| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 212 338 OLD DALANWALA DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical C 8 78A KESHAV PURAM DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹94.5 L
EMD Value
₹1.9 L
Closing Date
10 Nov 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Project Director
Office of the Project Director, FRFCF-NRB, Kalpakkam
Design, Manufacturing, Installation, Testing and Commissioning of 11kV XLPE Power Cable, Grounding system and its associated works at CWCP, FRFCF, Kalpakkam
2026_BARC_931201_1
BARC/NRB/FRFCF/ELE/ETR020/2026
Open Tender
Electrical Works
Item Rate
365 days
FRFCF, Kalpakkam
Please refer tender document
8 documents required · 8 mandatory
₹0
₹1.9 L
18 Nov 2026
22 Oct 2026
18 Nov 2026
22 Oct 2026
10 Nov 2026
22 Oct 2026
22 Oct 2026 - 5 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fabrication, manufacturing including design, inspection and testing at manufacturer’s works, documentation including submission of relevant data, packing, transportation from manufacturer works to site, unloading and installation in ground, testing at site and commissioning of 6.35 / 11 kV (E) grade, 3 Core X 400 Sq.mm, stranded compacted & circular Aluminium water tight conductor followed by semi conducting water swellable tape, conductor screen with Extruded semi conducting compound, Extruded WTR XLPE Insulated, Insulation screening with Extruded semi conducting compound, followed by water swellable semi conducting tape and single layer of copper tape(suitable to carry 1.12 kA/1 sec each core) and water swallable semi conducting tape, cores laid up with center filler, Extruded FRLSH PVC type ST-2 inner sheath followed by layer of poly Al. tape and HDPE type ST-7 intermediate sheath followed by single layer of Galvanized steel round wire armoured and overall Extruded FRLSH PVC type ST-2 sheathed cable generally conformes to IS 7098 part-2 and IEC 60502-2 with latest amendments and as per the tender specification. | 180 | Mtrs | - | - |
| 2 | Fabrication, manufacturing including design, inspection and testing at manufacturer’s works, documentation including submission of relevant data, packing, transportation from manufacturer works to site, unloading and installation in tray & built in trench, testing at site and commissioning of 6.35 / 11 kV (E) grade, 3 Core X 400 Sq.mm, stranded compacted & circular Aluminium water tight conductor followed by semi conducting water swellable tape, conductor screen with Extruded semi conducting compound, Extruded WTR XLPE Insulated, Insulation screening with Extruded semi conducting compound, followed by water swellable semi conducting tape and single layer of copper tape(suitable to carry 1.12 kA/1 sec each core) and water swallable semi conducting tape, cores laid up with center filler, Extruded FRLSH PVC type ST-2 inner sheath followed by layer of poly Al. tape and HDPE type ST-7 intermediate sheath followed by single layer of Galvanized steel round wire armoured and overall Extruded FRLSH PVC type ST-2 sheathed cable generally conformes to IS 7098 part-2 and IEC 60502-2 with latest amendments and as per the tender specification. | 720 | Mtrs | - | - |
| 3 | Supply, installation, testing and commissioning of Raychem make 3 Core x 400 Sq. mm Heat Shrinkable Cable end Termination without gland for 3 Core Aluminium Conductor, 11 kV, XLPE insulated cables (indoor). (Refer Sec VI, Clause No.10.5). | 2 | Nos | - | - |
| 4 | Supply, installation, testing and commissioning of the Straight Through Joint (Crimping type) for 3 Core x 400 Sq. mm Raychem make Heat Shrinkable Cable Jointing Kits (Mechanical Connector type/Crimping type) Rayfit tubing for 3 Core Aluminium Conductor, 11 kV (E), XLPE insulated cables including excavation of soil, backfilling etc as specified.(Refer Sec VI, Clause No.10.6). | 2 | Nos | - | - |
| 5 | Supply, fabrication and installation of 50 mm X 6 mm size of Copper Flats in Built in trenches, on walls, poles, RCC Concrete and through embedded pipes as per the tender specification. (Refer Sec VI, Clause No.12.7). | 420 | Mtrs | - | - |
| 6 | Supply, fabrication and installation of the 50 mm X 6 mm size of Copper Flats in ground including excavation and refilling as per the tender specification. (Refer Sec VI, Clause No.12.7). | 370 | Mtrs | - | - |
| 7 | Cleaning of Indoor Substation Cable trenches and Motor area cable trench as directed by Engineer-in-Charge. Measurement will be per meter (length) basis of cable trench.(Refer Sec VI (MNC), Clause No.26). | 995 | Mtrs | - | - |
| 8 | Removal, shifting and reinstallation of complete Earth pit including Plate Earth Electrode, RCC Chamber and RCC cover slab with in 500 meter. Reinstallation shall be completed and tested as per IS: 3043 and as per Drawing No. IGC/ESD/5060/1001/1 enclosed. (50 Kg. each Bentonite & Charcoal shall be provided for each earth pit). (Refer Sec VI, Clause No.12.2). Scope include Excavation and refilling. | 10 | Nos | - | - |
| 9 | Supply, installation and testing of Copper Plate Earth Electrode as per IS: 3043 including Excavation, RCC Chamber and RCC cover slab as per Drawing Nos. IGC/ESD/5060/1001/1 & IGC/ESD/5060/1008/1 are enclosed. (50 Kg. each Bentonite & Charcoal shall be provided for each earth pit).(Refer Sec VI, Clause No.12.1 & 12.2). | 10 | Nos | - | - |
| 10Retrieval of the already laid one number 1100 Volts Grade XLPE/HRPVC insulated, Stranded Aluminium conductor cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of GI spacer, clamps etc and relaying the same cable in built-in trenches, on walls, poles and through embedded pipes using the retrieved spacer & clamp & supplying the shortage spacer & clamp if any as per the detailed specification. (Refer Sec VI, Clause No.7) | |||||
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.10 MB
Tenderdocument.pdf
Tender Documents • 2.08 MB
Additionaldocument_Annexure1GTP.pdf
Additional Documents • 0.36 MB
Additionaldocument_Annexure2QAP.pdf
Additional Documents • 0.43 MB
Additionaldocument_SEC -VI MNC.pdf
Additional Documents • 3.42 MB
Additionaldocument_Sec VI with drawings.pdf
Additional Documents • 14.25 MB
Additionaldocument_SectionV.pdf
Additional Documents • 0.76 MB
GCC2014.pdf
Additional Documents • 4.88 MB
BOQ_978545.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .