Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.3 LAccepted-AOC N A | NEW DELHI | DELHI | 110001 | ₹98.3 L | L1 | Accepted-AOC Being lowest and reasonable tender |
| 2 | L2₹1.1 Cr+₹11.0 L (11.2%)Rejected-Finance | ₹1.1 Cr+₹11.0 L (11.2%) | L2 | Rejected-Finance Being second lowest bidder |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
27 Sept 2024, 6:00 pmClosed
CWE AF PALAM
CWE(AF) PALAM ,DELHI CANTT-110010
PROVN OF CCR BUILDING ALONGWITH ASSOCIATED INFRASTRUCTURE FOR CAT-III TAXIWAY AND APRON LIGHTING SYSTEM AT AF STN PALAM UNDER GE (AF) PALAM,DELHI CANTT-10
2024_MES_661143_2
CWE/PM/N-06/2024-25
Open Tender
Civil Works
Item Rate
365 days
GE AF PALAM
As per tender documents
10 documents required · 10 mandatory
₹1,000
GE AF PALAM
₹1.8 L
18 Nov 2024
6 Sept 2024
4 Oct 2024
6 Sept 2024
27 Sept 2024
13 Sept 2024
Amount
Surface dressing not exceeding 15 cm deep and getting out in Hard / Dense soil complete all as specified and directed.
Excavating over areas not exceeding 1.5m deep and getting out hard / dense soil complete all as specified and directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete etc. complete all as specified and directed.
M & L for RCC M–30 Design Mix, using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. complete all as specified and directed.
Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits [if any] of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces complete all as specified and directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc. complete all as specified and directed.
Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for rough finished surfaces of concrete complete all as specified and directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed.
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam launchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc, splays between floors and beams and similar works for rough finished surfaces of concrete complete all as specified and directed.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Slabs supported on walls, beams, columns, landings, shelves and the like complete all as specified and directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 5mm to 10mm dia bars as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and directed.
S & F GI wire cloth / mesh with 2 mm dia of wire, average aperture not exceeding 10mm and fixed with tinned tacks or stainless steel wire staples as in lateral reinforcement for pre-fabricated concrete wall panels/ modules complete all as per manufacturer's instructions, as specified and directed.
M & L for Brick work with subclass 'B' bricks,straight or curved on plan exc 06m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement Mortar 1:4 complete all as specified and directed.
M & L for Preparing the surfaces of concrete roof and brushing neat cement slurry with 3.0 Kg of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturer's instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 Kg per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M & L for 25 mm average thick, PCC 1:2:4, Type B-0, using 12.50mm graded aggregate as in Padding over roof slabs etc. including mixing water proofing compound as per manufacturer's instructions and finishing the top surface rough complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in cement mortar 1:4 including mixing water proofing compound as per manufacturer's instructions over a backing coat of 10mm thick in CM 1:6 on concrete or brick masonry surfaces and finishing the top surface even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral water proofing compound [ISI marked] of approved make complete all as specified and directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer of same manufacturer as that of paint on newly plastered walls, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vacuum based sanding machine complete all as specified and directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and directed.
M & L for preparing newly plastered Wall surfaces by using vacuum based sanding machine and applying two coats of oil base Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over 3mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and directed.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size exceeding 0.36 Sq.m but n exc 0.42 sqm, 8-10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size exceeding 0.36 Sq.m but n exc 0.42 sqm, 8-10 mm thick as in Skirting and Dado, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 350 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and directed. Note: The colour / shade / design of tiles shall be as approved by GE.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and directed.
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, check nuts,nipples,sockets etc fixed to walls, ceiling,roof/fixed inside shallow wells or laid on floors including testing complete all as specified and directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union,check nuts,nipples, sockets etc fixed to walls, ceiling roof/fixed inside shallow wells or laid on floors including testing complete all as specified and directed.
S & F Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and directed.
S & F Bib Taps, Long Body, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-107KN or its equivalent in Marc / Kohler complete all as specified and directed.
S & F Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and directed.
S & F Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and directed.
S & F PTMT Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges, fixed with and including Chromium plated brass screws and wooden/plastic cleats [Minimum weight 190 Grams] complete all as specified and directed.
S & F PTMT Soap Dish with screws complete all as specified and directed.
S & F Rotational Moulded Polythene [HDPE] Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and directed.
S & F Ball Valves, 25 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 25mm - 455 Grams] etc complete all as specified and directed.
S & F Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and directed.
M & L for 40mm bore dia High Density Polyethylene Pipes [HDPE] of pressure rating 6 Kgf / Sq.cm laid in trenches or fixed to walls or ceilings or in floors etc. complete all as specified and directed.
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F 75mm outlet PVC [SWR] Floor trap with grating including jointing with solvent cement complete all as specified and directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and directed.
S & F 110 mm bore PVC [SWR] Branch Piece, Single [Single "Y"] equal or unequal jointing with solvent cement complete all as specified and directed.
S & F 75 mm bore PVC [SWR] Branch Piece, Single [Single "Y"] equal or unequal jointing with solvent cement complete all as specified and directed.
S & F 110mm bore PVC [SWR] Gully Trap with grating including jointing with solvent cement complete all as specified and directed.
M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L for 75 mm thick, PCC 1:3:6, Type C-1, using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth complete all as specified and directed.
M & L for 100 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in sub floor/sub base, floor etc complete all as specified and directed.
M & L for 25 mm thick, PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in floor/sub floors etc complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement & fixing in frame at site as per specification complete all as specified and directed.
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, windows shutters sliding/ openable type/ ventilator shutter Aluminium section including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws and locking arrangements complete all as specified and directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I as approved by GE. [b] Supply only panel inserts of Glass / Gauze / Grills will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing and fixing only of panel inserts of Glass / Gauze / Grills etc.
S & F 75mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 75mm long complete all as specified and directed.
S & F Aluminium anodised barrel Tower Bolt of size 100 mm size of extruded section complete all as specified and directed.
Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 (7.2mmx4.2mm) including Powder Coated Aluminium Channel of size 30 X 12 X 1.5mm for fixing Deco Grill complete all as specified and directed.
Supply only 5mm thick Sheet Glass ordinary quality in squares exceeding 0.5 Sq.m in each pane complete all as specified and directed.
S & F Stainless steel curtain rod, 20 mm dia with fixing brackets, end caps etc complete all as specified and directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkhats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F Aluminium anodised barrel Tower Bolt of size 300 mm size of extruded section complete all as specified and directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and directed.
M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and directed.
M & L for providing pre construction anti termite treatment for the backfill in contact with foundation by applying emulsion at the rate of 7.5 litres per square metre of vertical surface [Area of the substructure in contact with back fill] complete all as specified and directed.
M & L for providing pre construction anti termite treatment for the top surface of filled earth by applying emulsion at the rate of 5 litres per square metre of surface complete all as specified and directed.
M & L for providing pre construction anti termite treatment for the soil under plinth protection by applying emulsion at the rate of 5 litres per square metre of surface area complete all as specified and directed.
M & L for providing pre construction anti termite treatment for the soil along with external perimeter of building by applying emulsion at the rate of 2.25 litres per running metre of the perimeter wall complete all as specified and directed.
M&L for Acoustic Door of 56 mm achieving sound reduction of up to 50 STC.Double layer of 10mm compressed insulation and single layer sound dampner size 1218x1218x12mm made of 10mm compressed wood fiber cement composites 1250 Kg/cum and 02mm dampner sheet having 37 STC as per ISO 140 (part-III)-1995.Door frame will be made of teak wood(sudan Teak). Three side frame and drop seal below will be provided along with the door with high load bearing hinges.
M&L for Sound Dampner tiles made of compressed wood particle cement of size 1218x1218x12mm made of 10mm cement composites 1250 Kg/cum and 2 mm dampner sheet having 37 STC as per ISO 354 , Installed on wooden stud with a backing of 50 mm 1000 GSM thick absorb wool tested as per fire retardant IS-15061-2002 for excellent result giving upto 40 STC complete all as specified and directed.
S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
M & L for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLSH multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories including modular metal flush box with modular plate for mounting switches, sockets, fan regulators, etc and earth wire single core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLSH cable as continuous earth wire connecting to common earth dolly in concealed wiring system including making good the disturbed surface of wall complete all as specified and directed by Engr- in- Charge for the following (ser item no. 80 to 83) :-
One light point controlled by one switch one way
One fan/exhaust fan point controlled by one switch.
One socket outlet 5 Amp controlled by one switch on independent board
One 3 pin 5Amps socket out let point on the same board controlled by one switch complete
All as per Srl item No 79 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed by Engr-in-Charge
All as per Srl item No 79 above but one power point 6 pin 15 Amps socket out let with 4.0 Sq mm stranded copper conductor cable PVC insulated including earth wire 4 Sq mm copper conductor cable connected to earth dolly complete, all as specified and directed by Engr-in-Charge.
S&F of modular switch 1 way 6 Amps one module complete all as specified and directed by Engr-in-Charge.
Supply and fixing of modular socket 6 Amps 2/3 Pin combined 02 module complete, all as specified and directed by Engr-in-Charge.
S&F of modular switch one way 16 Amps, one module complete, all as specified and as directed by Engr-in-Charge.
S & F of socket modular type 6 amp/16 amps, 2/3 pin combined 02 Module complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of ceiling rose, surface type, 65mm x 50mm, 2 to 3 terminal complete all as specified and as directed by Engr-in-Charge.
S&F of Indoor decorative LED battens- integrated type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bi-pin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge.
Supply and fixing of sheet metal enclosure for distribution board SPN (when MCBs to be used ) 12 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge
Supply and fixing of MCB, SPN, 40A ,10KA all as specified and directed.
Supply and fixing of MCB, SP, 6-32A ,10KAall as specified and directed.
Supply and fixing of MCB, SP 40 Amp ,10KA all as specified and directed.
S & F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB single pole 20 Amps complete all as specified and directed by Engr-in-Charge .
M&L for sub main wiring with under mentioned run of single core PVC insulated but unsheathed FRLSH cable of specified size multistranded copper conductor 1100 V grade IS-694 drawing into and including rigid non metallic PVC conduit, medium grade ISI marked ( not less than 25 mm) with all conduit fittings & fixing accessories for concealed in wall/ ceiling or surface including the specified run of specified size earth continuity conductor of similar type of cable complete all as specified and directed by Engr-in- Charge for the following (ser item no. 98 to 100) Note- The under mentioned runs of single core cable and specified earth continuity conductor and relevant conduit with fitting accessories will be measured as one run
4 run of 10 sq mm and one run of 10 sq mm earth wire
2 run of 6 sq mm and one run of 6 sq mm earth wire
2 runs of 4.0 sqmm one run of 4.0 sqmm earth wire
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
S&F Exhaust fan metallic body, complete 300 mm sweep 230 volts, single phase , AC supply with three core flexible copper conductor of suitable size for necessary connection complete with nuts, bolts and washers size of the bolts 06 inch long 6mm dia embedded in the wall including suitable hole for fixing of exhaust complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) AC supply with three core flexible copper conductor of suitable size for necessary connection complete all as specified and directed by Engr-in-Charge
S&F of Indoor decorative LED battens- integrated type 10 watt 2 feet white fixture with extruded aluminium body, suitable for LED tube 10 watt , bi-pin holder, connector block, LED rod 10 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and connecting up with three core flexible copper conductor 1.5 sqmm cable complete all as specified and directed.
S&F LED surface down light 18 Watt complete with all accessories internally pre wired and including connecting up with twin core copper conductor cable complete all as specified and directed by Engr-in-Charge
Supply and fixing of sheet metal enclosure for distribution board VTPN (when MCBs to be used ) 4 ways double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for MCCB, 4 pole 100A, 16KA, lcu = lcs, 415Volts complete all as specified and directed by Engr-in-Charge .
Supply and fixing of MCB TP 63Amps, 10KA complete all as specified and directed.
S & F of Triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 63 Amps complete all as specified and directed by Engr-in-Charge .
Supply, installation, testing and commissioning of high wall mount invertor AC split units indoor/outdoor with cordless remote control unit and within built air ioniser and synthetic fiber air filter for better indoor air quality with minimum 3 star BEE rating of Cap 2 TR which uses next generation R32 refrigerant for better cooling and low maintenance complete all as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning of water cooler fully anti rust stainless steel, ISI Marked electric driven single phase having appx storage 150 litre and nominal cooling capacity 150 litre/hour self adhesive and faucets low power consumption and CFC free R 134a refrigerant with energy efficient compressor complete all as specified and directed by Engineer-in-Charge. Make- Voltas/Bluestar/Sidhwal
Supply, installation, commissioning of air curtain of size 5 ft velocity- 15/16 mtr per second, effective air throw in mtr = 2.5, speed 1400 RPM, Noise level-70 DB with energy efficient, main & back plate MS powder coated complete all as specified and directed by Engineer-in-Charge, Make- Crompton Greaves/Almonard/Robustix
M&L for suction and discharge copper tubing of size 1/2 inch/ 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 1.5 TR capacity including soldering and brazing complete all as specified and directed by Engineer-in-Charge.
All as per item No 115 above but copper tubing size 5/8 inch / 3/8 inch dia and 0.5mm thickness complete all as specified and directed by Engineer-in-Charge
M&L for insulating the suction and discharge copper tubing from indoor unit to outdoor unit of split type ACs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves including sealing by applying adhesive tape of brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed by Engineer-in-Charge
S&F pre-fabricated AC stand suitable for wall mounting or floor mounting made with mild painted with synthetic enamel paint with anti vibration rubber pads including grouting in wall applicable for wall mounting type complete all as specified and directed by Engineer-in-Charge.
S&F nylon braided PVC pipe of size 20mm dia outer suitable for split AC drain including fixing accessories such as clamps, screws, rawl plugs etc. complete all as specified and directed by Engineer-in-Charge
S&F of electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5sqmm 4 core complete all as specified and directed by Engineer-in-Charge. Make- Havells/Polycab/CG
S&F of electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 4 sqmm 4 core complete all as specified and directed by Engineer-in-Charge. Make- Havells/Polycab/CG
M & L for Point wiring with single core PVC insulated but unsheathed 1.5 Sqmm FRLSH multistranded copper conductor cable 1100 volts grade IS-694 marked drawn in and including metallic stove enamelled conduit heavy duty grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories including all fittings for flame proof wiring and earth wire single core PVC insulated but unsheathed multistrand copper conductor cable 1100 volts grade IS-694 marked 1.5 Sqmm FRLSH cable as continuous earth wire connecting to common earth dolly complete all as specified and directed by Engr- in- Charge for the following (ser item no. 123 to 124):-
One light point controlled by one flame proof switch one way
One fan / exhaust fan point controlled by one flame proof switch
Supply and fixing of LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge.
Supply and Fixing of switch flame proof rotary type with termination box in LM6, 6A, single pole 250V complete all as specified and directed.
S & F exhaust fans flame proof AC single phase 240 Volts of size 450 mm ( 18") sweep 1440 RPM heavy duty with louvers complete with making holes and fixing on wall with 04 Nos fully threaded bolts and nuts , including connecting with 3 core flexible copper conductor of size 1.5 sq mm complete all as specified and directed by Engr-in-Charge.
Supply and fix flame proof MCB distribution board SPN 4 way with ML16 box complete all as specified and directed .
Supply and fix MCB SPN 5-32 Amps 230 V complete all as specified and directed by Engr- in- Charge.
Supply and fix MCB SP 5-32 A 230 V complete all as specified and directed by Engr- in- Charge.
M & L for copper strip 20 x 3.15 mm with saddles and fixing screws and joints with brazing including porcelain holder insulator for separation of strip as required at site etc for roof conductor, down conductor above ground complete all as specified and as directed by Engr-in-Charge.
M & L for Air termination, single pointed, copper rod 12mm dia and 300 mm long including fixing on GI pipe and necessary welding etc all as specified and as directed by Engr-in-Charge.
Material and Labour of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8 mm dia 25mm long hex. head screw complete all as specified and directed by Engr-in-Charge.
M & L for GI pipe medium grade 40 mm dia complete with all fittings and welding works complete, including taking out old unserviceable GI pipe all as specified and directed by Engr-in-Charge.
M & L for earthing with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5 metres below ground level, connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32x6mm galvanised iron strip including fixing on porcelain holder insulator for support on wall / roof etc with suitable size screw , nut bolts etc complete all as specified and directed by Engr-in Charge.
Supply and laying GI tubing medium grade 50 mm bore including all fittings such as bends, tees, nipples, check nuts, union etc., in trenches/ fixed on walls/ roof/ fixed inside the shallow well complete all as specified & directed
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe 50 mm dia complete all as specified and directed by engineer in charge.
Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe 20 mm dia complete all as specified and directed by engineer in charge.
Material & labour for CI special fittings of any size, any type ISI marked as required at site such as bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch. "Y" junction, double branch, cross (all socket or socket and spigot), collar, caps and plugs upto 150 mm bore etc. complete all as specified and directed by Engineer-in-Charge.
Material and labour for Construction of valve pit chamber having internal dimension 90 cm x 90 cm x 90 cm (internal height) using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick, 23 cm thick in CM (1:4), 10 mm thick rendering all around the brick work in cm (1:6) PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 8mm thick MS sheet cover with locking arrangement with and including 50 mm pad lock with double key arrangement, MS frame made out of 40 x 40 x 6 mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of metal primer including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition / dismantling of existing valve chamber complete all as specified and directed by Engineer-in-Charge.
M & L for augering of holes in true horizontal position under road (by trench less method) by means of mechanical rig covering in route up to 1.5 mtr deep and not exceeding 30mtr long for passing the water pipe lines of up to 100mm bore complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting of hard standing upto suitable thickness for fixing of any size/diameter pipe and filling with ready mix cement concrete and making good disturbed surface complete all as specified & directed .
M & L for cutting the existing CI/DI pipe of size 100/80 mm bore in position for inserting Tee of requisite size for taking branch connection etc. complete all as specified and directed by engineer in charge.
M&L for sand cushioning to underground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable i.e. total 23 cm complete and below 2 pole/ 4 pole structures and filling of ducts etc., complete all as specified and directed by Engr-in-charge. Note:- For the purpose of measurement only punned thickness will be measured as one unit.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete all as specified and as directed by Engr-in-charge
Supply & laying of un-reinforced Pre cast concrete cable covers conforming IS 5820-1970 class HV type 1 flat of size 300 x 180 x 40 mm laid in trenches as protection to cables complete all as specified and directed . Note :- Cable cover shall be tested as per IS- 5820-1970 from a Govt lab/NIT/IIT & test certificate shall be submitted before execution of work.
Supply, Installation, testing and commissioning of Transformer Outdoor type step down transformer, 11KV/433 Volts (at no load) AC 3 phase 50 Hz, 200 KVA capacity, core type copper wound, on HV & LV coil immerse, naturally cooled, Oil natural-air natural (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV side) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side ) and having 7 step tapings at +/- 2.5 % of each step (+5% to 10% ) on HV side to be changed by means of hand operated off load tap changer gear, the maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on and ambient temp of 40 degree celsius the transformer shall be in accordance with latest IS -1180 (Part-I) (Level 1) and comprise of the following:- (a) Three porcelain bushing suitable for 11 KV on HV side, and including and termination box complete with copper rods, nuts and washers. (b) One cable end termination box on LT side ( secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers. (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fill of dehydrating agent (silica gel) (e) Explosive vent, thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs/hooks, oil filling hole with cap/plug with connection plate complete, air release valve plug and four nos plain solid cast steel detachable rollers. (f) One no. 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-testing device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanized iron earth strip for earthing of body
ser item no. 148 contd... (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral (k) First filling of new transformer oil, IS-335 marked and tested up to 60 KV dielectric strength at 2.5 mm air gap between testing electrodes. Note: (i) Transformer shall be placed on PCC platform of size 2.5x2.5x 1.0 Mtr. (ii) Cost for Excavation, earth work, PCC and brick work etc shall be deemed to be included in the quoted rate by the contractor.
Supply, install, testing and commissioning of Servo Voltage stabilizer for automatic operation, three phase, 50 Hz, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 Volts per second and of capacity 200 KVA complete all as specified and directed by Engr-in-Charge.
M & L for XLPE insulated, screened PVC bedded , galvanized strip , armoured , electric power cable , heavy duty , with aluminium conductor 11 KV (E) grade ,cross sectional area 95 Sqmm 3 core., conforming to IS-7098 ( Part II) (amended upto date) including supplying, jointing and testing, complete all as specified and directed. Note: Excavation & earth work, cable protection and sand cushioning shall be measured & paid separately under appropriate item of this Schedule.
Supplying, laying, jointing and testing of XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable cross sectional area of 185 sqmm x 3.5 core 1100 volts grade with aluminium conductor conforming to IS-7098 (Part-I) (amended upto date) laid in trenches/ducts/along poles/ through pipes complete all as specified and directed by Engr-in-Charge. Note :- Earth work, sand cushioning, brick protection, hume pipe and cable tray shall be measured and paid separately
All as per ser. item No. 152 above but of size 95 sq mm x 3.5 core complete all as specified and directed
Supply and fix cable jointing kit for 11 KV (earthed ) grade cable for indoor termination (cable end joint) heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 Sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed
Supply & Laying GI pipe light grade 80mm bore for cable protection with all fittings for passing the underground cable under road crossing or along poles walls and floors, complete all as specified and directed by Engr-in-Charge.
Supply installation testing and commissioning of RMU SF6 insulated 11 KV,630 A 21 KA manual operated compact outdoor type, extensible, non draw out type ring main unit ( RMU) 3 way CVV+M ( 01No. load break switch as incomer) and 02 Nos VCB as outgoing ) switch gear with 630 A capacity bus bar completely enclosed in robotically/TIG welding stainless steel tank of suitable thickness as per IEC with IP-67 with and including suitable foundation , etc complete all as specified and directed . The RMU shall have separate compartment for PT with HRC fuse unit (ii) The outgoing VCB have microprocessor relay for O/C and E/F (iii) RMU shall be place in PCC platform as recommended by OEM and cost of excavation/ earth work and PCC shall be deemed to be included in the quoted rates . (Make- Crompton Greaves/ABB/Siemens)
Supply and fixing MCCB 160 Amps 3 pole 35 KA, lcu = lcs ,415 Volts 50 Hz with thermal adjustable magnetic settings including necessary connection all as specified and directed by Engr-in-Charge.
Supply and fixing MCCB 100 Amps 3 pole 16 KA, lcu = lcs ,415 Volts 50 Hz with thermal adjustable magnetic settings including necessary connection all as specified and directed by Engr-in-Charge.
M & L for earthing complete with copper earth plate electric 60 cm x 60 cm x 3.15mm buried directly and vertically in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to Copper strip 20 x 3 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and including necessary earth work execution in any type of latent rock, PCC 1:3:6 type C2 chamber and chamber cover 50mm (PCC 1:2:4) with 8 mm dia CTD reinforcement watering pipe 20mm dia GI, protection pipe for copper strip 40mm dia GI light grade, salt, coal, magnesium sulphate and water funnel etc complete all as per electrical plate No 3 of SSR Part I.( To obtained earth resistance value and prepare test sheet of newly constructed earth pit shall be responsibility of contractor ) Note :- If the desired earth resistance as per equipment requirement is not obtained the earthing shall be re-done by contractor without any extra cost to Govt .
M & L for chemical earthing complete with copper plate electrode 900mmx600mm x5mm thick buried buried directly in ground (earth pit not less than 4.0 Mtr below ground level) Earth plate connected to copper strip 50x6 mm dia light grade GI pipe from duly brazed earth strip protected with 80 mm dia light grade GI pipe from electrode and upto and including the earth test point of gun metal/phosphor bronze of 75x75x25mm 25 mm medium grade GI pipe including funnel, wire mesh alternate layer of thickness 15 cm each of charcoal (250 Kg) and common salt (200 Kg) and top layer of thickness15 CM Magnesium Sulphate including excavation and removal of surplus soil PCC (concrete chamber) shall be PCC 1:3:6 type B-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, all as shown in electrical plate No 3 of MES SSR Part-I and specified including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge. Note : If the desired earth resistance as per equipment requirement is not obtained, the earthing shall be re-done by contractor without any extra cost to Govt.
M & L Boring of holes under road/pavement / hard standing by trenchless technology using ultrasound technique and necessary machine including inserting of HDPE pipe of 150mm dia and jointing materials all as specified and directed by Engr-in-Charge. Note:- Necessary approval shall be obtained from user unit before commencing the boring work.
Supply, installation, testing & commissioning of maintenance free earth (grounding) electrode of size100mm Dia x 30.5 Mtr long with 17.2 mm Cu Bonded MS Conductor pre cast or in-situ cast in high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Electrode made of conductive earth enhancing material mixed with cement in the ration 3:1 to achieve result of earth resistance less than 1 Ohms encase or backfill the voids surrounding the 17.2 mm Cu Bonded MS conductor or other metal components placed in augured bore hole of 100 mm dia x 30.5 Mtr depth, resulting to increase in the effective surface area of the earth electrode or grids to lower the resistance. Earth enhancing material should not leach chemicals into the adjacent soil or underground water channels and should be in pH neutral range. Earth enhancing material should permanently protect the encased metal components of the earthing systems, copper bonding on MS rod should be minimum 250 microns. All hardware like nuts, bolts and washers should be of SS. Electrode should withstand fault current upto 35 kA for 1 second. Electrode's top terminal be sealed permanently packed with conductive concrete and Cu bonded MS / copper strip taken out be terminated on to earth test point and eqpt terminal. Test certificate of NABL laboratory shall be submitted by the contractor test link of size 50 mm X 6 mm X 200 mm, RCC pit cover including brazing of all the joints upto test point complete all as specified and directed by Engr-in-Charge.
M & L for 100 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in mass concrete etc complete all as specified and directed.
M&L for brick work in CM 1:4 with sub class 'B' bricks straight or curved on plan exc. 6m mean radius complete all as specified and directed.
M&L 15mm thick rendering in CM 1:4 on brick surfaces finished even and smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete , using extra cement , including forms , moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping ,benching in manholes,kerbs or mudstops, rounded or chamfered edges ,etc. including necessary form work & finishing the exposed surfaces of concrete even and smooth using extra cement complete all as specified and directed.
M&L for mild steel work as band straps, supports, stey hold fast, gratings and wall ties and similar small article conforming to IS- Fe 290 Gde 165. Note : Embedded portion of hold fast /wall ties shall be treated with tar of coal tar black paint complete all as specified and directed.
M&L for preparation of new untreated surfaces of any description over 10 cm in width or girth ,not otherwise described and priming with red oxide ,applying one coat of synthetic enamel paint complete all as specified and directed by engr-in charge.
Surface excavation in any type of soil, not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
M&L 25 mm thick Sand filling under floors or in foundation including consolidation complete all as specified and directed.
M&L 60 mm Machine pressed precast interlocking paver block any shape and size confirming to IS 15658-2006 , M-35 grade with grey cement and pigment fixed with cement complete all as specified and directed.
Excavation in trenches, n. exc 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n. exc 10 Sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, n. exc 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n. exc 10 Sqm on plan and n. exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches, n. exc 1.5 m wide but depth exceeding 1.5m and n. exc 3.00m for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n. exc 10 Sqm on plan and n. exc 3.00m in depth and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance exceeding 1.5km but n exc 5km and depositing where directed complete all as specified and as directed.
Removing excavated material to a distance exceeding 500m but n exc 1.5km and depositing where directed complete all as specified and as directed.
M&L for concrete bed to 150mm bore drain pipe in cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
Supply and Laying for 150 mm internal dia reinforced cement concrete pipes laid and jointed complete with collars class NP-2 laid in trenches and jointed complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on brick/concrete surfaces of walls including floating coat using water proofing compound as per Manufacturer's Instructions complete all as specified and directed by Engr-in-Charge. Note : WPC shall be measured and paid separately.
M&L PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation and bed concrete complete all as specified and directed.
Cutting into existing manholes for connecting new drains of dia 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed.
Supply and Fixing SFRC manhole cover size 1200mm x 600mm x 70mm thick with MS frame on man hole complete all as specified and directed.
S&F Mild steel work (framed) including stringers, treads, landing, balusters, hand rails etc. including cleats, brackets, ladders, walk way, railings and similar work etc. complete including cutting, welding with proper overlapping & welding with angle iron bottom as conforming to Fe 410 Gde E-250 complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new or previously untreated surfaces of wood of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over & including one coat of pink primer complete all as specified and directed.
S&F 15mm two in one angle valve chromium plated with wall flange and fancy type with high pressure screwed down and with CP flange of same make complete all as specified and directed.
S&F vitreous china urinal pot white (size 31cm x 37cm x 64 cm) including partition, waste pipe screwed with wall fixing complete. Make : Hindware Cat Part No 60010 or equivalent in Parry ware/Cera as approved by GE.
S&F Health faucet with double lock 1 meter brass plated stainless steel flexible hose and wall hook complete all as specified and directed. Make : Jaquar Cat Part No 563 or equivalent in Parry ware/Cera.
S&F CP paper holder of Make-AKP-35751P of Jaquar or equivalent in Kohler complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450 mm and fixed complete all as specified and as directed.
S&F corner glass shelf set of 3 Nos with bracket of Make ACN-1173 of Jaquar or equivalent in Parryware / Cera / Kohler complete all as specified and directed.
tarun construction co (BID ID -3102126)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .