Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.1 LAccepted-AOC 261 NAPIER TOWN DR BARAT ROAD JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹82.5 L+₹12.3 L (17.6%)Rejected-Finance A 3 257 2ND FLOOR JANAKPURI ASALATPUR ROAD JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0007281 | WEST DELHI | DELHI | 110058 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹83.0 L+₹12.8 L (18.3%)Rejected-Finance GITANJALI SQUARE HOTEL PAL PALACE ROAD C A LODHIPURA ZANDA CHOWK NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹84.6 L+₹14.5 L (20.7%)Rejected-Finance 106 AGARWAL AND COMPANY PROFESSOR COLONY OPP OF WALL FORT CITY RING ROAD NO 01 RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹90.2 L+₹20.0 L (28.6%)Rejected-Finance 121 GURU GOVIND SINGH MARG LAL KUAN LUCKNOW UTTAR PRADESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
3 Nov 2022, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
SPECIAL REPAIR OF FURNITURE AGAINST SURVEYED OFF VIDE EXPENSE VOUCHER NOS. 24, 25 AND 26 UNDER GE(WEST) JABALPUR (SCH A PART-II STEEL FURNITURE)
2022_MES_554398_1
81945/S/E8
Open Tender
Civil Works
Item Rate
120 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE WEST JABALPUR
₹1.4 L
Yes
29 Dec 2022
26 Sept 2022
5 Nov 2022
26 Sept 2022
3 Nov 2022
22 Oct 2022
26 Sept 2022 - 15 Oct 2022
Amount
Almirah Large Steel with shelves Drg No.FD-1031 Sheet 1/1 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Almirah Large Steel 1/2 Hanging and 1/2 Shelving Drg No.FD-1033 Sheet 1/1 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Almirah small Steel Drg No. FD-1032 Sheet 1/1 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Almirah Small Steel 1/2 Hanging and 1/2 Shelving Drg No.FD-1034 Sheet 1/1 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Bed Hard Drg No.FD/ E6/ MAP/ 08(R) Sheet 1/1 dt 06 Mar 2007 revised upto 19 Mar 2007 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Lockers Steel Drg No.SKD-562 Sheet 1/1 dt 19 Jun 1998 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Book case steel Drg No.FD-1028 Sheet 1/1 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Charpoy with Hard Top Drg No.FD/ Map-II/ 01 Sheet 1/1 dt 08 July 2011 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Chair Writing Drg No.FD/ E6/ Map/ 12 Sheet 1/1 dt 18 Oct 2006 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Chair Visitor TP (Make : Methodex, Model V-31 or equivalent Model of Godrej/Durian as approved by GE) Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Chair Verandah with NYLON NEWAR Drg No.FD-256 Sheet 1/1 dt 21 Jul 1981 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Shoe Rack Drg No.FD/ E6/Map/02(R) Sheet 1/1 dt 16 Oct 2006 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Table with Drawer (Steel) Drg No.FD-1008 Sheet 1/2 & 2/2 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Table without Drawer (Steel) Drg No.FD-1007 Sheet 1/2 & 2/2 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Table (Steel)(900x900x760) Drg No.FD-1009 Sheet 1/2 & 2/2 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Table for Senior Officers (Steel) Drg No.FD-1002 Sheet 1/2 & 2/2 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Ladder Aluminium Drg No.FD-1025 Sheet 1/2 & 2/2 dt 29 Sep 1993 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Pad Lock 65 mm six lever with duplicate Key TP Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Receptacle Drg No.FD/ E6/ MAP/ 13 Sheet 1/1 dt 18 Oct 2006 Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Executive Table TP (Make: Methodex, Model Riva 1800 with Mobile Pedestral Riva M21 +Riva F21 or Equivalent Model of Godrej/Durian as approved by GE)) Note:- Key Specifications shall be read in conjunction with Drawings where at variance, the Key Specifications shall take precedence over those given in the Drawings.
Capital Construction Company
Apsara Industries
agarwal and company
JAISWAL ENTERPRISES
swastik industries
Nav Bharat Timber Traders
SKYLIGHT INNOVATIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .