Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 CrAccepted-AOC | ₹13.2 Cr | L1 | Accepted-AOC BEING L1 BIDDER |
| 2 | L2₹14.4 CrRejected-AOC | ₹14.4 Cr | L2 | Rejected-AOC NOT BEING THE LOWEST |
| 3 | L3₹15.0 CrRejected-AOC ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹15.0 Cr | L3 | Rejected-AOC NOT BEING THE LOWEST |
| 4 | L4₹15.2 CrRejected-AOC FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹15.2 Cr | L4 | Rejected-AOC NOT BEING THE LOWEST |
| 5 | L5₹15.9 CrRejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 UDYAM GJ 05 0006749 24AACFK2418A1Z4 B R MSME STATUS AS VERIFIED | BHAVNAGAR | GUJARAT | 364001 | ₹15.9 Cr | L5 | Rejected-AOC NOT BEING THE LOWEST |
Tender Value
₹14.5 Cr
EMD Value
₹10.5 L
Closing Date
28 Dec 2019, 6:00 pmClosed
HQ Chief Engineer (Navy) Mumbai
26, Assaye Building, Colaba Mumbai - 400005
PROVISION OF DEFICIENT INLIVING JUNIOR OTM ACCOMMODATION AT HANSA VIHAR
2019_MES_285872_1
87802/E8
Open Tender
Civil Works
540 days
HANSA VIHAR
As per NIT
9 documents required · 9 mandatory
₹3,000
Yes
GE (P) Vasco
₹10.5 L
Yes
9 Mar 2020
28 Sept 2019
31 Dec 2019
28 Sept 2019
28 Dec 2019
9 Dec 2019
28 Sept 2019 - 10 Oct 2019
Amount
Total amount of Sch 'A' Part-I (BUILDINGS & STRUCTURES) brought forward from Serial Page No. 28(R)
Total amount of Sch 'A' Part-II ( EXCAVATION , EARTH WORK, SITE CLEARANCE AND DEVELOPMENT) brought forward from Serial Page No. 30(R)
Total amount of Sch 'A' Part-III (INTERNAL & HOT WATER SUPPLY) brought forward from Serial Page No.31
Total amount of Sch 'A' Part-IV ( INTERNAL ELECTRIFICATION & TELEPHONE AND TV CONNECTION ) brought forward from Serial Page No.34(R)
Total amount of Sch 'A' Part-V ( SEWAGE DISPOSAL )brought forward from Serial Page No.36(R)
Total amount of Sch 'A' Part-VI ( AREA DRAINAGE )brought forward from Serial Page No. 37(R)
Total amount of Sch 'A' Part-VII ( EXTERNAL WATER SUPPLY ) brought forward from Serial Page No. 39(R)
Total amount of Sch 'A' Part-VIII ( EXTERNAL ELECTRIFICATION ) brought forward from Serial Page No. 42(R)
Total amount of Sch 'A' Part-IX ( COOLING APPLIANCES ) brought forward from Serial Page No.43
Total amount of Sch 'A' Part-X ( ROAD, PATH & CULVERT )brought forward from Serial Page No.45 (R)
Total amount of Sch 'A' Part-XI ( RETAINING WALL ) ) brought forward from Serial Page No. 46(R)
Total amount of Sch 'A' Part-XII ( RAIN WATER HARVESTING B&R & E &M WORKS ) brought forward from Serial Page No. 48(R)
Total amount of Sch 'A' Part-XIII ( ADDL WATER TANK FOR WATER COOLER ) brought forward from Serial Page No. 49(R)
Total amount of Sch 'A' Part-XIV (Chain link Fencing & Gate) brought forward from Serial Page No.50-A
Sch 'A' Part- XV - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
INTERNAL WATER SUPPLY :- S & F for concealed stop cock, Regular body with adjustable wall flange, size 20mm dia, Make - Jaquar Model No CQT-23089 or equivalent in Crab Tree/Kohler brand.
S & F for concealed stop cock, Regular body with adjustable wall flange, size 20mm dia, Make - Jaquar Model No CQT-23089 or equivalent in Crab Tree/Kohler brand.
S&F Health faucet with flexible pipe (ABS body) with 01 meter long PVC tube & wall hook Make Jaquar Model No ALD-chr-583 or equivalent in Crab Tree or Kohler brand
S & F Chromium Plated Push cock for urinal 15mm Bore Make Jaquar Model No PRS- 073 or equivalent in Crab Tree or Kohler brand
S&F Over head Shower 80 mm dia of ABS body chromium plated for fixing 15 mm size with bend of 45 degree with flange Make - Jaquar Model No OHS-1985 or equivalent
S&F 2-Way bib cock of 15 mm bore With wall flange Make- Jaquar Model No CQT-23041 or equivalent in Crab Tree or Kohler brand
S & F CPVC Gate valves suitable for size 25 mm outer dia CPVC pipe and fixed including threaded nipple and union Make:- Prince or Asthal
S & F CPVC Gate valves suitable for size 65 mm outer dia CPVC pipe and fixed including threaded nipple and union Make:- Prince or Asthal
S&F bib tap 15 mm dia heavy duty fancy type chromium plated finish with crutch or butterfly handle screweddown for CPVC pipe or for brass ferrule Make - Jaquar Model No CON 107 KN or equivalent as approved
EXTERNAL WATER SUPPLY:- Supply install test and commissiong of centrifugal Mono block pump set , electric driven complete with all accessories suitable for pumping water 350 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed. Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Supply install test and commissiong of centrifugal Mono block pump set , electric driven complete with all accessories suitable for pumping water 175 LPM discharge at 30 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items (flushing water supply pump for building) Note for item no 16 & 16.01 - Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served,
d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply and fix CI sluice Kirloskar/Upadhyay/L&T MAKE valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed of sizes 80 mm
Supply and fix CI foot valve, flanged end and drilled of size 80 mm dia ISI MARKED
Supply and fix CI double end flanged and drilled non return valve of size 80 mm dia PN-1.0 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix brass double end flanged and drilled non return valve of size 50 mm dia ISI MARKED Kirloskar/Upadhyay/L&T MAKE
Supply and fix CI 'Y ' Strainer screwed end or flanged type conforming to IS, size 80 mm dia.
Supply and fix CI 'Y ' Strainer screwed end or flanged type conforming to IS, size 50 mm dia.
Supply and fix Cast Iron Air Valves with single air Outlets 25 mm, conforming to IS 14845 for Cast Iron Water supply mains of size 80 mm dia.
Construction of brick masonry valve chamber of size 1000x 800x1000 mm (internal dia) including necessary excavation & earth work with bricks class designation 75, in CM (1:6) with PCC (1:4:8) type D2 for foundation including 15mm thick plastering in CM (1:4) inside the chamber and on the external portion exposed above ground level, including 3mm thick MS cover welded around with MS flat iron of size 40x6mm including MS angle iron frame of size 40x40x6mm with locking arrangement including painting with two coats of black bituminous paint over a coat of anti corrossive red oxide primer including including dismantling removing the existing damage chamber completely removal of debrisand depositing where directed by Engr - in- charge ( 01 no Ext Water Supply)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump )
INCOMING:-
(a) Incoming MCCB 32 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No
OUTGOINGS:-
(a) MCCB TP 20 Amps, 50 Hz, 415 Volts, 25 KA -06 Nos (For pump ,capacitor & lighting )
(b) Automatic DOL starter for 5 HP pump -04 Nos( For main pump)
(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(f ) Single phasing preventer -04 No
(g ) power capacitor bank , Utra heavy duty, BOX type Oil filled, LTXL OF L&T or equvalant of APCOS/siemens/momaya suitable for 480V,.5 KVAR- 1 no
Supply and Fix CI sluice valve both ends flanged and drilled , bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI , complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed of sizes 100mm dia. Make : kirloskar / Upadhyay / L & T
Supply and Fix CI sluice valve both ends flanged and drilled , bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI , complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed of sizes 80mm dia Make : kirloskar / Upadhyay / L & T MAKE
Supply and laying Ductile iron pipes with spigot and socket ends centrifugally cast , Class K-9 , in any length laid in trenches of size 80mm dia including rubbur Tytan joint
INTERNAL ELECTRIC SUPPLY
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x8/9 Watt ( for mirror light) ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 15 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting
S&F Fresh air Exhaust fan of size 230 mm sweep pvc body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Exhaust fan heavy duty of size 300 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. ( for Tech Building & Adm Building ) -Make : Crompton Greaves/ Bajaj/Orient
S & F MCCB DB VERTICAL TYPE suitable for 250 amps MCCB as incommer made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTH004DD/ LEGRAND / schneider/ ABB ( main DB for BUILDING)
S & F MCCB DB VERTICAL TYPE , suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ / schneider/ ABB ( For cookhouse) [ 01 no for Int Elect + 1 No 3 phase power supply ]
M & L for MCB TPN 415 Volts, 'C' series, breaking capacity 15 KA of rating 80 Amps
M & L for MCB TP 415 Volts, 'C' series, breaking capacity 15 KA of rating 80 Amps
MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 32 Amps ( for chimany) [ 01 no for Int Elect + 6 Nos 3 phase power supply ]
RCBO 30mA 2 Pole, breaking capacity 10 KA of rating 6-32Amps
MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu
MCCB 200 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu NOTE FOR ITEM NO 17.09 to 17.18 MAKE : LEGRAND/HAGER/SCHNEIDER/l&T
S &F MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98605OOOO /Legrand cat no-420055/schneider cat no-LV510317
S & F MCCB DB VERTICAL TYPE, suitable for 125 amps MCCB as incommer,made of sheet steel , powder painted with NEUTRAL bus bar 200 A, neutral link , IP-43-IK09 protection grade , 415 Volts TPN with 8 way Double door . Make : L & T CAT NO-DBVTL008DD / Legrand/ Schneider / ABB
MCB TP 415 Volts, 'C' series , breaking capacity 10 KA of rating 63 Amps
TELEPHONE & TV CONNECTION M&L for telephone jak with Modular metal flushed including flushed Box cover plate Box for 2 Way module
M&L for TV SOCKET with Modular metal flushed including flushed Box cover plate Box for 2 Way module
M&L for 2 pair telephone cable copper 0.5 sqmm dia
M&L for Coexel cable RG-6
EXTERNAL ELECTRIC SUPPLY
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Taking down unserviceable U/G cable from trenches, wall , floor etc and removing to store for safe custody above 35 sqmm upto 120 sqmm
Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B1 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix cable route indicator made of round CI disc embossed HT Cable, of size 16cm dia 6mm thick duly revetted with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm graded aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix LED street light fitting 35 Watts complete with bracket made out of 40mm dia GI light grade tubing not less than 1.5mtr long , bent to shape 120 deg including pole clamps (2nos), clamp made out of 30x5 mm flat iron for fixing GI pipe bracket and nut bolts and 15mm GI LG for controle cable from top of SMC box to bottom of light fitting bracket, washers etc all as directed
Supply & fix PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated , PVC sheathed wire 2.5 Sqmm copper & PVC coduit 20 mm dia. Make of Box- SPELS BERG/RITTAL/HENSEL CAT NO K8350
Supply, install, testing and commisioning of Distribution transformer mounted on masonry platform stepdown , 11KV,0.433KV , Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest amendments , Outdoor type, double opper wound suitable for 50 Hz system of capacity 160 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in steP of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.38 % & 0.96 % Respectivly as per GRIHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS . The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : -
(a) Lifting lug for transformer and tank.
(b) Earthing terminal rating and diagram plate.
(c ) Air release device.
(d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve.
(f) Conservator tank with oil level indicator
(g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
(k) Type of connection Delta/Star
(l) Type of cooling: Oil and Natural Air.
(m) Vector group:DYN 11.
(n) Temperature rise over an ambient of 50 °C maximum.
(o) Cable end box on both side for HT/LT cables of suitable size.
(p) Provision of thermometer with pocket.
(q) Provision of oil and winding temperature gauge.
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00 mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) [ 04 nos for Int Elect + 03 nos for ext elect + 04 nos for water harvesting + 04 nos RO plant + 08 nos Electric chimney ]
Supply, Installation, test and Commissioning CPRI approved factory fabricated, out door type, LT Pannel Board made out of 3.15 mm thick CRCA Sheet with projected globe roof for rain water protection dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - near transformer)
INCOMING:-
(a) MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92109OOP1OG /Legrand cat no-420249/schneider cat no-LV525343 - 1 no
OUTGOINGS:-
(b) MCCB 200 A 35 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92009OON1OG /Legrand cat no-420248/schneider cat no-LV525342 - 1 no ( main building)
© MCCB TP 125 Amps , 415Volts, 35KA ,3 POLE L&T CAT NO-SL98653OOOO/ LEGRAND CAT NO-420086 / equivalent of ABB - 3 nos ( cook house, APFC & sp power supply )
(d) MCCB TP 32 Amps , 415Volts, 35KA ,3 POLE,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider c(Outgoing) - 6Nos ( pump house , rain water pump , st light,borewell , RO Plant & spare)
(e) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no
(f ) Power contactor ML-1.5 , 3 pole rating not less than 16 A with 230 coil make L&T/SEIMENS - 1 no.
(g ) MCB SP 6 amps-1 no.
(h) Aluminum TPN bus bar 400 Amps - 01 Set
(l) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, outdoor type with projected Globe roof for rain water protection , double door, APFC capacitor bank Panel Board of size as recommended by manufactrer 40 KVAR with 6 steps ( 12.5+12.5+5+ 5+5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 3.15 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannel L&T/ SCHNEIDER/ABB
A INCOMER
MCCB 125 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & DN2-250D,CAT NO- CM920083OOM1OG- 1 no (Thermal Magnetic Release)
ROM+SPDR - 1 no
Auxiliary 1 c/o +TAC 1 c/o- 1 no
12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
40A, BUSSMANN FUSE- 6 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V - 2 nos
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
5 KVAr Capacitor feeder comprising of:- (3 Nos. )
16A, BUSSMANN FUSE 9 nos
Thyristor switching module 10kVAR, 440V,TSM,LTTSM
7% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-3 no
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 3nos
Push Button ON/OFF -6nos
Indicating lamps 6 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 3
6A DP MCB , C CURVE 3 NOS
Incomer Metering
APFC relay 8 stage {BLR CM – 06T MB } -1 NO [230/ 110 V, 1/5A, 50 Hz] [Transistor output + Single CT sensing + RS 485 MODBUS]
Digital Voltmeter (3Ph, Class 1) -1 NO
Digital Ameter (3Ph, Class 1, 5A) -1 NO
Metering CT --/5A, Class-1- 3 NOS
SMPS 5A, Input 230V AC Output 24V DC -1 NO
ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
Auxiliary Contactor {4NO} with 24V DC}-3 NOS
Indicating Lamp(R,Y,B)-3 NOS
6A SP MCB-3 NOS
6A DP MCB
6A FP MCB -1 NO
8" {EBM NADI} Fan -1 NO
M & L for Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) NOTE-: GI earth strip shell be measured and paid for separately under relevant item of schedule .[ 10 Nos External water supply + 20 Nos External Electrification + 2 RO Plant + 04 Nos water harvesting & chimany ]
HOT WATER SUPPLY Supply and Installation of solar water heating system, Flat plate collector type, with heat exchanger of 200 liter per day capacity, with electrical heating back up of 3 KW and make up water tank
Supply and fix PPR Gate Valves (Brass Insert) for size 25 mm dia. Pipe
Supply & Fix Bib cock, brass chromium plate screwed down for size 15mm dia pipe.
COOLING APPLIANCES
supply and fix refrigerator, electric driven (single phase), capacity 310 litres. BEE 5 star rated Make : LG, Voltas, Whirlpool as approved by GE.
supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 2.0 KVA Make : V Guard , Microtek , APC as approved by GE.
supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 1.0 KVA Make : V Guard , Microtek , APC as approved by GE.
RAIN WATER HARVESTING Supply, install test and commissiong of centrifugal MONOBLOCK pump set , electric driven complete with all accessories suitable for pumping water 600 LPM discharge at 20m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed. Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Note for Item no-22 - Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply and fix Foot Valve conforming to IS 4038, 40 mm (1.5”) dia
Construction of brick masonry valve chamber of size 600 x 600 x 900 mm (internal dia) including necessary excavation & earth work with bricks class designation 75, in CM (1:6) with PCC (1:4:8) type D2 for foundation including 15mm thick plastering in CM (1:4) inside the chamber and on the external portion exposed above ground level, including 3mm thick MS cover welded around with MS flat iron of size 40x6mm including MS angle iron frame of size 40x40x6mm with locking arrangement including painting with two coats of black bituminous paint over a coat of anti corrossive red oxide primer including including dismantling removing the existing damage chamber completely removal of debrisand depositing where directed by Engr - in- charge
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER ( main water supply pump )
INCOMING:-
(a) Incoming MCCB 32 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No
OUTGOINGS:-
(a) MCCB TP 20 Amps, 50 Hz, 415 Volts, 25 KA -03 Nos (For pump & lighting )
(b) Automatic DOL starter for 5 HP pump -02 Nos( For rain water harvesting)
(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(f) Single phasing preventer -02 No
ELECTRIC CHIMNEY Supply, install, test and commissioning Electric Chimney with SS Hood of size 168"x84"x21" with blower motor of 5 HP and fresh air inlet motor of 3 HP complete with piping, filters and other standard accessories complete. Make : Glen , Faber, Hindware, KAFF, Bosch as approved. Note : The SS duct shall be upto roof top.
INCOMER
(a) MCCB TPN 32 Amps , 415Volts, 35KA ,3 POLE,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -1Nos
OUT GOING
(b) MPCB 3 Pole, thermal release Adjustable range 6-10A for 3 phase motor of 4 KW (outgoing) for localised control and protection against overload and short circuit to 3 phase motors all as directed-02 Nos.(Make-L&T/ Legrand/Siemens/GE/ABB)
(c) MPCB 3 Pole, thermal release Adjustable range 5-8 Amp for 3 phase motor of 3HP for localised control and protection against overload and short circuit to 3 phase motors all as directed-02 Nos.(Make-L&T/ Legrand/Siemens/GE/ABB)
(d) DOL starter suitable for 5 HP three phase motors with inbuilt over load and earth fault relays, contactors, single phase, reverse protection-04 Nos. (Make- Legrand/Siemens/GE/ABB)
S.N. Constructions
Idustrial products India
M/s. P S REDDY
Krishna Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid