-in-Charge. Make philips CAt part No. BY415P LED 145 S CW HE WB FG PSU GR XT FCL S5/CG CAT PART NO. LFLN-150-CDL/60 OR OTHER EQVLCNT MAKE AS PER PS
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 160 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed by Engineer-in-Charge. Make philips CAt part No . BY415P LED 160 S CW HE NB FG PSU GR XTFCL S5/CG CAT APRT NO. LSFO-170-CDL/60 OR EQVLNT MAKE AS PER PS
Supply, fixing, connecting and testing energy efficient LED blolard light of 18 Watt including foundation work with PCC as required complete all as specified and directed by Engineer-in-Charge. Make philips CAt part No .BCP150 LED150/WWPSU220-240V 7043
Supply, fixing, connecting and testing energy efficient LED POST TOP LANTERN WITH SYMMETRIC LIGHT DISTRIBITION AND LIMITED UPWARD LIGHT COMPONENT light of 18 Watt in replacement complete all as specified and directed by Engineer-in-Charge. Make philips CAt part No .BGP161 LED2500/NW PSU 220-240 V 7043 IN
Shree Tirupati Associates
M K Engineers and Contractors
m/s pal associates
Ajanta Associates
PUMA POWER
SRI HARSHITA ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .