Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC CHANDURIA SIMURALI DIST NADIA PIN 741248 | NADIA | WEST BENGAL | 741248 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.8 L+₹58,865.39 (6.40%)Rejected-Finance F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | L2 | Rejected-Finance STOOD L2 | |
| 3 | L3₹9.9 L+₹70,878.73 (7.70%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L3 | Rejected-Finance STOOD L3 | |
| 4 | L4₹10.9 L+₹1.7 L (18.1%)Rejected-Finance | L4 | Rejected-Finance STOOD L4 |
| Sl No | Description | Qty | Unit | MILLENNIUM AIRCON L3 | ROY REFRIGERATION L1 | GITANJALI ELECTRONICS AND ELECTRICALS L4 | P. M. COOLING AND ENGINEERING CO L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Annual Comprehensive Maintenance 42 bedded Modern type Mortuary Cooler at Asansol District Hospital , Paschim Bardhaman as per terms & conditions.
Total Quantity-7 unit x 36 months=252 nos | 252 | nos | 3,300 ₹8,31,600 | 3,064 ₹7,72,128 Lowest | 3,620 ₹9,12,240 | 3,260 ₹8,21,520 |
| 1.01 | SCOPE OF WORK FOR MAINTENANCE:-
To check and service of the Mortuary cooler plant Monthly covering the following works:-
1. Checking of the 7 Nos 6 body Mortuary cooler plant performance, gas leak and oil return and also refrigerant system.
2. Checking the motors, starters, temparature controller with alarm system and other electrical equipments connected with the plant.
3. Lubrication of bearings of motor and blower fan etc.
4.Checking and rectification the operation of control panel and safety cut-outs.
5. Cleaning and discaling of the condenser once in a month as per direction of EIC.
6.Cleaning of cooling coil once in a month as per direction of EIC.
REPAIRING OF MATERIAL :-
1. Repairing the Mortuary cooler plant or repairing of parts thereof as and when necessary including cooling coil and temparature controller with alarm system.
2. Thorough overhauling of the 7 Nos 6 body Mortuary cooler plant once in a year as directed.
3. Pouring of refrigerant gas as and when required.
4. Painting of the Mortuary cooler plant once in a year with approved paint as per direction of EIC. | - | - | - | - | - | - |
| 1.02 | TERMS & CONDITIONS FOR MAINTENANCE:-
1. Maintanance & servicing of Mortuary cooler plant includes control panel, motors, condensers, blower fans etc. and electrical installation after main incoming source. (Excepet mortuary door & Door lock, hingh, door gasket & aluminium sheet metal cover, Mortuay Tray).
2. The contract covers preventive servicing once in a month.
3. This comprehensive contract covers preventive & corrective maintenance of Mortury plant / spare parts as required. So as to keep the Mortury Plant well operative / functioning round the clock as desired from performance and safety point of view.
4. Service Challan should be submitted to the AE concerned duly countersigned by the Junior Engineer-in-Charge of work. Room temperature at the time of servicing must be mentioned in the service Challan. Room temperature should be 40 ºF ±2 ºF.
5. The Log Book should be maintained and signed by the contractor or his authorized representative after completion of each phase of maintenance work under countersigned of the Junior Engineer concerned. In case of fault if so arises during maintenance work that should also be got signed by the contractor or his authorized representative noting the date & time of fault under countersignature of the Junior Engineer concerned. Date of repair of the same should also be signed by the Junior Engineer concerned with proper remarks.
6. In case any fault / breakdown it should be intimated to the Junior Engineer/Assistant Engineer at earliest. | - | - | - | - | - | - |
| 1.03 | 7. Service challan certifying satisfactory performance of the machines should be submitted to the concerned JE periodically after overhauling and that has to be countersigned by the AE and to be submitted alongwith the bill. Grill temperature for the Mortury plants have to be maintained within 40 ºF ±2 ºF keeping proper entries in the service challan.
8. Any fault should be set right within 48 (fortyeight) hours.
9. A certificate of Assistant Engineer concern giving satisfactorily performance to machine should be obtained before payment.
10. This contract covers repair and replacement of spare parts & accessories including blower motor, sheet metal body and repairing of condenser coil & copper tubes, Capacitors, relay, thermostat, air filters etc. as necessary and these spare parts / accessories should be available at site in the custody of the entrusted agency.
11. Any inconvenience caused so far as performance of Mortury plant is concerned due to negligence in the part of the agency, if detected, will be liable to penalty. Quantum of penalty would be decided by EIC depending on the gravity of situation.
12. While taking up / starting the comprehensive maintenance of Mortuary cold storage units, the agency will have to start maintaining this plants as per above terms and conditions irrespective of the condition of the Mortury plant and no extra charges will be paid for repairing / replacement work. | - | - | - | - | - | - |
| 1.04 | 13. The agency will have to provide self explanatory laminated photo identity cards and proper dresses with company’s logo for all the maintenance staff for need of Hospital Security reasons.
14. The behavior of mtc staff of the entrusted agency should be polite in nature and may be withdrawn from site in case of any adverse is reported. However, in normal cases, frequent changes of mtc staff will not be allowed without prior official intimation to the AE / JE.
15. No extra charges (Duties/ Cess/ Taxes etc.) will be paid except the rate quoted by the agency as per unit per month basis for maintaining the above described terms & conditions.
16. In case of any accident/ incident and or physical illness of the staff of entrusted agency while on duty, no claim will be entertained by this Department (P.W.Dte.) and all responsibilities thereof should be shoudered by the agency only. Minimum wages as per existing Labor Act should be paid to the staff.
17. Bill should be submitted bimonthly / quarterly as per direction of the EIC, keeping at least one spare log book at site and payment will be made on production of bill supported by documentary evidence.
18. The philosophy of "Public Interest" would be the MOTTO of this all inclusive comprehensive maintenance, any deviation may be viewed otherwise.
19. The concerned Executive Engineer reserves the right to terminate the contract against two months notice for performance not obser. | - | - | - | - | - | - |
| 2.00 | Add GST @18% On total from item no 1 to 1.04 | 1 | ITEM | 1,49,688 ₹1,49,688 | 1,38,983.04 ₹1,38,983.04 Lowest | 1,64,203.2 ₹1,64,203.2 | 1,47,873.6 ₹1,47,873.6 |
| 3.00 | Add LWC @1% On total from item no 1 to 2 | 1 | ITEM | 9,812.88 ₹9,812.88 | 9,111.11 ₹9,111.11 Lowest | 10,764.43 ₹10,764.43 | 9,693.94 ₹9,693.94 |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
11 Aug 2025, 6:55 pmClosed
EE.AED.PWD
Office of the Executive Engineer (P.W.D.) Asansol Electrical Division Near Polo Ground Dist Paschim Bardhaman PIN 713304
Annual Comprehensive Maintenance 42 bedded Modern type Mortuary Cooler at Asansol District Hospital, Paschim Bardhaman.
2025_WBPWD_882983_1
WBPWD/EE/AED /eNIQ-15/2025-26
Open Tender
ELECTRICAL WORKS M/R
Item Rate
1095 days
ASANSOL
Please refer Tender documents.
4 documents required · 4 mandatory
₹23,000
Office of the Executive Engineer P.W.D. Alsanso
25 Aug 2026
24 Jul 2025
14 Aug 2025
24 Jul 2025
11 Aug 2025
29 Jul 2025
28 Jul 2025
Amount
Annual Comprehensive Maintenance 42 bedded Modern type Mortuary Cooler at Asansol District Hospital , Paschim Bardhaman as per terms & conditions. Total Quantity-7 unit x 36 months=252 nos
SCOPE OF WORK FOR MAINTENANCE:- To check and service of the Mortuary cooler plant Monthly covering the following works:- 1. Checking of the 7 Nos 6 body Mortuary cooler plant performance, gas leak and oil return and also refrigerant system. 2. Checking the motors, starters, temparature controller with alarm system and other electrical equipments connected with the plant. 3. Lubrication of bearings of motor and blower fan etc. 4.Checking and rectification the operation of control panel and safety cut-outs. 5. Cleaning and discaling of the condenser once in a month as per direction of EIC. 6.Cleaning of cooling coil once in a month as per direction of EIC. REPAIRING OF MATERIAL :- 1. Repairing the Mortuary cooler plant or repairing of parts thereof as and when necessary including cooling coil and temparature controller with alarm system. 2. Thorough overhauling of the 7 Nos 6 body Mortuary cooler plant once in a year as directed. 3. Pouring of refrigerant gas as and when required. 4. Painting of the Mortuary cooler plant once in a year with approved paint as per direction of EIC.
TERMS & CONDITIONS FOR MAINTENANCE:- 1. Maintanance & servicing of Mortuary cooler plant includes control panel, motors, condensers, blower fans etc. and electrical installation after main incoming source. (Excepet mortuary door & Door lock, hingh, door gasket & aluminium sheet metal cover, Mortuay Tray). 2. The contract covers preventive servicing once in a month. 3. This comprehensive contract covers preventive & corrective maintenance of Mortury plant / spare parts as required. So as to keep the Mortury Plant well operative / functioning round the clock as desired from performance and safety point of view. 4. Service Challan should be submitted to the AE concerned duly countersigned by the Junior Engineer-in-Charge of work. Room temperature at the time of servicing must be mentioned in the service Challan. Room temperature should be 40 ºF ±2 ºF. 5. The Log Book should be maintained and signed by the contractor or his authorized representative after completion of each phase of maintenance work under countersigned of the Junior Engineer concerned. In case of fault if so arises during maintenance work that should also be got signed by the contractor or his authorized representative noting the date & time of fault under countersignature of the Junior Engineer concerned. Date of repair of the same should also be signed by the Junior Engineer concerned with proper remarks. 6. In case any fault / breakdown it should be intimated to the Junior Engineer/Assistant Engineer at earliest.
7. Service challan certifying satisfactory performance of the machines should be submitted to the concerned JE periodically after overhauling and that has to be countersigned by the AE and to be submitted alongwith the bill. Grill temperature for the Mortury plants have to be maintained within 40 ºF ±2 ºF keeping proper entries in the service challan. 8. Any fault should be set right within 48 (fortyeight) hours. 9. A certificate of Assistant Engineer concern giving satisfactorily performance to machine should be obtained before payment. 10. This contract covers repair and replacement of spare parts & accessories including blower motor, sheet metal body and repairing of condenser coil & copper tubes, Capacitors, relay, thermostat, air filters etc. as necessary and these spare parts / accessories should be available at site in the custody of the entrusted agency. 11. Any inconvenience caused so far as performance of Mortury plant is concerned due to negligence in the part of the agency, if detected, will be liable to penalty. Quantum of penalty would be decided by EIC depending on the gravity of situation. 12. While taking up / starting the comprehensive maintenance of Mortuary cold storage units, the agency will have to start maintaining this plants as per above terms and conditions irrespective of the condition of the Mortury plant and no extra charges will be paid for repairing / replacement work.
13. The agency will have to provide self explanatory laminated photo identity cards and proper dresses with company’s logo for all the maintenance staff for need of Hospital Security reasons. 14. The behavior of mtc staff of the entrusted agency should be polite in nature and may be withdrawn from site in case of any adverse is reported. However, in normal cases, frequent changes of mtc staff will not be allowed without prior official intimation to the AE / JE. 15. No extra charges (Duties/ Cess/ Taxes etc.) will be paid except the rate quoted by the agency as per unit per month basis for maintaining the above described terms & conditions. 16. In case of any accident/ incident and or physical illness of the staff of entrusted agency while on duty, no claim will be entertained by this Department (P.W.Dte.) and all responsibilities thereof should be shoudered by the agency only. Minimum wages as per existing Labor Act should be paid to the staff. 17. Bill should be submitted bimonthly / quarterly as per direction of the EIC, keeping at least one spare log book at site and payment will be made on production of bill supported by documentary evidence. 18. The philosophy of "Public Interest" would be the MOTTO of this all inclusive comprehensive maintenance, any deviation may be viewed otherwise. 19. The concerned Executive Engineer reserves the right to terminate the contract against two months notice for performance not obser.
Add GST @18% On total from item no 1 to 1.04
Add LWC @1% On total from item no 1 to 2
P. M. COOLING AND ENGINEERING CO (BID ID -6816899)
MILLENNIUM AIRCON (BID ID -6812520)
GITANJALI ELECTRONICS AND ELECTRICALS (BID ID -6828415)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .