Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAdmitted-Finance | ₹10.5 L | L1 | Admitted-Finance |
| 2 | L2₹10.5 LAdmitted-Finance GHAZIABAD 201206 U P INDIA MURADNAGAR GHAZIABAD UTTAR PRADESH 201206 UDYAM UP 29 0018296 09ATCPK8932G1ZH R M | GHAZIABAD | UTTAR PRADESH | 201206 | ₹10.5 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AGNI AUTOMATION AND SECURITY L2 | K.L Enterprises L1 |
|---|---|---|---|---|---|
| 1.01 | Work of Opening/Disconnection of the main incoming LT power supply from the LT panel , racking out the breaker to ensure the power is disconnected from all sources connected to FCMA Soft Starter Panels & arrangement of safety helmet etc to start the work. | 1 | Job | 7,450 ₹8,791 | 7,450 ₹8,791 |
| 1.02 | Rectification of wiring of the control circuit of the Starter Panel & tightness of all connections. | 3 | Job | 55,290 ₹65,242.20 | 55,350 ₹65,313 |
| 1.03 | Rectification of wiring of the Power circuit of the Starter Panel & tightness of all connections. | 3 | Job | 1,27,305 ₹1.5 L | 1,27,200 ₹1.5 L |
| 1.04 | Supply and installation of main By Pass contactor of MNX 185 (250 Amp AC1) 240 V AC with 2 NO + 2 NC work includes the dismantling of old contactor along with opening of incoming & outgoing connection of cable/busbar and opening the connection of Aux Block and tripping etc. | 3 | Job | 1,30,500 ₹1.5 L | 1,27,200 ₹1.5 L |
| 1.05 | Servicing of main contactor in each panel , Checking and tightening of the contacts and contact assembly for any pitting, hot spots or any abnormal conditions and replacing damaged contacts with new spares ,Cleaning the operation mechanism including spring mechanism, Checking and tightening of all busbars of switchgear CTs, terminal blocks and checking for any hotspots , Checking of total earth continuity for non conducting items of the switchgear panel work includes cleaning of the terminal and coil and incoming & outgoing connections fixed with high tensile nut and bolts fixed and associated wiring of the auxiliary blocks. | 3 | Job | 74,580 ₹88,004.40 | 74,850 ₹88,323 |
| 1.06 | Manual functional testing of the Panel along by directly giving command from the terminal blocks with all required tools, manpower etc. | 3 | Job | 37,530 ₹44,285.40 | 37,500 ₹44,250 |
| 1.07 | Work of checking the current at Starting time and adjustment as per site requirement & as required by FCMA starter along with all required tools. | 3 | Job | 1,19,610 ₹1.4 L | 1,19,700 ₹1.4 L |
| 1.08 | Work of replacement of all the timers and Aux contactors connected in the control circuit & ensuring the working of each and every components In the panel. | 3 | Job | 1,09,350 ₹1.3 L | 1,09,200 ₹1.3 L |
| 1.09 | Assembling the panel after completion of the work & closing and mounting of all components. Cleaning of the Panel with Vacuum cleaner/blower ensuring that no control and power wiring is disturbed during the work. | 3 | Job | 74,760 ₹88,216.80 | 74,850 ₹88,323 |
| 1.10 | Tunning of FCMA unit for its proper performance & functioning as per manufacturer's published data, work includes the adjustment in taps /connections as per motor specification and full load current. | 3 | Job | 75,240 ₹88,783.20 | 75,000 ₹88,500 |
Tender Value
Refer Docs
EMD Value
₹20,900
Closing Date
19 Feb 2026, 11:15 amClosed
EE ENM M VII
MU BLOCK PITAMPURA DELHI-34
Repair Renovation of innovative make soft starters installed at Kirti Nagar BPS
2026_DJB_286766_9
NIT No. 33(2025-26)M-VII
Open Tender
Marine Works
90 days
EE ENM M VII
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹20,900
Yes
28 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
19 Feb 2026
12 Feb 2026
Work of Opening/Disconnection of the main incoming LT power supply from the LT panel , racking out the breaker to ensure the power is disconnected from all sources connected to FCMA Soft Starter Panels & arrangement of safety helmet etc to start the work.
Rectification of wiring of the control circuit of the Starter Panel & tightness of all connections.
Rectification of wiring of the Power circuit of the Starter Panel & tightness of all connections.
Supply and installation of main By Pass contactor of MNX 185 (250 Amp AC1) 240 V AC with 2 NO + 2 NC work includes the dismantling of old contactor along with opening of incoming & outgoing connection of cable/busbar and opening the connection of Aux Block and tripping etc.
Servicing of main contactor in each panel , Checking and tightening of the contacts and contact assembly for any pitting, hot spots or any abnormal conditions and replacing damaged contacts with new spares ,Cleaning the operation mechanism including spring mechanism, Checking and tightening of all busbars of switchgear CTs, terminal blocks and checking for any hotspots , Checking of total earth continuity for non conducting items of the switchgear panel work includes cleaning of the terminal and coil and incoming & outgoing connections fixed with high tensile nut and bolts fixed and associated wiring of the auxiliary blocks.
Manual functional testing of the Panel along by directly giving command from the terminal blocks with all required tools, manpower etc.
Work of checking the current at Starting time and adjustment as per site requirement & as required by FCMA starter along with all required tools.
Work of replacement of all the timers and Aux contactors connected in the control circuit & ensuring the working of each and every components In the panel.
Assembling the panel after completion of the work & closing and mounting of all components. Cleaning of the Panel with Vacuum cleaner/blower ensuring that no control and power wiring is disturbed during the work.
Tunning of FCMA unit for its proper performance & functioning as per manufacturer's published data, work includes the adjustment in taps /connections as per motor specification and full load current.
Complete testing of the panel after completion of the work using magger & testing of insulation of the all three phase with respect to earth by performing an insulation-resistance test at from pole-to-pole and from each pole-to-ground with breaker closed and across open contacts of each phase. Testing resistance measurements through all bolted connections with a low-resistance ohmmeter, confirming appropriate equipment grounding. Performing open and close operation in control mode, & testing of protection diode of the coil of vacuum contactor performing overpotential test in accordance with manufacturer's published data.
Old scrap rebate (-)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_379764.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid