Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.9 L+₹1.8 L (7.12%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹27.7 L+₹2.6 L (10.3%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹28.1 L+₹2.9 L (11.6%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹28.3 L+₹3.1 L (12.5%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹29.1 L
EMD Value
₹58,200
Closing Date
2 Mar 2023, 6:00 pmClosed
GE AF Kalaikunda
GE AF Kalaikunda
SPECIAL REPAIRS TO CERTAIN MARRIED ACCOMMODATION AT AIR FORCE STATION SALUA UNDER GE (AF) KALAIKUNDA
2023_MES_577626_1
C/8815/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Kalaikunda
as per NIT
7 documents required · 7 mandatory
₹500
GE AF Kalaikunda
₹58,200
Yes
15 Mar 2023
8 Feb 2023
3 Mar 2023
8 Feb 2023
2 Mar 2023
23 Feb 2023
Amount
Demolation of cement concret(reinforced) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing of debris from premises complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
Supply only integral water proofing compound all as specified
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete 25 mm thick type B-0, 1:2:4 (12.5 mm graded aggregate) as in base of flooring, finished even and rough to receive the top layers all complete as specified and as directed
Materials and Labour for for 40 mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate as in floor/paving/hardstanding complete all as specified and directed.
Materials and Labour for 75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded aggregates as in plinth protection /floor/paving/hardstandingincluding finishing surface even and smooth without using extra cement complete all as specified and directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 9 to 10mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in riser of steps, skirting, dado and pillar laid over cement screed base including 15 thick rendering Cement mortar (1:3) complete all as specified and directed
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic coloured tiles, 450 X 300 X 8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
M & L for 20 mm thick machine cut granite (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade including 20 mm thick screed in cement mortar 1:4 including grinding , polishing and rounding edges of slabs as required complete all as specified and as directed.
M & L for chequered cement concrete tiles chemically treated , cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 25 cm X 25 cm X 22 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
M & L for ceramic fully vitrified tiles, coloured ceramic floor tiles (group B Ia), 600 mm X 600 mm X 9-10 mm in floors laid over and including 15 mm thick screed bed or bedding layer in cement mortar(1:4) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed.
M & L for ceramic fully vitrified tiles, coloured ceramic floor tiles (group B Ia), 600 mm X 600 mm X 10 mm in skirting's/ vertical surfaces laid over and including 10 mm thick backing coat in cement mortar(1:3) set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
Preparation of newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off ceiling papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
Material and Labour for complete removal of existing treatment and applying two coats of cement-based paint, white or tinted over and including priming with alkali resistant priming paint to old plastered or unplastered surfaces on walls including preparation of surfaces, complete all as specified and directed.
M&L for complete removal of existing treatment from walls, and applying two coats acrylic distemper on walls,over and including a coat of 1 mm thick white wall care putty over and including a coat of primer old plastered or unplastered surfaces on walls plastered or unplastered surfaces on walls complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for complete removal of existing treatment from walls, and applying two coats acrylic distemper on walls,over and including a coat of 2 mm thick white wall care putty over and including a coat of primer old plastered or unplastered surfaces on walls plastered or unplastered surfaces on walls complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm Prelam PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
Supply and Fix, factory made solid panel Plain PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides plain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated.
M & L for 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
M&L for medium density fibre board 18mm , exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S & F 25mm bore PVC coated MS conduit drapery rods, suitable for door/widows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, brackets and fixed to wall complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed.
Supply and Fix, in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and with overall length of cover plate 150 mm, fixed in floor, complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including making good disturbed surfaces as per existing specfication complete all as specified and directed.
Supply and Fix, steel ventilator with top hung shutter including hinges, steel peg stay, complete without glazing bars, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed.
Supply and Fix,steel ventilator with fixed type shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, and provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling unserviceable tank complete all as specified and as directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1), by weight complete all as specified and as directed.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq. m, blinded with grit or pea size gravel @ 0.006 cu.m per sq.m, and lightly tampered (area of flashings, etc., shall be added to the roof area) (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding. (iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iv) Waterproofing treatment over smooth finished surfaces after application of cold applied bituminous primer @ 0.30 Kg /Sq M,, providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.50 Kg / Sq M, by torch on application method, with minimum 75 mm overlap on longitudinal direction and 100 mm overlap on the transverse direction or as per manufacturer,s instructions and finally applying with one coat of bituminous based solar reflective aluminium paint @ 100 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps complete all as specified and directed. (i) Complete removal of the existing water proofing treatment and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc and Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384. (iv) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. and finally applying with one coat of bituminous based solar reflective aluminium paint @ 100 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed Note: (i) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions. (ii) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (iii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd. 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Supplying & fixing to walls , ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply and Fix, in repair fancy bib tap, brass cast copper alloy, , chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
S&F in repairs 15 mm nominal size, Swan Neck Pillar Cock , cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish all as per catalogue No.T4668A1 of Make Parryware or equivalent of Make mentioned under PS complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed
S & F vitreous china squatting pan, 'Orissa" pattern, size min. 630 mm X 450 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings,brass pillar tap 15mm bore cp, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
Supply and Fix in repair, brass chromium plated, towel rail, 20mm dia, , 60cm long between flanges, complete all as specified and directed.Make Cat no.ACN-1111NM of Jaquar or equivalent of Marc/Kohler
Supply and Fix, brass CP fancy wall mixer with L bends (including provision of O/H shower & hand shower) for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed. (Make Hand shower cat part no. HSH-CHR-1717 and wall mixer cat part no. QQT-7281 of Jaquar or equivalent make Kohler/Marc)
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor (FRLSH) cable of 4.0 Sqmm as per IS 694: 2010, ISI marked (with colour code), drawn in but including PVC casing caping not less than 25 mm width, ISI marked, double locking type including one run of PVC insulated unsheathed, multistranded copper conductor (FRLSH) cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface complete all as specified and directed .
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor (FRLSH) cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH) cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (a) One light point controlled by one switch 5 Amps
(b) One fan point/Exhaust fan point controlled by one switch 5 Amps
(e) One bell point controlled by one bell push
(d) One 3 pin socket outlet 5 Amps on same board
(c) One 3 pin socket outlet 5 Amps on Independent board
Materials and Labour for concealed type point wiring with 4.00 Sq. mm (nominal area) (FRLSH) as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 4.00 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
Supply and fix ,bell push, flush type, single pole, 5 Amps, complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and Fix,switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix,switch socket combination 3 pin 5A/16A, 5 in 1 flush type, complete all as specified and directed.
S&F, bell electric, Ding Dong AC. 230 volts, single pole complete all as specified and directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d with M13 X 1 threaded entry complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with LED tube lamp nominal power 10 Watt, 2 feet ,LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1000Lumen efficacy of minimum 100 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120 degree clear, IHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per Make :- Century Cat No.BWUL010C OR equivalent of Syska LED/Philip/Wipro or equivalent make as per make catered in Particular specification complete all as specified and as directed. Note : Make of batten and LED tube lamp shall be same
S & F LED tube light fittings(T8 TYPE) with LED tube lamp nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 2100Lumen efficacy of minimum 110 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120 degree clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per Make :- Century (Batten Cat No.KCCF0200 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Century Cat No. TWPP020C (retrofit LED tube lamp 20 Watt, Single end connection) OR equivalent of Syska LED/Philip/Wipro or equivalent make as per make catered in Particular specification complete all as specified and as directed. Note : Make of batten and LED tube lamp shall be same make.
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No.LR02-391-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs including blanking plate , complete all as specified and directed. [Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/ Seimens]
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
SENCO
SUMAN CONSTRUCTION
M/s Tekcon International
Guru Charan Mahata
M/S OM BUILDERS
M/S Jamuna Traders
MS R.K.ENTERPRISE
Kalpana Traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .