GEMC-511687750573765
Awarded to Swastik electricals
₹1.2 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Microtek imax series online ups 3 kva 72v 7200 VAH | microtek imax series online ups 3 kva 72v 7200 VAH | - | 2 NOS | ₹59,700 | 119,400 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LQualified Make: microtek
Model: microtek imax series online ups 3 kva 72v 7200 VAH 46 BAHADUR MARG DEWAS DEWAS MADHYA PRADESH 455001 DEWAS MADHYA PRADESH 455001 | DEWAS | MADHYA PRADESH | 455001 | Make: microtek
Model: microtek imax series online ups 3 kva 72v 7200 VAH | L1 | Qualified | |
| 2 | L2₹1.6 L+₹36,386 (30.5%)Qualified Make: microtek
Model: microtek imax series online ups 3 kva 72v 7200 VAH 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: microtek
Model: microtek imax series online ups 3 kva 72v 7200 VAH | L2 | Qualified | |
| 3 | Disqualified Make: Eaton
Model: Eaton 3 KVA 9145 online UPS with 120 minutes backup | Make: Eaton
Model: Eaton 3 KVA 9145 online UPS with 120 minutes backup | - | Disqualified | |
| 4 | Disqualified Make: NUMERIC
Model: Numeric omnfiniti 3KVA online Ups 120 Min. Backup (VAH 7200) 2 Yr. Wty., without isolation transformer 5 JAMUNA GANGA JAMUNA APARTMENT NR HOTEL NEST OFF C G ROAD NAVRANGPURA AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Make: NUMERIC
Model: Numeric omnfiniti 3KVA online Ups 120 Min. Backup (VAH 7200) 2 Yr. Wty., without isolation transformer | - | Disqualified | |
| 5 | Disqualified Make: BPE
Model: BPE NIY 3KVA 7200VAH ONLINE UPS 2 YEARS AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIY 3KVA 7200VAH ONLINE UPS 2 YEARS | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Aug 2018, 5:00 pmClosed
Online UPS ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology IGBT-PWM without inbuilt isolation transformer IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15
30
60
90
120
180
240 Minimum VAH (VAH) 7200 7200 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without trollery but with rack With
Without
Without trollery but 1/4 with rack Warranty for battery 2 1
2 Degree of Protection IP21 IP21 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes * Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes * REPORTS AND Damp Heat : in Yes * 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 4465 * Type Test Certificate date 27-02-2017 * Name of Lab MICROTEK * Address of Lab ROHTAK ROAD DELHI * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Agusthia Minj 110016
Level-5
East Block-7
Sector 1
RK Puram
New Delhi - 110066 2 15
406725
GEM/2018/B/57557
GeM Contract
Online UPS
GeM Contract
15 days
Delhi; South Delhi
PRODUCT
Awarded to Swastik electricals
₹1.2 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Microtek imax series online ups 3 kva 72v 7200 VAH | microtek imax series online ups 3 kva 72v 7200 VAH | - | 2 NOS | ₹59,700 | 119,400 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology IGBT-PWM without inbuilt isolation transformer IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 7200 7200 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without trollery but with rack With | - | - | - |
| Without | - | - | - |
| Without trollery but 1/4 with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes * REPORTS AND Damp Heat : in Yes * 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 4465 * Type Test Certificate date 27-02-2017 * Name of Lab MICROTEK * Address of Lab ROHTAK ROAD DELHI * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Agusthia Minj 110016 | - | - | - |
| Level-5 | - | - | - |
| East Block-7 | - | - | - |
| Sector 1 | - | - | - |
| RK Puram | - | - | - |
| New Delhi - 110066 2 15 | - | - | - |
Exempted
2 Nov 2018
11 Oct 2018
contract_GEMC-511687750573765.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_406725.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .