Directorate of Municipal Administration
Shanthakumar JE
Construction of Proposed 12TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) in SWM Site in Sindhanur Municipal Limit.
DMA/2024-25/BD/WORK_INDENT25868
DMA/2024-25/BD/WORK_INDENT25868
Open
Buildings
Two Tender Document System(Two Cover)
DMA City Municipal Council Sindhanuru
6 documents required · 6 mandatory
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. 42.33 (50% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete -145.49 cum, TMT Stee 7293.04 Kgs, Structural Steel work 14800.00 Kgs and Galvanised iron profile sheets 1298.81 Sqm, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. 2.01 (not less than 50% of electrical works) n any one year
PWD Contractor Registration Certificate
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 169.32Lakhs)
Liquid assets and /or availability of credit facilities of no less than Rs. 25.40 Lakhs (estimated cash flow for 3 months of peak construction period)
Banker Details for reference
GST Registration Certificate
₹1,800
₹1.7 L
12 Aug 2024
12 Aug 2024
21 Aug 2024
19 Aug 2024
Construction of Proposed 12TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) in SWM Site in Sindhanur Municipal Limit.
KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricad...
KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as p...
KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coar...
KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking...
KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) .
KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site...
KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conf...
KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffo...
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of appro...
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/...
KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth comp...
KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including apply...
KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including apply...
KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, ...
KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifica...
KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approv...
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture includ...
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overlo...
Three Pole- 100 A 25 kA
Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA
Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 63 A TP
Supplying of 100A 4x30x6mm Aluminium Strips rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic...
Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat 40x40x6mm with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.
Fabricating supplying and mounting MS box made out 14 SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with...
Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947
Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.
Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring...
Supplying and fixing of metal clad industrial plugs and sockets.
Supplying and fixing of metal clad industrial plugs and sockets. 16 Amps
Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter
Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board
Supplying,fixing and wiring rotary selector switch suitable for Ammeter.
Supplying, fixing and wiring rotary selector switch suitable for Voltmeter
Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound
Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomple...
Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5Cx5...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 4Cx25 ...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 4Cx16 ...
Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights,...
Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations
Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixi...
Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixi...
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-...
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-...
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-...
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-...
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-...
Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I...
Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I...
Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I...
Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I...
Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified I...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing met...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing met...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF ...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF ...
Supply & fixing of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection mould...
Earthing GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip
2 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required
Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be fill...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW-3 bid_document-25868.doc
Tender Document • 1.43 MB
KGV-Q67SZW-10TPD-ST-01-Primary & Secondary Shed.pdf
Design Document • 0.64 MB
KGV-Q67SZW-10TPD-ST-01-Primary Shed.pdf
Design Document • 0.62 MB
KGV-Q67SZW-10TPD-ST-02-Primary & Secondary Shed.pdf
Design Document • 0.72 MB
KGV-Q67SZW-10TPD-ST-02-Primary Shed.pdf
Design Document • 0.67 MB
KGV-Q67SZW-10TPD-ST-03-Primary & Secondary Shed.pdf
Design Document • 0.57 MB
KGV-Q67SZW-10TPD-ST-03-Primary Shed.pdf
Design Document • 0.55 MB
KGV-Q67SZW-10TPD-ST-04-Primary & Secondary Shed.pdf
Design Document • 1.51 MB
KGV-Q67SZW-10TPD-ST-04-Primary Shed.pdf
Design Document • 1.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .