| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC KHREW PULWAMA JAMMU AND KASHMIR 191103 | PULWAMA | PULWAMA | JAMMU AND KASHMIR | 191103 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹21.0 L+₹4.5 L (26.9%)Rejected-Finance | L2 | Rejected-Finance Quoted L2 | |
| 3 | L3₹23.8 L+₹7.3 L (43.9%)Rejected-Finance | L3 | Rejected-Finance Quoted L3 |
Tender Value
₹19.3 L
EMD Value
₹38,500
Closing Date
2 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Sriangar
Military Engineer Services Garrison Engineer (AF) Srinagar Air Force Station Srinagar-190007
PROVN OF CERTAIN WORKS SERVICES AT TECHNICAL BUILDING AT 1 WG, AIR FORCE STATION SRINAGAR
2022_MES_556677_2
GE(AF)SGR-35 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SRINAGAR
As per Tender Documents
10 documents required · 10 mandatory
₹500
GE (AF) SRINAGAR
₹38,500
Yes
23 Jan 2023
11 Nov 2022
3 Dec 2022
11 Nov 2022
2 Dec 2022
19 Nov 2022
Amount
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) sliding door shutter (Two panel) with frame, partly glazed with 5 mm thick tinted glass and partly paneled with 5 mm thick aluminium camposit panel including rubber bead joining cleat for fixing in position, each door shall be provided with 02 Nos of aluminium door handle 150 mm size, 02 Nos of aluminium barrel tower bolt 200 mm size, Minimum 03 rollers on top and min 03 rollers on bottom of each panel of shutter include guide channel etc all as specified and directed. Note:- Outer dimensions of the door shutter shall be measured for payment.
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel plate or other covering. Doors, etc. to be prepared for sliding with and including either hooks and hinges or steel hanging door fittings along with rollers for sliding and guide rails / channels etc (exclusive of steel plate or other covering) but including running rails and guides etc also fastening and fixing complete using steel section confirming of Fe-410-W (Gde-E-250) quality-B, all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, including fixed in position for door covering etc, confirming to Fe-410-W (Gde-E-250) quality-B, complete all as specified and directed.
Supply fabricate & fix in position Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, of Fe-410-W (Gde E-250) quality -B, complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard / dense soil, including removing of surplus soil complete all as specified and directed.
M&L for painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self drilling screws, complete all as specified and directed.
S&F pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self drilling screws all as specified.
M&L preparation of new steel surfaces, applying two coats of synthetic enamel paint over a coat of red oxide, over 10cm width or girth, not otherwise described, complete all as specified and directed.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floor and paving exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for plain cement concrete 1:1.5:3, type A1 (using 20 mm graded aggregates) as in floor with finishing surface of concrete fair & even, complete all as specified and directed by Engr-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for walling of squared rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed.
M&L for brickwork work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and directed.
M&L for broken stone or boulders hard core of gauge n.exc 63 mm, deposited, spread and leveled in layer n.exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including sides and soffits of beams, fascias, parapets etc and applying two coats of oil bound distemper over a coat of primer, colour and tint as ordered, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls including sides and soffits of beams, fascias, parapets etc and applying two coats of cement base paint over a coat of primer, colour and tint as ordered, complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
M&L for RCC 1:2:4 Type B1, using 20 mm graded stone aggregate as in foundation, footings, plinth Beam and similar RCC works all as specified and directed.
M&L for RCC 1:2:4 Type B1, using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts & similar RCC works all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft / loose soil
Returning filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
Removing excavated material exc 250 m but n exc. 500 m and depositing where directed at a level n. exc 1.5 m above the starting point, complete all as specified and directed.
Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat & fair finished surfaces of concrete.
Use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for square or rectangular and fair finish
M&L for steel reinforcement of TMT bars (Fe-550) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for steel reinforcement of TMT bars exc 8 mm but not exc 10 mm dia as in stirrups cut to length and bent to shape required including cranking, bending, hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n exc 4.00 Sqm each and credited to the contractor. Note: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface.
M&L for 75 mm thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base all as specified and as directed by Engineer-in-Charge.
M & L for dry river sand screed bed for PCC paver block, including gently compacting complete all a specified and directed. NOTE :- compacted thickness of sand will be measured and paid.
Material & Labour for machine pressed precast concrete interlocking paver block confirming to IS 15658, of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with white cement and pigment laid over existing screed bed complete
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft /loose soil,complete all specified and directed.
Supply, installation testing and commissioning of advanced early streamer emission Lightning protection system ( creates an upward stream to neutralise the lightning stroke above the building and hence protect the building , 79 meter radius of protection at level -I protection ( very high protection) with triggering time of 63 microseconds complete with all accessories as required , device confirming ti NFC 17-102 & 21186 STANDARDS. MAKE : SGI MODEL NO ese Taran or equivalents of make approved by GE.
Supply, installation testing and commissioning of Lightning transient event counter non resettable type 6 Digit mechanically display having IP 67 rating enclosure mounting arrangement etc complete all as specified and directed by Engr-in- Charge. MAKE : SGI MODEL NO ese Taran or equivalent of make approved by GE.
S&F Oblong test link joint to Discount the earth pit for testing etc complete as manufacture norms and specified and directed. Make :- SGI model no ESE Taran or equivalent of make approved by GE.
S&F 50 mm bore and 5 meter long mild steel galvanised iron tubing heavy duty as in post / mast for fixing / installation of lighting protection system , cut to size and erect in true vertical position including necessary foundation by excavation in any type soil , PCC 1:4:8 for foundation , brick masonry work in CM 1:4 , returning & filling & removal of surplus soil complete as specified and directed.
Supplying and laying XLPE insulated PVC inner sheathed , unarmored heavy duty underground cable with copper multistranded conductor 1100 volt grade size of 70 Sqmm, single core laid in trench /duct passing through pipe /duct or fixed on pole and connecting and testing complete.
Material and labour for earthing complete with copper earth plate electrode of size 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.5 m below normal ground level connected to copper earth strip of size 20 x 3 mm by means of bolts, nuts, check nuts and washers of copper and connected to main control board as directed and including provision of concrete pit in PCC (1:2:4) type B1, pre cost RCC earth pit cover reinforced with 8 mm dia TMT bars @ 150mmc/c of size 54 cm x 54 cm x 8cm with two handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galavanised steel tubing (med grade) for watering. Charcoal 250 Kg and salt 200 Kg in alternate layers, 40 mm bore galavanised steel tubing light grade for protection of earth lead connection including necessary excavation and earth work and testing complete all as shown on electrical plate No 3 of SSR Part-I
Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quote his rate accordingly.
Material & Labour for flame proof point wiring for one light / Fan point controlled by flameproof switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including stove enameled ERW steel conduit not less than 20 mm including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, complete Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
Material & Labour for three phase sub main wiring with 4 run single core multistranded copper conductor cable, of size 4.0 Sqmm, (3P+1N) PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run, single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete. Note: (i) 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material & Labour for three phase sub main wiring with 4 run single core multistranded copper conductor cable, of size 6.0 Sqmm, (3P+1N) PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 25 mm dia with all necessary fitting and including one run, single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete. Note: (i) 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
S&F Flame-weather proof rotary switch, single pole 16 Amps with termination box in LM6 and fixing arrangement complete all as specified and directed by Eng-In-Charge.
S & F Flame-weather proof switch socket & plug combined 25 A, 250 V (2P+Earth) with termination box in LM6, complete all as specified and directed.
S&F Flame-weather proof switch socket & plug combined 25 A, 250 V (3P+Earth) with termination box in LM6, complete all as specified and directed.
S&F Flame proof, weather proof FLP - WP WELLGLASS WITH THREADED DESIGN (NEW) WG / OA / 1234, 18W LED incl fixing arrangement with all accessories Integral (New) prewired, product in Al. die cast alloy LM6 construction with ISI marking including testing complete all as specified and directed.
S&F Flame proof, weather proof Sheet metal enclosure for DBs in LM 6, suitable for and including one No MCCBs Triple pole and neutral 100 Amps as incoming, 04 Nos MCCB triple pole 25A as outgoing including all connection complete all as specified and directed.
S&F Flame proof, weather proof Sheet metal enclosure for DBs in LM 6, suitable for and including one No MCBs Double pole 63 Amps as incoming, 06 Nos MCB Single pole 25A as outgoing including all connection complete all as specified and directed.
Supply and lay factory made un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-Charge. Make:- MEHTAB TILES, PEARLESS INDUSTRIES, HINDMOZAIC OR STATE ELECTRICITY BOARD APPROVED MANUFACTURER.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engr-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
Supply & lay XLPE insulated, PVC inner sheathed, armored with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete. Note:- Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule.
S&F of on load Changeover switch 100 A FP in sheet metal enclosure, suitable for operation of incoming and outgoing cable for standby supply complete all as specified and directed by Engr-in-charge
Supply and fixing of factory made CPRI approved LT feeder pillar box outdoor type factory made weather and vermin proof made out from 3.15 mm sheet supported with legs 45 cm long made of angle iron 50x50x5 mm of size 0.6 mtrx 0.5 mtrx 0.4 mtr with MCCB 100A 4-Pole-01 Nos with proper fixing arrangement of suitable size of nut , bolt, washer complete incl incoming and outgoing LT Cable connection with front and rear side openable with locking arrangement suitable for 1100 V LT. LT panel painting with two coats of smoke gray synthetic enamels paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note:- Feeder pillar box shall be mounted on brick plate form built in (1:4) not less then 60 cm above ground level with suitable PCC foundation rendering 15 mm in CM (1:6), applying two coats and cement base paints and supported on 04 nos angle iron with concrete base.
Material and labour for Chemical earthing complete with copper earth plate electrode 900 mm x 600 mm x 5 mm thick, placed horizontally and buried directly in ground (earth pit not less than 4.75 metre deep below normal ground level) with top edge of the plate not less than 4.00 metre deep below normal ground connected with copper strip 32 x 6 mm by means of brazing, providing and filling of charcoal dust and common salt in 150 mm in alternate layer at least 150 mm all-around and bottom edge of earth plate, providing and filling 500 mm layer of magnesium sulphate from top edge of earth plate, watering pipe of 50 mm bore galvanised iron light grade with funnel and 50 mm bore galvanised iron light grade pipe for earth strip protection, including all excavation / earth work in any type of soil, PCC pit (size as per electrical plate No 3 of SSR Part -1) in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), complete including testing on completion.
Note:- (i) Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length, and extra length will be measured & paid separately. (ii) Qty of Charcoal dust 250 Kg, Common salt 200 Kg, and magnesium sulphate 100 Kg shall be used for each earthing.
S&F earth continuity conductor or main earthing strip of Copper strip of size 32 x 6 mm, fixed to wall / chases or buried in ground or drawn through conduit in any position or any other situation for loop earthing etc with and including epoxy insulators with necessary fixture complete all as specified and directed by Engr -in - Charge
MEGA CONCRETE CONSTRUCTION ENGINEERS AND CONTRACTORS
M/S A.R.TANTARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .