| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC CHANDURIA SIMURALI DIST NADIA PIN 741248 | NADIA | WEST BENGAL | 741248 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.0 L+₹2.5 L (18.3%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-Finance L2 | |
| 3 | L3₹16.0 L+₹2.5 L (18.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 55 A KONCHATI POST TRIBENI DIST HOOGHLY PIN 712503 | TRIBENI | HOOGHLY | WEST BENGAL | 712503 | - | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹31,996
Closing Date
29 Mar 2023, 3:00 pmClosed
MD,WBMSCL
Swasthya Sathi, GN-29, Sector-V, Salt Lake, Kolkata 700 091.
Re-insulation and lagcoating of existing chiller water pipeline by removing the damaged insulation at Islampur Super Speciality Hospital.
2023_WBMSC_478955_1
WBMSCL/NIT- 83/2023 Dated 21/02/2023
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
ISLAMPUR SSH
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹31,996
26 Apr 2023
22 Feb 2023
30 Mar 2023
22 Feb 2023
29 Mar 2023
22 Feb 2023
Amount
Dismantling of existing insulating materials of the Chiller water pipeline and storing the waste insulating materials in a suitable place inside hospital premises for disposal.
25 mm dia Chiller water pipeline
38 mm dia Chiller water pipeline
50 mm dia Chiller water pipeline
63 mm dia Chiller water pipeline
100 mm dia Chiller water pipeline
125 mm dia Chiller water pipeline
150 mm dia Chiller water pipeline
The carring cost to dispose the waste insulating materials from the hospital premises to the Municipal garbage area.
Scrubbing the existing Chiller water pipelines with MRE Paper & cleaning the same for re-insulation.
25 mm dia Chiller water pipeline
38 mm dia Chiller water pipeline
50 mm dia Chiller water pipeline
63 mm dia Chiller water pipeline
100 mm dia Chiller water pipeline
125 mm dia Chiller water pipeline
150 mm dia Chiller water pipeline
Rectification of existing iron clamp as per site requirement with necessary angle iron & arc welding including necessary cutting wall/brick with mending the same.
Supply & Fixing of a closed cell black nitrile rubber (Class-1) with adhesive in existing Chiller water pipelines including Taping the whole with a 3mm thick Nitrile Adhesive Tape. (Make of nitrile rubber: K-flex, Make of Adhessive: Fevicol- Pedilite / Polygrip)
25 mm dia Chiller water pipeline with single layer 19mm nitrile rubber
38 mm dia Chiller water pipeline with single layer 19mm nitrile rubber
50 mm dia Chiller water pipeline with single layer 19mm nitrile rubber
63 mm dia Chiller water pipeline with single layer 25mm nitrile rubber
100 mm dia Chiller water pipeline with single layer 25mm nitrile rubber
125 mm dia Chiller water pipeline with double layer 19mm nitrile rubber
150 mm dia Chiller water pipeline with double layer 19mm nitrile rubber
The existing tapped chiller water pipeline would be covered with a markin cotton cloth and waterproof the same with two coat of weather proof Lag-Coating. (Make of Lag Coating: Fevicol Pedilite)
25 mm dia Chiller water pipeline
38 mm dia Chiller water pipeline
50 mm dia Chiller water pipeline
63 mm dia Chiller water pipeline
100 mm dia Chiller water pipeline
125 mm dia Chiller water pipeline
150 mm dia Chiller water pipeline
MILLENNIUM AIRCON
NEW ENVIRONMENT CONTROL CO.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .