| 1 | L-1₹89.8 LAccepted-AOC COLABA MUMBAI | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹99.8 L+₹9.8 L (10.9%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹1.2 Cr+₹28.4 L (31.6%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹1.3 Cr+₹39.5 L (43.9%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L-4 | Rejected-Finance Being L-4 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
26 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
REPAIR FOR REPLACEMENT OF (13 PASSENGER CAPACITY) 05 NOS LIFT AGAINST BER AT DAD RESIDENTIAL ACCOMMODATION KANJURMARG, MUMBAI
2023_MES_627340_1
8455/E8
Open Tender
Civil Works
Item Rate
270 days
BHANDUP
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹2.2 L
Yes
25 Jan 2024
7 Nov 2023
29 Dec 2023
7 Nov 2023
26 Dec 2023
12 Dec 2023
Amount
Dismantling the existing BER Lift of capacity 13 Passenger lift (884 Kgs) of any make complete with all accessories such as reduction gear assembly ,Traction machine, electric motor control panel, guide rails and cabins, landing door and car door wire rope etc serving G+06 upper floor installed in bldg at DAD bldg A,B,C,D & E and deposit to MES Store yard complete all as specified and directed by Engr-in-charge. Note :- Before carrying out dismantling work of a particular lift the contractor shall first produce the procurement order for the entire material required for installation of new lift and shall obtain permission in writting from Engineer-in-charge to carryout dismantling of the existing lift in DAD bldg A,B,C,D & E .
Supply, install, testing & commissioning 884 kg, 13 Passengers Lifts suitable to serve G+06 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 2D infra red sensor in full height of door & built in announcing system without hand set (02 Nos, one each in car & near Ground floor landing door) all as specified below :- Location: DAD complex A, B, C, D, E wings. Note :Lift OEM to submit detailed specification/design parameters, construction drawings of all components of lifts as per IS-14665 for approval of accepting officer before execution of work.
Type of Lift :13 Passengers Load capacity :884 Kgs Speed : 1.0 mtr/sec with single speed motor Power Supply : 415 volts, 3 phase AC, 50 Hz Type of Drive : AC variable voltage & variable frequency drive. Type of Machine :Gearless & directly coupled Horizontal traction machine Car size (Inside) : Maximum size as OEM recommendation Car door & landing door :Center opening with VVVF door drive, opening size 900mmx2000mm, sliding type, fabricated by stainless steel sheet not less than 1.2mm thick having hairline finish (N- 304 ).at all floors Car enclosure : Standard manufacturing with MS frame & stainless steel sheet not less than 1.5mm thick with hair line finish (N-304) having stainless steel false ceiling with hair line finish, internal lighting arrangement with CFL/LED light fittings complete, internal ventilation system provided with concealed Arial flow/cross flow fan with auto cut off system & stainless steel/wire mesh for protection. Terminal buffers: Metal special spring buffers as per manufacturer specification. Door opening (Inside) : Protected by centre opening stainless steel doors with hairline finish doors with clear opening size about 900mm x 2000mm . Car & counter weight :Car Guide Machined 89 mm x 62 mm x 16 mm and CWT Guide machined 70 mm x 65 mm x 09 mm Guide Flooring :Aluminium chequered plate 5mm thick
Signals :- Combined luminous hall buttons with LED hall position indicators at all floor. LED for car position indicator to be fitted in COP made of stainless steel. Car operating panel with luminous buttons in car (stainless steel face plate ). Car direction indicator in car & Landing Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. Overload warning feature in car cabin(Display & audo buzzer type both). Fireman’s switch one No per lift to be installed at ground Floor near landing door. Fireman’s switch one No per lift to be installed at ground Floor near landing door. All signal fixture & car operating panel on stainless steel face plate with hair line finish. Infra red sensor safety edge of door for entire height. Built in announcing system without hand set.02 Nos( One for lift car & ground floor landing door &one announcing system , press & speak type, 3 way communication with machine room).
The interior of the car should be provided with a device that audibly indicates the floor position of lift car has reached and indicates that car entrance/exit door is open or closed. Stainless steel hand rail 32 mm dia all around 3 inside the car cabin. Door shall have AC-VVVF controlled close loop operated. Face plate shape shall be rectangular and stainless steel in hairline finish. Stops & Opening :07-07 ( All opening on same side)., G+6Safety device :(i) As per OEM design Automatic rescue device (ARD) /automatic landing device to be operating with maintenance free batteries for landing as specified. Make : As per OEM specifications & approved drawings. : (ii) Safety governor against over speed Car cabin as per norms laid down by PWD (Lift) Bombay with dual safety system including mechanical & electrical. Operation : Simplex, full collective automatic operation with/without attendant. Machine Room :Located above the hoist way Hoist-Way Construction :RCC wall construction as existing at site internal dimension 2500mm x 1900 mm, available AC- VVVF drive shall be of make :Yaskawa /Monarch/FUJI Control system :Microprocessor based with VVF Drive close loop type counter weight :Made of cast iron or MS Profile cut
One number wall mounted type telephone instrument of make Crompton Greaves / Beetel installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with trailing cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.
One number electrically operated siren, operating voltage 240 volts having audible range of 0.3 Km including independent switch inside of car cabin and connecting cables from car cabin to machine room. The siren shall be installed at appropriate place. (i) One toughened looking mirror (of best quality) of size 1100mm x 1100mm x 4mmthick with silvered sheet frame. (ii) One number CFL light to be connected with UPS for emergency lighting purpose.
Material & labour for 18mm thick mirror polished black granite slab, machine cut mirror polished cladding with chamfered/rounded edges approved decorative design including necessery PCC work granite slab & jointing in cement slurry and pointed in white cement mixed with pigement to match with shade of granite for lifts architrave at all floors complete all as specified and directed by Engr-in-charge.
Suppply and lay PVC insulated, armoured heavy duty electric cable with aluminimum conductor,1100 volts grade, cross sectional area 3.5 core 25 sqmm on wall of any height.The rate quoted by contractor includes existing taking out old unserviceable cable etc. complete all as specified and directed.
Material & labour for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected to lifts including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
Supply and laying galvanised iron strip of size 25x4mm from test point to lift machine room over the porcelain insulator provided at interval of 50 cm in such a way that galvanised iron strip should not touch to the wall and their should not be sharm bends/kinks etc. complete all as specified and directed.
M&L for sub main wiring complete with Two runs of 2.5 Sqmm single core PVC insulated unsheathed,heavy duty, 1100 Volt grade multistranded copper conductor cable (FRLS) and drawing through and including PVC conduit (minimum 20 mm dia) on the surfaces of the walls etc with all accessories, fittings etc and including one run of PVC insulated and unshethed copper conductor 2.5 Sqmm single core cable (FRLS) as earth continuity conductor, connected with earth dolly and mains including talling down old exising submain wiring complete all as specified & directed. Note: Three run of 2.5 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.
Dismantling the existing MCCB enclousure and Supply and fix MCCB Four Pole 100 Amps, 415 volts breaking capacity 25 KA 'C' Series rating with sheet metal enclousure complete all as specified and directed.
Dismantling the existing unsv MCCB and Supply and fix MCCB Four Pole 63 Amps, 415 volts breaking capacity 25 KA 'C' Series rating with sheet metal enclousure complete all as specified and directed.
Dismantling the existing load change over and Supply and fix Manual Changeover Switch On Load - 125A in sheet metal enclousure with Front Handle applicable in suitable for both horizontal as well as vertical mounting complete all as specified and directed.
S & F MCB DB, 08 way, SPN, double door, 240 Volts, fixed concealed/ surfaces on the wall, making all connections, complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
Supply and fixing RCCB 63 Amp rating 30mA, 240V, 10KA complete with connection testing and commissioning.
Supply and fixing SP 5 To 32 AMP amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) complete with connection testing and commissioning.
Escon Elevators Pvt Ltd
MB Enterprises
shakti engineering and electrical works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .