Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹40.0 L+₹2.1 L (5.58%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹40.8 L+₹2.9 L (7.72%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
2 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR AND MAINT OF LT DISTRIBUTION SYSTEM, OVER HEAD LINES, CABLES, CHANGE OVER PANELS, CONTROL SWITCHES AND CONNECTED ITEMS AT INS UTKROSH AND VAYU VIHAR BROOKSHABAD UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2021_MES_465021_1
8968/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹98,000
Yes
29 Oct 2021
4 Aug 2021
10 Sept 2021
4 Aug 2021
2 Sept 2021
20 Aug 2021
60 days
Amount
Excavation in soft / loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
Excavation in soft / loose soil n.exc 1.5 mtr wide and exc 1.5 mtr depth and n.exc 3.0 mtr and getting out all as specified and directed
Excavation in hard / dense soil Iincluding n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
Returning filling using excavated soil including spreading levelling, watering and well ramming in layers n.exc 25 cms all as specified and directed
Removal of surplus excavated soil n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point complete all as specified and directed
S & F in replacement of on load change over switch 415 V, 4 pole, 100 A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of on load change over switch 415 V, 4 pole, 125 A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of on load change over switch 415 V, 4 pole, 160 A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement on load change over switch 415 V, 4 pole, 200 A open execution as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of on load change over switch 415 V, 4 pole, 250 A open execution as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of on load changeover switch 415 V, 4 pole, 320A open execution as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of on load changeover switch 415 V, 4 pole, 400A open execution as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63 A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100 A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 160A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 200A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 250A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 320A as per existing make and model or suitable equivalent make as per list of make at PS complete all as specified and directed.
S&F in replacement of MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 400A as per existing make and model suitable or equivalent make as per list of make at PS complete all as specified and directed.
M&L for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable and making joints suitalbe for aluminium conductor of following size :- Note : Taking up / down the fault cable, excavation, returning filling, removal of surplus soil shall be measured and paid separately under relevant item of this schedule.
16 to 25 Sqmm 3.5 core
35 to 70 Sqmm 3.5 core
95 to 150 Sqmm 3.5 core
185 to 240 Sqmm 3.5 core
300 to 40 Sqmm 3.5 core
Supply and laying in replacement of GI tubing light grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size all as specified and directed:-
100mm dia
80mm dia
50mm dia
40mm dia
S&F in replacement of aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
S&F in replacement of galvanised iron strip 32 x 6 mm burried in ground all as specified and directed.
S&F in replacement of air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.
S&F in replacement of test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm drilled and screwed with 3 Nos 8mm dia, 25mm long hexagonal head screw all as specified and directed.
Taking up/down old unserviciable LT UG cables from trench/poles/wall etc of following size all as specified and directed:-
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply and laying of LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes all as specified and directed :-
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement of DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc.with smooth internal and profiled external surface for non pressure under ground cable complete all as secified and directed
All as per item No 29.00 above but outer dia of 63 mm and inner dia 50 mm.
All as per item No 29.00 above but outer dia of 77 mm and inner dia 63 mm.
All as per item No 29.00 above but outer dia of 90 mm and inner dia 76 mm .
All as per item No 29.00 above but outer dia of 110 mm and inner dia 95 mm.
All as per item No 29.00 above but outer dia of 120 mm and inner dia 103.5 mm.
All as per item No 29.00 above but outer dia of 160mm and inner dia 126 mm.
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mir deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I.Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
S & F in replacement of digital soft starter suaitable for 15 HP submersible pump removing existing un serviceable starter and fixing new with proper electrical connection including additional wiring etc complete all as specified and directed.
S & F in replacement of star delta starter suaitable for 10 to 12.5 HP submersible pump with proper electrical connection including additional wiring etc complete all as specified and directed.
M & L for grass cutting with Petrol Grass Cutting machine all around the E/M installations at INS Utkrosh area.
S&F in repairs aluminium cables lugs for cables of size upto 10 Sqmm including necessary crimping with crimping tool complete all as specified and directed
All as per item No 40.00 above but for cable of size upto 16 Sqmm
All as per item No 40.00 above but for cable of size upto 25 Sqmm
All as per item No 40.00 above but for cable of size upto 35 Sqmm
All as per item No 40.00 above but for cable of size upto 50 Sqmmm
All as per item No 40.00 above but for cable of size upto 70 Sqmmm
All as per item No 40.00 above but for cable of size upto 95 Sqmmm
All as per item No 40.00 above but for cable of size upto 125 Sqmmm
All as per item No 40.00 above but for cable of size upto 185 Sqmmm
All as per item No 40.00 above but for cable of size upto 240 Sqmmm
All as per item No 40.00 above but for cable of size upto 300 Sqmmm
All as per item No 40.00 above but copper lugs of size upto 25 Sqmm
All as per item No 40.00 above but copper lugs of size upto 35 Sqmm
All as per item No 40.00 above but copper lugs of size upto 50 Sqmm
All as per item No 40.00 above but copper lugs of size upto 70 Sqmm
M & L for LT Panel board outdoor type repair/replace damged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting,welding driling hole etc.works required at site including taking down old u/s complete all as specified and directed
M&L for providing cement concrete Type B1 1:2:4 using 20mm graded stone aggregate as in hard standing after laying cable under road etc all as specified and directed.
Design, Supply, installing testing and commissioning factory fabricated in door type (CPRI Approved) totally enclosed LT cubical panel board suitable size 600 Amps bus bar connected with 2 Nos of contactor and interlinked both for connecting 2 nos of DG set out put supply to the busbar and one No of MCCB to be fitted in Panel for out put supply conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement,including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge.including Supply and fixing the following :-
Design, Supply, installing testing and commissioning factory fabricated In door type totally enclosed LT cubical panel board suitable size with busbar, conforming to relevant IS and protection class IP-65 ,dust,vermin and weather proof fabricated out of 3.15mm thick CRCA sheet duly powder coated ,mounted on 40x40x5mm MS angle iron frame,duly welded in shape and coated with two coats of synthetic enamel paint of approved colour over a coat of redoxide primer including necessary grouting of legs 300mm deep in ground in PCC 1:4:8 type D2 using 40mm graded stone aggregate ,panel base to be 500mm above ground level with suitable compartments for controls and Monitors including cable glands for incoming and outgoing cables,locking arrangement,including accomodating, supply and fixing the following accessories/items including necessary internal panel wiring with suitable size of Copper wire PVC insulated & sheathed multi stranded complete all as specified and as directed by Engr-in-charge.including Supply and fixing the following :-
Finding out cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with advance accurate fault detector machine complete all as specified and as directed. Note : If the fault detection found incorrect, the contractor shall redo the job and making good the disturbed surface in all respect at his own cost, no claim shall be entertained in this regard.
S&F in replacement of heavy duty resin filled capacitor 440 volt, 3 Ph of capacity upto 30 KVAR including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of APFC Controller upto 5 Step including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of digital Volt meter (0-500) including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of digital ammeter including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of Indicating Lamp R. Y. B (LED) type including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of CTs of required rating including connections and testing for proper functioning complete all as specified and directed.
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:- (a) S & F copper bus bar 300 Amp with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) S&F MCCB FP 200 Amps 25 KA - 01 No
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following:-(a) S & F copper bus bar 400 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) S&F MCCB FP 250 Amps 35 KA - 01 No
S&F pole cap made out of MS including one coat of aluminium paint over two coats of red oxide primer paint suitable for 8.5 / 9.0/ 11.0 mtr long tubular pole including threaded hole 3 Nos and suitable size of nut and bolts complete all as specified and directed.
M &L for painting to existing steel tubular poles 9 mtr long including cross arms etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number complete all as directed.
M&L for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coats of grey or any colour as approved by GE / Engr in -Charge as per site suitability synthetic enamel paint including door welding with hinges complete as specified and directed
Attending breakdown for LT Panels/ LT Cables/ MCCB /Change over Switch to check and locate / detect fault related to breakdown complete all as directed by Engineer-in-charge. Note:- (a) Minor spares shall be inclusive of qouted rate (b) The break down complaint should be attended within 2 hours on receiving intimation form Engr-in-charge or concern JE E/M by telephonically / verbally. (c) Not attending of complaint within two hours will lead to recovery from subsequent payment in the following manner :- (i) Not attending within 2 to 4 Hours - Rs. 2000.00 (ii) Not attending within 4 to 6 Hours- Rs. 4000.00 (iii) Not attending within 6 to 8 Hours- Rs. 8000.00 (iv) Not attending after 8 Hours - Rs. 10,000.00 (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means.
M&L for Notice board 6 feet by 4 feet using 0.5 mm thick foam sheet including writing of DG set/transformer/AC plant/Pumps details as per given format and shall be print in blue color only and letters are white color minimum 76 leters and maximum 90 leters and fixing with revit r screw including taking down old existing board from site , before make a board demo copy shall be collect from site JE E/M with details all as specified and as directed
M&L for Notice board 4 feet by 3 feet using 0.5 mm thick foam sheet including writing of particular deatils of E/M installations and shall be print in blue color only and letters are white color minimum 50 leters and maximum 70 leters and fixing with revit screw including taking down old existing board from site , before make a board demo copy shall be collect from site JE E/M with details all as specified and as directed
Supply and errect in position steel tubular swaged poles complete with cast iron base plate ,finial taper plug,bolts,nuts & screws as specified type 410 SP-31(9.00 metres long) all as specified and as directed.
M & L for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and as directed.
M & L for plain cement concrete 1:3:5 type C1 using 20 mm graded stone aggregate for poles complete all as specified and as directed.
A. R. ELECTRICALS
AMR TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .