Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.6 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹35.8 L+₹4.4 L (14.0%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹36.6 L+₹5.2 L (16.4%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹37.3 L+₹5.9 L (18.8%)Rejected-Finance | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹37.6 L+₹6.2 L (19.8%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | 5 | Rejected-Finance Not L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Sept 2022, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
REPAIR/MAINT OF VCB/RMU AND CONNECTED WORKS EAST OF MG ROAD UNDER GE E/M LUCKNOW
2022_MES_538064_2
CWE/LKO/EM/T-47 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹70,000
Yes
8 Oct 2022
13 Aug 2022
3 Sept 2022
13 Aug 2022
1 Sept 2022
20 Aug 2022
13 Aug 2022 - 20 Aug 2022
Amount
Periodical servicing to 11KV HT RMU (3/4/5/6 ways) any type complete including the following:- (a) Disconnecting the 11 KV line from RMU. (c) Opening the VCB/RMU and replacmenet the unserviceable part as required at site. (b) Checking of mechanical system for proper functioning of upward/downward or clock wise and anty clock wise movement of breaker. (d) Cleaning & servicing the fixed/ moving contact, busbar,cable boots with the CTC solution and greasing/oiling the parts where requied or as directed by manufacturer. (e) Tighting the all loos parts and testing complete as directed by EIC. (f) Setting the relay as directed by EIC. (g) Closed the all hole of VCB with ms jali and POP as directed by EIC (h) Repair the door/lock incl welding and painting and replacement of lock/handle
Note- (i) Replacing new items shall be measured and paid seperatly as a supply only. (ii) Other part which is not included but requierd for functioning of equipment is included in the quoated rate. (iii) Remove the moisture from VCB/RMU by heating/CTC solution every three months. (iv) If any defect occurred at any place of Lucknow cantt area, the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ whatsapp /email etc complete as specified and directed. (v) The above job to be carried out by engineer of authorised dealer/service centre of concerned OBC.(vi) Closed the all hole of VCB with ms jali and POP as directed by EIC (vii) The contractor shall arrange for the standby supply for testing of relays (viii) Painting with the approved coloure after preperationg of old surface as directed.
(a) Supply bushing 400 series bolted type
(b) Supply only O ring 72x6 bushing 400 series bolted
(c) Supply only SF6 Gass cylinder (9 Kg/cyl)
(d) Supply only shaft for operating handle
(e) Supply only 2PA machanisum w/o hex rod
(f) Supply only trip coil SAFEO force AMPL vic & ashda
(g) Supply only linkage between K and A
(h) Supply only ADR2415 NANO Relay with modbus
(j) Supply only push button red w/label `O'/green w/label `I'
(k) Supply only bracket A mechanisum hldg 2 push butoons
(l) Supply only opening finger & closing finger manual operating D & C
(m) Supply only 3 PKE mechanisum w/o Hex rod
(n) Supply only bracket for K machanisum
(o) Supply only bracket for CT MTG RMU RHS
(p) Supply only 24 KV VPIS cord
(q) Supply only capacitor unit VPIS 9-15 KV without cord
(r) Supply only leak detector : type LS790B leak seeker
(s) Supply only pressure refilling equipment (KAR-6)
(t) Supply only ronis lock & key for RMU with Key A
(u) Supply only ronis key with hardware
(v) Supply only ronis interlock of LBS with key C
(x) Supply only ronis interlock EL11P of LBS with Key B
(y) Supply only fuse holder assy
(z) Supply only terminal protector SILCAB for 11 KV
(aa) Supply only T rhroud (new) for 11 KV
(ac) Supply only reducer stud for cable bushing A
(ad) Supply only trip coil only Y1 control volts 24 volts VDC
(ae) Supply only close coil only Y2 control volts VDC
(af) Supply only O ring 65x5 for LBS mech bushing
(ag) Supply only spring charging motor with gear 30 /24volts VDC
(ah) Supply only wika make monometer+gas desity switch
(aj) Supply only electronic motor kit for C module-Mgvcl
(ak) Supply only standard motorised kit for V model
(al) Supply only bracket for RMU (new indication)
(am) Supply only position/local inicator
(an) Supply only saft
(ao) Supply only indicator flag C module OFF/ON/Plain
(ap) Supply only monometer assy -A
(aq) Supply only standard motorised kit for C model
(ar) Supply only battery 12 VDC, 12 AH
(as) Supply only unit VPIS 15-24V without cord
(at) Supply only S series bushing
(au) Supply only O ring for S series bushing
(av) Supply only VPIS bracket_B (for module -EL mechanism)
(aw) Supply only upper bracket for VIPS (for C model)
(ax) Supply only VPIS bottom (for V modul GPV Mech)
(ay) Supply only rubber boot and boot shuold be reychem/M seal/Dnson
(az) Supply only lethiem battery as per existing make/capacty/model
Periodical servicing to 11KV HT VCB any type complete including the following:- (a) Taking out 11KV HT VCB any type of 400/800 Amps rating from RMU Panel after switching off electric supply. (b) Checking of mechanical system for proper functioning of upward/downward or clock wise and anty clock wise movement of breaker. (c) Opening the VCB/RMU and replacmenet the unserviceable part as required at site. (d) Cleaning & servicing the fixed/ moving contact, busbar,cable boots with the CTC solution and greasing/oiling the parts where requied or as directed by manufacturer. (e) Tighting the all loos parts and testing complete as directed by EIC. (f) Setting the relay as directed by EIC. (g) Closed the all hole of VCB with ms jali and POP as directed by EIC (h) Repair the door/lock incl welding and replacement of lock/handle (j) Painting with the approved colour after preperation of old surface as directed.
Note- (i) Replacing new items shall be measured and paid seperatly as a supply only. (ii) Other part which is not included but requierd for functioning of equipment is included in the quoated rate. (iii) Remove the moisture from VCB/RMU by heating/CTC solution every three months. (iv) If any defect occurred at any place of Lucknow cantt area, the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and directed. (v) The above job to be carried out by engineer of authorised dealer/service centre of concerned OBC. (vii) The contractor shall arrange for the standby supply for testing of relays
(i) Supply only Isolating contact flat type 800/1250 A
(ii) Supply only Vaccum interrupter VG2
(iii) Supply only Breaker housing HVX-LR
(iii) Supply only Breaker housing HVX-HR
(iiiV Supply only insulating rod
(iv) Supply only VCB operating mechanism
(v) Supply only Closing coil 30 VDC
(vi) Supply only Tripping coil 30 VDC
(vii) Supply only Spring charging motor 110/30/24 AC/DC
(viii) Supply only Breaker Auxiliary switch 6NO + 6 NC
(ix) Supply only Motor cut off switch
(x) Supply only Main drive shaft assembly
(xi) Supply only Trip form linkage assembly
(xii) Supply only Ratchet wheel
(xiii) Supply only Pin for ratchet
(xiv) Supply only Handle block assembly
(xv) Supply only closing coil box assembly
(vi) Supply only Trip coil box assembly
(vii) Supply only Motor cut off lever assy
(viii) Supply only Trip prop support assy
(ix) Supply only Release lever
(x) Supply only Pin for release lever
(xi) Supply only Auxilary switch drive assembly
(xiii) Supply only Charging Pawl
(xiv) Supply only Buffer for spring
(xv) Supply only Over ride stop and in
(xvi) Supply only 24 pin plug and socket assy
(xvii) Supply only RYB busbar phase spout 800 Amp (upper and lower)
(xviii) Supply only Circuit spout
(xix) Supply only Spring charging handle
(xx) Supply only Limit switch assy
Supply,fixing,commissioning and testing VCB assembly(trolley) (HVX upto 800 A SCTC 25/26.3 ka spring charging motor 230 volts AC coil voltage 24 DC with out PT on trolley single trip etc complete as specified and directed incl taking down old one
Prediodical serving CSS of 11 KV rating, disconnecting the HT cables of any size and servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing of all moving parts,gas charging, tighting of all joints nut,bolt,washer, removing the moisture by jel/heating system of HT & LT side, Dehydration ¢rifuging tranformer oil and repair and replacement of defective components as per existing make/model/capacity of CSS & unserviceable wiring and reassembling the CSS incl connecting the all electrical connection and testing complete all as specified and directed. Note :-(i) The contractor shall arrange for the standby supply for testing of relays (ii) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system.(iii) Testing of above job to be carried out by engineers of authorised dealer/services centre of concerned OBC (iv) No extra payments will be made to the contractor for the same.(v) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt. (vi) painting of CSS as approved coloure (vii) Repair the gate by welding and replacement of hinges/lock as directed
(a) Supply only MCCB 3 pole 630 Amp 50 KA (TMR)
(b) Supply only MCCB 3 pole 100 Amp 35 KA (TMR)
(c ) Supply only Digital Voltmeter
(d) Supply only Digital Ammeter
(e) Supply only Winding temp gause
(f) Supply only Oil temp gause
(g) Supply only Battery as existing capacity12 V 12AH
(h) Supply only Power pack as per existing capacity 12V
(k) Supply only LED Indicator
(l) Supply only Shunt release
(m) Supply only Under voltage release
(n) Supply only Earth fault release
(o) Supply only Remote fault indicator
(p) Supply only Microswitch for indication
(q) Supply only UN-CO module for breaker control
(r ) Supply only Heavy duty capacitors
(s) Supply only Capacitor contractor 20 to 32 Amp
(t) Supply only Capacitor contractor 40 to 63 Amp
(u) Supply only APFC controller
(v) APFC relay as per exising make and model
(x) Heater as per existing make/model/capacity
S& F in repair spout suitable for existing size/model etc complete as specified and directed
S&F in repair aluminium bar bar as per existing size/thickness/sape with insulated etc complete as specified and directed
Supply only Elstein HFS panel heater 300 watt suitable for 11/33 kv VCB for removing the moisture
Supply only cast regin wound CT as per existing ratio/make/model/capacity
Supply and fix in repair pole of ABB make VCB as per existing model etc complete as specified and directed
Supply & fix in repair kit kat fuse witrh HRC fuse as per existing make/model/capacity
Supply & fix in repair Tnc switch as per existing make/model/capacity
Supply & Fix in repair Power Pack units with maintenance free solid batteries in sheet metal enclosure as per existing make/model/capacity
Supply & fix in repair high voltage fuse suitable for PT as per existing make/model/capacity
S&F in repair short & earth fault indicator as per existing make/model/size/capacity
S&F in repair phase sensor as per existing make/model/size/capacity
S&F Cold shrinkable, in door type, cable termination kit with all accessories suitable for 11 KV (earth) HT XLPE Cable of size 50 to 95 Sq mm 3 core incl disconnecting/connecting the cable in RYB phase sequence in pole/RMU incl cutting the unserviceable portion and testing after connection in all respect etc complete all as specified and directed.
Disconting the electric supply from RMU/VCB and taking out the rubber boot from cable and cleaning the moisture from boot and busbar with CTC solution /thinner in every month for smooth fucntioning of supply and conneting the electric supply and testing complete as specified and directed
Supply, installaation, testing and commissioing IP dome camera 2MP, 2.8mm fixed lens '1/2.8" ' progressive CMOS, ICR 1920x1080: 25fps (P) /30fps(N), H.265/H264, 3D DNR, BLC, HLC, 2VCA, IR range up to 40m, DC12V & PoE, support mobile monitoring, power supply incl taking down old one Made in inda BIS certified Make as approved by GE
Supply, installaation, testing and commissioing IP bullet Camera 2 MP, 6mm fixed lens ` 1/2.8" ' progressive CMOS, ICR, 1920x1080 : 25 fps (P)/30fps (N), H265/H264, 3 D DNR, HLC, 2 VCA, IR range upto 40 m, DC12V & PoE, support mobile monitoring, power supply made in India BIS certified including taking down old one Made in inda BIS certified Make as approved by GE
Supply, installaation, testing and commissioing 16 Ch network Video recorder with 1 sata and supports upto 5 MP cameras, H265+video encoding stand alone 1 U case Make in India BSI Certified incl taking down old one Made in inda BIS certified Make as approved by GE
Supply, installaation, testing and commissioing surveilance grade special made for video survellance Hardisk 4 Tera byte incl taking down old one Made in inda BIS certified Make as approved by GE
Supply, installaation, testing and commissioing power over ethernet enabled switch gigabit 4 ports with dedicated 2 ports uplink gigabite etc complete as specified and directed includig takaing old one Made in inda BIS certified Make as approved by GE
Supply, installaation, testing and commissioing PVC outdoor box for switch networing as per manufacturer norms incl taking down old one etc complete as specified and directed
Supply, installaation, testing and commissioing Network Rack 4 U with PDU as per manufacturer norms incl taking down old on eetc complete as specified and directed Make Top net or equivalent approved by GE
Supply, installaation, testing and commissioing premium full copper cat 6 cable roll 305 m as per manufacturer norms incl taking old one etc complete as specified and directed Make Wbox or equivalent approved by GE
S&F in reiapr pvc conduit ISI marked with all accessories etc complete as per manfactuere norms
Industrial Traders
BHATIA ENTERPRISES
NEW TECH ELCTRICALS
Ashirwad Contractor and Supplier
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .