Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹1.5 CrAWARDED | ₹1.5 Cr | AWARDED |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
3 Jan 2026, 9:30 pmClosed
Karnataka Slum Development Board
Providing Energy Meters and streetlights to 210(G plus 1) houses constructed under JNNURM-BSUP Scheme in Arasu Colony Slum, Jayanagara Constituency, Banglore City.
KSDB/2025-26/EL/WORK_INDENT369
KSDB/2025-26/EL/WORK_INDENT369
Open
Electrical
Two Tender Document System(Two Cover)
KSDB Bengaluru Division No ONE
₹3,720
₹2.2 L
26 Dec 2025
26 Dec 2025
6 Jan 2026
3 Jan 2026
31 Dec 2025
Providing Energy Meters and streetlights to 210(G plus1) houses constructed under JNNURM-BSUP Scheme in Arasu Colony Slum, Jayanagara Constituency, Banglore City.
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. A) 16 Amps for Each House. For Panel Box. Complete as per Specifications and...
Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of sa...
Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting ,fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped wi...
Supplying.........A rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mountedonphenolic/ FRP/ DMC insulator whi...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. Complete as per Specifications and directions of Engineer in Charge
Supplying, fixing and wiring rotary selector switch suitable for Ammeter. Complete as per Specifications and directions of Engineer in Charge
Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc.,and fixing on existing wood or metal box using N. F. screws. Complete as per Specificatio...
Wiring for lighting/ power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I...
Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat......with bolts,washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. A) 50...
do above 75 x 75 x 6 mm
Supplying of on load change over switches 4poles, AC-23A Duty, 415V,50Hz, AC Supply. With all accessories.(SM Enclosure Sheet Metal Execution). 100A. Complete as per Specifications and directions of E...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 50 Sqmm...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable. 35 to 95 Sqmm. Complete as per Specifications and dir...
GI Pipes B-Class, 100mm dia. Complete as per Specifications and directions of Engineer in Charge
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5...
Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, la...
Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand). Complete as per Specifications and directions of Engineer in Charge
Cable Covering Tile 125x250x40 mm. Complete as per Specifications and directions of Engineer in Charge
Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water ...
LT AC Single Phase 2 Wire, 5-30 Amps Smart Energy Meter, Class 1.0 Accuracy with GPRS Communication Module. Complete as per Specifications and directions of Engineer in Charge
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyc...
Supplying and Fixing of........mm dia class A GI pipe bracket upto 2mtr long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / ...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Complete as per Specifications and ...
Three H Frame with Transformer Seating and Seating
angle support cross arm for 11 Mtr Spun Pole up to and
including 250 kVA (UG Cable)) - GI. Complete as per Specifications and directions of Engineer ...
Prefabricated Platform for erection of 250 kVA Transformer on 11 Mtr Spun Pole Structure involving Rectangular hollow Sections 96x48x4.87 Thk and 66x3x4.5 Thk, Circular hollow section of 165.6 OD x 10...
HT ST Support 50x8 mm Flat - MS. Complete as per Specifications and directions of Engineer in Charge
11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm
dia FRP Rod). Complete as per Specifications and directions of Engineer in Charge
Transparent Alkathine tube 19 mm dia, 2 mm thick in
coils of 30 Mtr. Complete as per Specifications and directions of Engineer in Charge
8 SWG GI Wire. (4.064 mm Dia), Std Wt: 131 Kg/KM. Complete as per Specifications and directions of Engineer in Charge
7/10 SWG Guy Wire. (7/3.251 mm Dia), Std Wt: 680 Kg/KM. Complete as per Specifications and directions of Engineer in Charge
GI Pipe 100mm dia. Complete as per Specifications and directions of Engineer in Charge
11 kV, HG Fuse Unit with Solid Core Insulator. Complete as per Specifications and directions of Engineer in Charge
11 kV, 200 Amps Single Break GOS. Complete as per Specifications and directions of Engineer in Charge
H - Frame Set for fixing 11 kV, 200 Amps Single Break
GOS - (For DP structure for providing New GOS for
sectionalisation) - MS. Complete as per Specifications and directions of Engineer in Charge
GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg. Complete as per Specifications and directions of En...
Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. Complete as per Specifications and directions of Engineer in Charge
Good Quality Salt for grounding purposes packed in 50
Kg gunny bag. Complete as per Specifications and directions of Engineer in Charge
9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR. Complete as per Specifications and directions of Engineer in Charge
PVC Insulation Tapes 19 mm wide and in rolls of 10 Mtr. Complete as per Specifications and directions of Engineer in Charge
11 kV, Horizontal Cross Arm - Mild Steel (MS). Complete as per Specifications and directions of Engineer in Charge
MS Fish Plate. Complete as per Specifications and directions of Engineer in Charge
Caution/Danger Board. Complete as per Specifications and directions of Engineer in Charge
Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014. 250 kVA, Aluminium Wdg, Star 2 (5 Star). Complete as per Specifications and directions of Engi...
LT Distribution Box for 250 kVA DTC with MCCB's (Sheet Metal). Complete as per Specifications and directions of Engineer in Charge
LT Distribution Box for 100/250 kVA DTC with MCCB's
(SMC). Complete as per Specifications and directions of Engineer in Charge
LT 3 Phase 4 Wire 5-30 Amps Thread Through Type composite Meter Housing Box consisting of ETV Meter with AMR comply and LTCT with built in GSM/GPRS Modem (as per technical specification) upto 100 kVA ...
LT Metering Box for housing the ETV Meter without
CT's busbar wiring etc. Complete as per Specifications and directions of Engineer in Charge
CT Ratio - 50/5A, 0.5 Accuracy Class. Complete as per Specifications and directions of Engineer in Charge
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. Complete as per Specifications and directions of Engineer in ...
Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL. Complete as per Specifications and directions of Engineer in Charge
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
GI pipe 100 mm (Nominal bore), medium class
(including accessories). Complete as per Specifications and directions of Engineer in Charge
Digging of Pit 2.5 Mtr depth for erection of 11 Mtr long Tubular Spun Pole as per approved Drawing. Hard Soil. Complete as per Specifications and directions of Engineer in Charge
Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr
depth (Mechnised Labour). Complete as per Specifications and directions of Engineer in Charge
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc.,complete for mounting of Transforme...
For Three H Frame with Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA (UG Cable) (excluding erection of Pole). Complete as per Specifications ...
Fixing of HT/LT Single Top Support. Complete as per Specifications and directions of Engineer in Charge
Erection of 200 - 250 kVA Transformer. Complete as per Specifications and directions of Engineer in Charge
Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC. 250 kVA TC. Complete as per Specifications and directions of Engineer in Charge
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross
arm and wiring. Complete as per Specifications and directions of Engineer in Charge
Fixing of GOS including wiring (11 kV Single Break 200 Amps). Complete as per Specifications and directions of Engineer in Charge
Fixing of 3 Nos Lightning Arrestor including wiring. Complete as per Specifications and directions of Engineer in Charge
Fixing of LT Metering Box with clamping arrangement for
mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the...
Wiring of 2 Circuits of LT Wiring for for 25/63/100 kVA DTC
to the existing LT protection Kit/Distribution Box via metering
box. (includes fixing of necessary supports like 2 Pin cross
arm, Spacer etc...
Loading of Transformer (when maintaince men for loading and unloading are not available in store). 250/300 kVA. Complete as per Specifications and directions of Engineer in Charge
Unloading of Transformer (when maintaince men for loading and unloading are not available in store). 250/300 kVA. Complete as per Specifications and directions of Engineer in Charge
Erection of H-Frame. Complete as per Specifications and directions of Engineer in Charge
Providing GI Pipe Earthing for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding digging of pits). Complete as per Specifications and directions of Engineer in Charge
Initial Security Deposit
Meter Security Deposit
Single Phase Energy Meter
Service Charges
Registration charges
Power Supply Agreement Charges
Registration charges
Power Supply Agreement Charges
Name Transfer Indemnity Bond
Application, CR Test Report Drawing
Name transfer Service Charges
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .