| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹15.6 LAccepted-AOC 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | l1 | Accepted-AOC L1 | |
| 2 | L2₹19.0 L+₹1.1 L (6.15%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.7 L+₹5.8 L (32.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
10 Feb 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Military Station Bikaner
Electrical Maintenance of KLP under AGE E/M at Mil Stn Bikaner under GE (N) Bikaner.
2020_MES_316179_1
GE (N) BKN-Token/61/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (N) Bikaner
Category D class b (i)
9 documents required · 9 mandatory
₹500
GE (N) Bikaner
₹50,000
Yes
16 Mar 2021
18 Jan 2020
12 Feb 2020
18 Jan 2020
10 Feb 2020
3 Feb 2020
Amount
Taking down ceiling fan for repair/serviceing (i.e. winding/ greasing/oiling etc.), 1200/1400 mm sweep of any make and any type model, sealing cable end with tape, dismantling the blades , removing fan and deposite the blades/motor to store for repairing/serviceing complete all as specefied and as directed by Engineer in charge.
Hanging only ceiling fan and connection up the point including provision of cable from ceiling rose to fan complete all as specefied and as directed by Engineer in charge. (Note: For the purpose of payment, the wire using ceiling rose to fan for connection shall be measured and paid seperately in approprite item and nothing extra pay for this item)
Re-winding of ceiling fan new model of size 1200 mm sweep with super enameled copper winding wire of gauge as per existing size /No. of wire confirming to IS, including varnishing the motor windings with best quality varnish , reassembling and testing complete all as specefied and as directed by Engineer in charge. (Make:Milan/Atlas/Chetak)
Ditto all as per item No 3 here in above but new model ceiling fan of size 1400 mm sweep complete all as specefied and as directed by Engineer in charge.
S&F in replacement of ball bearing of size/No. 6201 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NCB/SKF)
S&F in replacement of ball bearing of size/No. 6202 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NCB/SKF)
S&F in replacement of ball bearing of size/No. 6203 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NCB/SKF)
S&F in replacement of brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement of broken bottom cover (bowl) of PVC suitable for ceiling fan of any make and model complete all as specefied and as directed by Engineer in charge.(Make:bajaj/Kessels)
S&F in replacement of shaft for ceiling fan as per existing size and shape complete all as specefied and as directed by Engineer in charge.
Taking down and dismantling of exhaust fan 225mm/300mm/375mm/450mm sweep of any make and model, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully serviceable condition including replacing the defected worn out screw, flexible wire of size 23/0.0076 , oiling/greasing the fan and re-assembling the same and testing complete to the satisfaction of Engineer in charge.
Re-winding of exhaust fan 225mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish, reassembling and testing complete all as specefied and as directed by Engineer in charge. (Make:Milan/Atlas/Chetak)
Ditto all as per item No 12 here in above but of size 300mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but of size 375mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but of size 450mm sweep complete all as specefied and as directed by Engineer in charge.
S&F in replacement of blades for size of exhaust fan 225mm dully approved by GE complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but size of exhuast fan 300mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but size of exhuast fan 375mm sweep complete all as specefied and as directed by Engineer in charge.
Ditto all as per item No 12 here in above but size of exhuast fan 450mm sweep complete all as specefied and as directed by Engineer in charge.
S & F in replacement of condenser 04 MFD confirming to IS complete all as specefied and as directed by Engineer in charge. Make : Epcos/Bajaj/Asian
S & F in replacement of MS shaft for exhaust fan as per existing size and shape complete all as specefied and as directed by Engineer in charge.
S&F in replacement of MS back side cover for Exhaust fan of any sweep, size and make complete all as specefied and as directed by Engineer in charge.
Fixing only Exhaust fan and connection up the point including provision of cable from ceiling rose to fan complete all as specefied and as directed by Engineer in charge. (Note: For the purpose of payment, the wire using ceiling rose to fan for connection shall be measured and paid seperately in approprite item of this Schedule)
Taking down and dismantling of cabin/wall mounting fan of any size/make/sweep, opening the cover separating the motor and stator assembly, locating the fault and making the fan fully in serviceable condition including replacing the defective parts, fleaxible wire of size 23/0.0076, oiling/greasing the fan and re-assembling the fan, testing and refixing the fan complete all as specefied and as directed by Engineer in charge.
Re-winding the cabin/wall mounting fan with and including super enamelled copper winding wire of existing specification, gauge and weight including insulating materials and varnishing the motor windings with best quality varnish, reassembling and testing complete all as specefied and as directed by Engineer in charge.
S&F in replacement of brass bush suitable for cabin/wall mounting fan of any make/model confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement of push button cover of plastic suitable for cabin/wall mounting fan of any make/model with lock nut confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement down rod 30 cm long suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed by Engineer in charge.
S&F in replacement D Clamp with nuts, check nuts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed by Engineer in charge.
S&F PVC Canopies (Set of two) for ceiling fan of size 1200/1400 mm sweep as required at site and complete all as specefied and as directed by Engineer in charge
S&Fin replacement condenser 2.5 MFD confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: Tibcon/Orient/Epcos
S&F in replacement of flexible wire of size 23/0.0076 stranded copper conductor complete all as specefied and as directed by Engineer in charge.Make : Anchor / Plaza/Finolex
S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement complete all as specefied and as directed by Engineer in charge. Make : Anchor/Leader/SSK
M & L in replacement fan blade suitable for 1200mm sweep ceiling fan of any make complete all as specefied and as directed by Engineer in charge.
M & L in replacement fan blade suitable for 1400mm sweep ceiling fan of any make complete all as specefied and as directed by Engineer in charge.
Taking down old u/s electric meter with and including old cable from the switch board after disconnecting all electrical connections and depositing in MES store yard complete all as specified as directed by Engineer-in-Charge.
S&F temper proof electronic static watt hour energy meter LCD display of class 1.0 accuracy conforming to IS -13779 and CBIP Technical Report 88 and IEC 62052-11, IEC 62052-21, suitable for single phase system with optical port, 10-Amps (Basic) and 60 Amps (Maximum) capacity, duly encased in PVC housing with and including multi-stranded PVC insulated copper conductor cable/wire of size 6 sq mm cross-sectional area with bottle lugs for connections and connecting complete all as specified as directed by Engineer-in-Charge.
Supply and fixing temper proof electronic static watt hour energy meter LCD display of class 1.0 accuracy conforming to IS -13779 and CBIP Technical Report 88 and IEC 62052-11, IEC 62052-21, suitable for Three phase system with optical port, -60Amps (Basic) and 100 Amps (Maximum) capacity, duly encased in PVC housing with and including multi-stranded PVC insulated copper conductor cable/wire of size 10 sq mm cross-sectional area with bottle lugs for connections and connecting complete all as specified as directed by Engineer-in-Charge.
Taking down carefully existing unserviceable Copper/aluminum batten/surface conduit/concealed conduit point wiring (light, fan, bell/buzzer, socket or power) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, pendents, sockets, lamp holders, shades, fan regulators, light fittings, bells etc (including old MS sunken boxes) and removing the retrieved materials from dismantling including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and as directed by the Engr-in-Charge.
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including surface PVC concealed conduit Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in and including sunken box covered with and including 3 mm thick bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Make of cables :Havell's/Paragon/Nicco/L&T.Make of PVC Conduit : Polycab/Supreme/Modi/Finolex/Prince/Precision
M&L Point wiring with stranded copper conductor cable, 1100 volts grade (ISI marked) PVC insulated and unsheathed of size 1.5 Sq mm single core in and including PVC caping casing Medium class 20mm dia ISI marked with all fittings such as tees, bends etc terminating in and including sunken box covered with and including 3 mm thick bakelite laminated sheet top cover ‘Hylam’ for one fan or light or 5Amps socket or exhaust fan or bell/buzzer point controlled by one switch including provision of 1.5 Sqmm PVC insulated unsheathed copper conductor cable, single core as earth wire to common earth & connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Make of cables :Havell's/Paragon/Nicco/L&T.Make of PVC casing capping : Polycab/Supreme/Modi/Finolex/Prince/Precision
All as per item No 41 here-in-before but socket point on the same board with other switches complete as specifed as directed by Engineer - In - Charge
All as per item No 41 here-in-before but cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board including provision of 2.5 Sqmm PVC insulatred unshethed multistranded copper conductor as earth wire
All as per item No 41 here-in-before but in existing conduit .
All as per item No 41 here-in-before but in existing conduit cable of 2.5 Sq mm for 15 Amp switch socket outlet on independent board
All as per item No 41 here-in-before but one light point controlled by two 02 - way switch complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement LED T5 Batten lightening fixture, energy efficent 18/20 Watt ( 4 feet) complete all as specified and directed by engineer-in-charge make:-CG/ Havells/Phillips
S&F in replacement lamp holder PVC/Poly carbonate body with back plate complete all as specified and as directed by Engineer-in-Charge.Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement switch piano flush type, Single pole 5 Amps, one way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement of switch piano flush type, Single pole 15 Amps, one way, complete all as specified and as directed by Engineer-in-Charge Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement of socket outlet flush type, 3/5 pin, 5/15 Amps, complete all as specified and as directed by Engineer-in-Charge. Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement of socket outlet flush type, 3 pin, 5 Amps, complete all as specified and as directed by Engineer-in-Charge. Make - Havells. Cona, SSK, wipro, Legrand
S&F in replacement Switch piano flush type, Single pole 5 Amps, two way ISI marked, complete all as specified and as directed by Engineer-in-Charge Make : Anchor/ Legrand/Wipro/Havells
S&F in replacement switch socket combination 2 in 1, 5 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
S&F in replacement Switch socket combination 5 in 1, 5/16 amp flush type fixed on laminated sheet top cover (laminated sheet top cover is including in point wiring).
S&F Bell push flush type, 5 Amps, ISI marked, complete all as specified and as directed by Engineer-in-Charge
S&F Bell Buzzer, Ding Dong AC 230 Volts, single pole ISI marked, complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of PVC connector, ISI marked complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Tv socket flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge
Supply and fixing in replacement of Telephone socket flush type, ISI marked complete all as specified and as directed by Engineer-in-Charge
Supply and Fixing MCB single pole, 240 volts of rating 6-32 Amps of C curve breaking capacity of 10 KA complete all as specified and as directed by Engineer-in-Charge
Supply and Fixing MCB suitable for 6 to 32 Amps, 240 Volt AC supply C Curve single pole and neutral(SPN) with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement MCB 63 Amps, 440 Volt AC supply Triple pole with neutral(TPN) C curve with over load and short circuit protection having rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement Sheet metal enclosure for distribution boards flushed in wall Double door suitable for fixing MCBs 240 volts with 200 Amps rated bus bar,SPN 8 ways, including taking down of old unsv DB,s and making good the disturbed surface of wall, complete all as specified and as directed by Engineer-in-Charge. Make -L&T ( Exora series)/Schneider/ legrand/Schnedier/GE /English Elect Note : cost of cutting/chasing of wall and making good disturbed surface deemed to be included in the rate
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1Nos MCB 06 to 32 Amps capacity complete all as specified and directed by Engr-in-charge Cat Part No 607841 in Make Legrand or equivalent in schneider/Seimens/L&T
Sub main wiring in PVC casing capping/conduit with 2 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 10 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping all as specified and as directed by Engineer-in-Charge.(Note two run of 10 sqmm and one run of 10 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in PVC casing capping/conduit with 2 single core 04 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 04 sqmm copper conductor cable connected to common earth and earth dolly complete and including PVC Cassing and Capping all as specified and as directed by Engineer-in-Charge.(Note two run of 4 sqmm and one run of 4 sqmm will be measured as 1 RM.Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in PVC Surface conduit with 2 single core 10 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 10 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note two run of 10 sqmm and one run of 10 sqmm will be measured as 1 RM. Make of cables: Nicco, L&T, Paragon, havells
Sub main wiring in PVC Surface conduit with 2 single core 4 sqmm multi-stranded PVC insulated cable unsheathed 1100 volts grade with one earth wire of 4 sqmm copper conductor cable connected to common earth and earth dolly complete all as specified and as directed by Engineer-in-Charge.(Note two run of 4 sqmm and one run of 4 sqmm will be measured as 1 RM. Make of cables: Nicco, L&T, Paragon, havells
BIDAWAT ENTERPRISES
M/S ASHRAFI CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .