| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹32.8 L+₹2.8 L (9.28%)Rejected-Finance JAISALMER | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.6 L+₹6.6 L (22.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Apr 2024, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR MAINT OF SEWAGE LINES, MANHOLES AND MANHOLE COVER AND STP LINE IN DOMESTIC AREA AT AF STN JAISALMER
2024_MES_647211_1
8217/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹80,000
Yes
14 Jun 2024
20 Mar 2024
20 Apr 2024
20 Mar 2024
18 Apr 2024
4 Apr 2024
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of drain pipes, or for manhole, etc., not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil all as specified and directed by Engr - in - charge.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed by Engr - in - charge.
Removing excavated material nexc 50mtr and depositing where directed at a level n exc 1.5m above the starting point
Demolation and breaking up drain pipes of 150 mm dia (Salt glazed ware ,AC or Reinforced concrete ) set in cement mortar including bedding haunching complete all as specified and directed by Engineer-in-Charge
M&L in replacement of 150mm bore pipe reinforced concrete, class NP2, laid and jointed complete with collars complete all as specified & as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete.
Demolition of stone/brick masonry built in cement mortar including coping etc all as specified and directed by Engr - in - charge.
M&L for precast cement concrete solid blocks ( 1:3:6 ) type C-I (using 20mm graded stone aggregate) exc 10cm in width as in block masonry built in CM 1:4 etc complete all as specified.
Taking down cement plaster of any discription on any surfaces, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 10mm thick plaster in cement mortar (1:3 ) on concrete surfaces or masonry surfaces as in manholes,gully traps etc and finished even and smooth without using extra cement complete all as specified.
Demolition of cement concrete in any position not otherwise specifically provided complete all as specified.
M&L PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) in coping, benching of manholes etc, and including necessary formwork and including demolition of existing PCC complete all as specified and directed by Engr - in - charge.
M&L pre-cast RCC 1 : 2 : 4, type B-1 (using 20 mm graded stone aggregate) in cover slabs for man holes etc, set in CM I : 6 and including demolition of old slabs complete all as specified and directed by Engr - in - charge.
M&L MS TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed by Engr - in - charge.
S&F Providing SFRC manhole covers with rectangular frame of size 44"x26" MD-10 fixed at site up to satisfactoin of Engr-in-Charge and including dismentling of old manhole cover slab complete all as specified.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.
M&L for Jodhpur stone roof slabs, self faced 7.5 cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in lime mortar 1:3 or cement motar 1:6 complete)
M&L for removal of blockage in between WC and nahani trap/WC to Ist manhole / floor trap to nahani trap etc. by flexible roding and removal the all dirt up to a distance of 100 m all as directed.Note : (i) In case a blockage reoccured with in 7 days the same shall be removed without any extra cost of the Govt. (ii) Cleaning of line in between manhole where in the blockage remove shall deemed to incl the rate coated. (iii) If contractor failed to clear the blockage with in 24 hours from the receipt of complaint, a penalty of Rs 50 per day will charge up to 7 days and after 7 days same will be Rs 100.00 till completion of complaint.
De-watering of septic tanks/soakage wellslGrease trap of any size and any depth by pumping with trolley mounted pump sets including carrying the waste water in closed containers and unloading it out side the MoD land at location shown by Engr-in-Charge at a distance n. exc 5 km from the starting point. septic tanks/soakage wells/grease trap of any size/depth complete all as specified and as directed by the Engr-in-Charge\nNote:-\n(i) Hydraulically driven high pressure pump, capacity of 295L/min at 135 bar.\n(ii) Hydraulically driven high pressure pump, having 1850 cum/hr Suction Pressure.\n(iii) Rear hydraulic driven hose reel with 120m jetting hose.\n(iv) Proper safety of the operator during operation.\n(v) Rate shall be deemed to included in quoted rate.
Cleaning and desilting of manholes of any size,depth not exc 1.50 mtr by excavating sewage wet/dry soil in foul condition and removing the waste in covered vehicles outside MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manhole, placing the cover of manhole in position and removing the sludge in covered van/trolley out side the MD land, complete all as specified and directed.
Cleaning and desilting of manholes of any size,depth exc 1.5 mtr but not exc 3.0mtr by excavating sewage wet/dry soil in foul condition and removing the waste in covered vehicles outside MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manhole, placing the cover of manhole in position and removing the sludge in covered van/trolley out side the MD land, complete all as specified and directed.
Cleaning and desilting of manholes of any size,depth exc 3.0 mtr but not exc 4.5 mtr by excavating sewage wet/dry soil in foul condition and removing the waste in covered vehicles outside MD land by taking all necessary precautions and including pumping out fluid, cleaning of sludge from manhole, placing the cover of manhole in position and removing the sludge in covered van/trolley out side the MD land, complete all as specified and directed.
Cleaning solid /liquid mud deposited in under ground sewage lines, upto and including 150mm dia bore, of any type, between consecutive manholes, by hydraulic jet pressure machine, through connecting manholes, complete men, machine and water as required , including removal and refixing of manhole covers, complete all as specified and directed
Cleaning solid /liquid mud deposited in under ground sewage lines, upto and including 200/300mm dia bore, of any type, between consecutive manholes, by super sucktion machine, through connecting manholes, complete men, machine and water as required , including removal and refixing of manhole covers, complete all as specified and directed
S&F 180mmx150mm size Salt-glazed stoneware gully traps, square or round mouthed, tvpe 'P' complete all as specified and directed.
S&F in repair water closet squatting pan 'Orissa Pattern'of size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe) with P' or 'S' trap complete incl. jointing and provision of PCC 1:5:10 bed as in repairs complete all as specified and directed.
S&F repairs Vitreous china wash down water closet pan (pedestal pattern) with any type of 'P' or 'S' trap excluding flushing cistern and flush pipe, including fixing of water closet complete with plastic water closet seat black/white closed pattern witrh flat bottomand cover and mild steel chromium plated or aluminised hinging device. complete all as specified and as directed.
S&F in repair PVC 10 Ltrs valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved complete all specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
S&F glazed ceramic colour tiles 300x200 & 450X 350X 7mm thick on vertical surface such as skirting, dado, set and joint in neat cement slurry and pointed in white/coloured cement to match with existing surface make complete all specified and directed by Engr-in Charge.
M&L non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm in floors etc over and including 15 mm thick screed bedding in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls & floor complete all as specified and directed.
S&Fin Repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls & floor complete all as specified and directed.
S&F in Repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm dia pipe complete all as specified and directed.
S&F in Repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm dia pipe complete all as specified and directed.
S&F in Repair 110mm bore PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified & directed.
S&F in repair 110 mm dia PVC (SWR) bend any radius complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) bend any radius with access door complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) Junction single (Single T) equal or unequal with access door complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) branch piece single (single Y) equal or unequal with access door complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) vent cowl complete all as specified and directed.
Demolition of PCC of any description not otherwise specially provided for complete all as specified and directed.
Cleaning of roughened surface of sunken floor by brushing with wire brush to remove all dirt and apply a coat of cement slurry with 3.00 Kg of cement per sqm and Rendering 15mm thick in CM 1:3 using WPC finished rough (sunken floor/wall) and then applying two course treatment as follow :- (i) Applying bitumen primer @ 0.40Kg/Sqm (ii) Laying APP (Atactic polypropylene) modified membrance 3mm thick and weighting not less than 3.50 Kg/Sqm with 100 GSM/Sqm non woven polyester mat as center core reinforcement, laid with 75 mm side over lap and 100mm end over lap. The membrane has to be laid with LPG torch and over lap sealed and finished neat. (iii) 40mm bore GI pipe for spout pipe length 0.75m
Lime concrete with stone agg in lime mortar 1:2 as filling in sunken floor as in any situation complete all as specified and directed.
Cement concrete (50mm thick) type B-1, 1:2:4 (20mm graded aggregate) as in floor complete all as specified and directed.
Taking up or down mild steel tubing and connections 15 mm bore complete all as specified and directed.
S&F steel water tubing `medium grade’ galvanized 15 mm bore with all fittings and fixed complete to walls and ceiling concealed and joints fixed with adhesive complete all as specified and directed.
JASOL MAA ENTERPRISES
M/S R B CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .