Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹76 L
Closing Date
28 Sept 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Srinagar
Barbarshah Maisuma Srinagar
Internal Electrification of 2 BHK 4 Storey Block No 3 and 4 32 Flats At Pampore
2021_PWDJK_140461_2
E/NIT/112/2021/22dtd21/09/2021
Open Tender
Electrical Works
Item Rate
Internal Electrification of 2 BHK 4 Storey Block N
as per BOQ
7 documents required · 7 mandatory
₹1,600
Executive Engineer RNB Electric Division Srinagar
Exempted
28 Sept 2021
22 Sept 2021
28 Sept 2021
22 Sept 2021
28 Sept 2021
22 Sept 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (incl cost of conduit)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (incl cost of conduit)
Wiring for Power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required ( excl cost of Conduit )
Wiring for 6 Amp Socket Out Points 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required ( excl cost of Conduit )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supply and Fixing of two module stepped type Electronic Fan regulatot on the existing modular plate switch box including connections but excl cosat modular plate etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single Pole
Supplying and fixing 40-63 Amp 240/415V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
Supplying and fixing 32 Amp 240/415V, 2 Module Change over Switch fitted in excisting D Box incl making of necessary connections
Supply and Fixing of Neon Indicator Modular Switch Series incl its Frame Plate, cover plate and G I Box of required size
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply of 18 Watt Surface mounted Slim / Recessed type LED Fixtures.
Supply of 12 Watt Surface mounted Slim / Recessed type LED Fixtures.
Supply of 14 Watt Batten Type Al Base LED Light Fixture of standard make
Supply of 28 Watt Batten Type Al Base LED Light Fixture of standard make
Supply of 1400 mm sweep Ceiling Fans complete in all respects.
Supply of 300 mm sweep Exhaust Fans with steel body and steel blades incl wire guage shutter fron out side complete.
Supply of 36 watt LED street Light made of pressure die cast Aluminum Housing with high power LEDs, Lens & Toughened glass IP66 fitted on ornemental L Bracket Complete
Supply of AC / DC Bells with its Batteries.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
Upto 450 sweep
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Design, Fabricataion, assembly, Installation, Testing and Commissioning of Front Operated Cubicle type compartmentalised as per form 3B free standing, dust and verim proof (IP 42 ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable for a fault levewl of 55kA at 415 volts, fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted9 metal based neoprene) and lockable doors having structral reinforcement with suitable angle/ chanel/T / Flat section uncl gland plates as requiredand lifting hooks with sleeved TPN AL Busbars and G I strip of required size with 2 no earthinmg terminals complete with interconnections as required for MCB`s and control wiring. Each incoming / out going breakers shall have thermal megeatic release. The panel will be made as oper detailed specifications and drawings formating part of this document. Incomer :- 1 No 400 Amp TPN MCCB with beaking capacity 36kA with thermal release and adjustable settings. 1 Set of R,Y,B Phase indicating lamps 1 No MFM with 630/5CT coils 1 Set of 500 Amp TPN Alluminum Bus Bar with colour coding sleeves Out Going :- 20 No 100 Amp D Pole MCB`s 6 No 32-40 Amp D P MCB`s 3 no 63 Amp TPN MCB
Supply, laying, jointing, terminating, testing and commissioning of 240 sq mm 3.5 Core 1100 V grade, armoured, FRLS, XLPE, aluminum(AL) conductor cables of Havel's / Polycab / Universal / Fort Gloster on existing trays/walls/columns/ trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including the cost of proper dressing of cables, markers providing identification tags, earthing of glands armouring etc complete.
Supply of single spike air terminals of 16 mm dia following lengths as required and as per site conditions. the air terminal shall be manufactured with aluminium . The terminal shall be provided with the integrated / attached threaded base support suitable for mounting the terminals as per site condition. The base support shall be minimum 3 mm thick and shall have inbuilt connector fitting for connection of lightning conductor in such away that conductor contact area shall not be less than 40mm on all side of the conductor. The air terminals shall be supplied with the intermediate guy-wire supports to make it stable in case of high wind speed.
Roof Conductor for Parapet: Supply of 8 mm dia aluminium round conductor for air termination network at parapet wall with suitable accessories like type of clamps, conductor holder etc. as required and as per specifications.
Roof Conductor for Air Termination and for making mesh: Supply of 8 mm dia aluminium round conductor for making mesh & air termination network at terrace levels, to be installed on wall / parapet, with suitable type of clamps, hardware etc. as required.
DOWN CONDUCTOR AS PER IEC 62305
Supply of 8 mm dia aluminium round conductor for Down conductors to be installed on vertical façade of masonry / glass / metallic work, with suitable accessories like type of clamps, conductor holder etc. as required and as per specifications.
Supply of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value.
Supply of Expansion piece of made of 8mm conductor at every 20 mt to maintain the flexibility to the conductor due to heat.
Earth Termination Network:
Supply of 8 mm dia CCS, laid at 600mm below the ground, as Required and as per specification and code of practice.
Chemical Earthing with 3 mts long GI electrode to 50 mm dia G I Pipe placed verticaly in 100 mm dia bore dully drilled with hand drill and filed with required quantatity of chemical and man hole cover at top. The job includes extending of Earthing fron Eart Electrode to Main L T panel with 25x5 mm G I Strip in one run
Supply, Installation, Testing and Commissioning of UL/EN Listed Intelligent Addressable Multi Critera Dectors having optical & thermal Sensors. Operating Voltage Range 15 to 32V dc
Supply, Installation, Testing and Commissioning of UL/ENListed Addressable Hoter / Sound Supply Voltage 15 to 32 VDC( Non isolation) 15 to 28VDC ( Isolation)
Supply, Installation, Testing and Commissioning of UL/EN Listed Intelligent Addressable Manual Break Glass Call Point
Supply, Installation, Testing and Commissioning of UL/EN Listed Intelligent Addressable Control Modules.
Supply, Installation, Testing and Commissioning of UL/EN Listed 4 Loop Networkable, Multi Protocol Analouge Addressable Fire Alaram Control Panel having capacity of 99 devices per loop. The panel shall be able to give locataion of all fire and more fire / fault and isolation conditions od addressable units via the address code. the panel shall have capacity of storing up to 1000 events. Further the panel must be able to automatically switch on/off respectively control modules when ever any alaram is triggered. the panel should inbuilt common alaram. fault and monitored sounder out put. the poanel shall have a alpha numric LCD Displasy and having 160 characters in the display. The panel shall have a built in p[ower supply and battery charger,24 volt SMF batteries sufficent foir 24 hours in stand by and 30 mintues in alaram conditions the panel shall be compatiable for hard ware / soft ware.
Supply, Laying, Connecting and Commissioning of 2x1.5 sq mm FRLS insulated copper control cable in 25 mm dia medium mgrade PVC Conduit complete ( Incl cost of conduit)
M/S MUKHDOOMI ELECTRICALS
M/S ZAHOOR AND CO.
F M INFRASTRUCTURE BUILDERS PRIVATE LIMITED
M/S B.I.ELECTRICALS
Escon Electricals
M/S INTERNATIONAL STORES
M/S APEX ELECTRICALS and MECHANICAL ENGINEERING WORKS
M/S TAJ CORPORATION
stage.html
html • 0.03 MB
finance_293523.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .