Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 CrAccepted-AOC | ₹34.4 Cr Quoted ₹34.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹34.4 CrRejected-Finance | ₹34.4 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹36.1 CrRejected-Finance | ₹36.1 Cr | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical MULUND | AHMEDNAGAR | MAHARASHTRA | 413201 | - | - | Rejected-Technical Disqualified |
Tender Value
₹30.8 Cr
EMD Value
₹15.4 L
Closing Date
9 Aug 2021, 4:00 pmClosed
Executive Engineer
TMC Thane Arunkumar Vaidya Marg. Gen Panchpakhadi Thane West.
Construction of Transit Building on Amenity Plot near Kores road under Cluster Development plan in Thane
2021_TMC_704971_1
TMC/PRO/PWD-HQ/334/2020-21
Open Tender
Civil Works - Buildings
730 days
TMC Thane
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
₹15.4 L
TMC Thane
11 Feb 2022
16 Jul 2021
10 Aug 2021
16 Jul 2021
9 Aug 2021
16 Jul 2021
3 Aug 2021
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means SSR. 20-21 BDA-1 SR. NO.1813 It. N0 21.01
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means SSR. 20-21 BDA-4 SR. NO.724 It. N0 21.16 c)1.50m to 3.00m lift, Add 20%
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical Means SSR. 20-21 BDA-4 SR. NO.728 It. N0 21.20 d) 4.00m to 5.0m lift, Add 30%
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) SSR. 20-21 BR4B SR. NO.417 It. N0 12.23
Collecting, filling in trucks, Carting away and disposal of unsuitable soil/ debries genrated on site up to any lead including loading, unloading complete. 5K.M
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. SSR. 20-21 Bd.A 11 SR. NO.744 It. N0 21.37
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. Complete. SSR. 20-21 Bd.F 11 SR. NO.836 It. N0 21.38
Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR. 20-21 Bd.E-1 SR. NO.820 It. N0 24.01 M:15 using 20 mm and down aggregate (150mm THK) for footing
M:15 using 20 mm and down aggregate (100mm THK) at plinth level
M-15 For Compound Wall
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR. 20-21 Bd.F 11 SR. NO.831 It. N0 25.19
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCAD Aenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR. 20-21 Bd.F 11 SR. NO.837 It. N0 25.39 RCC with grade M:40 for Columns Below Ground Columns
Ground Floor Columns
1st Floor Columns
2nd Floor Columns
3rd Floor Columns
4th Floor Columns
5th Floor Columns
RCC with grade M:35 for Columns 25.37 6th Floor Columns
7th Floor Columns
8th Floor Columns
9th Floor Columns
10th Floor Columns
RCC with grade M:30 for Columns 25.35 11th Floor Columns
12th Floor Columns
13th Floor Columns
14th Floor Columns
15th Floor Columns
16th Floor Columns
17th Floor Columns
18th Floor Columns
19th Floor Columns
20th Floor Columns
21st Floor Columns
Terrace Level Columns
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR. 20-21 Bd.F 6 SR. NO.841 It. N0 25.54 RCC with grade M:30 for Plinth Beams and such.
RCC with grade M:30 for Beams and such. 1st Floor Beams
2nd Floor Beams
3rd Floor Beams
4th Floor Beams
5th Floor Beams
6th Floor Beams
7th Floor Beams
8th Floor Beams
9th Floor Beams
10th Floor Beams
11th Floor Beams
12th Floor Beams
13th Floor Beams
14th Floor Beams
15th Floor Beams
16th Floor Beams
17th Floor Beams
18th Floor Beams
19th Floor Beams
20th Floor Beams
21st Floor Beams
Terrace Level Beams
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR. 20-21 Bd.F 6 SR. NO.848 It. N0 25.74 Slab,Staircase etc. RCC with grade M:30 for Slab and such. 1st Floor Slab,Staircase
2nd Floor Slab,Staircase
3rd Floor Slab,Staircase
4th Floor Slab,Staircase
5th Floor Slab,Staircase
6th Floor Slab,Staircase
7th Floor Slab,Staircase
8th Floor Slab,Staircase
9th Floor Slab,Staircase
10th Floor Slab,Staircase
11th Floor Slab,Staircase
12th Floor Slab,Staircase
13th Floor Slab,Staircase
14th Floor Slab,Staircase
15th Floor Slab,Staircase
16th Floor Slab,Staircase
17th Floor Slab,Staircase
18th Floor Slab,Staircase
19th Floor Slab,Staircase
20th Floor Slab,Staircase
21st Floor Slab,Staircase
Terrace Level Slab,Staircase
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR. 20-21 Bd.F 12 SR. NO.855 It. N0 26.19 OHT,LMR RCC with grade M:30
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Footing
Plinth
First Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
22 Floor SSR. 20-21 Bd.F 17 SR. NO.864 It. N0 26.33
Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. SSR. 20-21 BDH1 SR. NO. 897 It. N0 28.01
Providing coursed rubble masonry first sort of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in superstructure including racking out joints on the inside when plastering is to be done, watering and scaffolding etc. complete. SSR. 20-21 BDH14 SR. NO. 908 It. N0 28.12
Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. Complete. SSR. 20-21 BDG5 SR. NO. 885 It. N0 32.18
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete Ground Floor
First Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
22 Floor
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete SSR. 20-21 BDL16 SR. NO. 962 It. N0 27.05
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. Complete. ( 1165.50 X 21% = 244.75 + 1165.50 =1410.25 )
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. SSR. 20-21 BDJ SR. NO. 934 It. N0 31.05 First Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21Floor
Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. SSR. 20-21 BDJ SR. NO. 936 It. N0 31.07 First Floor ( 1.95 + 1.20 ) 2 = 6.30
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor ( 1.95 + 1.20 ) 2 = 6.30
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 Hrs. by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. SSR. 20-21 BDJ SR. NO. 947 It. N0 31.26 First Floor ( 1.95 + 1.20 ) 2 = 6.30
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor ( 1.95 + 1.20 ) 2 = 6.30
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. SSR. 20-21 BDJ SR. NO. 948 It. N0 32.01 Ground Floor
First Floor ( 1.95 + 1.20 ) 2 = 6.30
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor ( 1.95 + 1.20 ) 2 = 6.30
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. SSR. 20-21 BDJ SR. NO. 950 It. N0 32.03 Ground Floor
First Floor ( 1.95 + 1.20 ) 2 = 6.30
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor ( 1.95 + 1.20 ) 2 = 6.30
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. SSR. 20-21 BDLSR. NO. 975 It. N0 32.31 Ground Floor First Floor ( 1.95 + 1.20 ) 2 = 6.30
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor ( 1.95 + 1.20 ) 2 = 6.30
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. SSR. 20-21 BDJ SR. NO.956 It. N0 32.11 Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Six Floor
Seventh Floor
Eight Floor
Ninth Floor
Tenth Floor
Eleven Floor
Tweleth Floor
Thirteen
Fourteen
Fifteenth Floor
Sixteenth Floor
Seventeenth Floor
Eighteenth Floor
Nineteenth Floor
Twenty Floor
Twenty First Floor
Terrace Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. SSR. 20-21 Bd.M.22 Page Number 390 It. N0 33.18 Ground Floor
1 Floor
2Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. SSR. 20-21 BDJ SR. NO. 1024 It. N0 33.24 Gr. Floor
1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Bd.M.13 Page Number 386. 33.25 1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. SSR. 20-21 BDJ SR. NO. 1022 It. N0 33.24 First Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. SSR. 20-21 BDJ SR. NO. 1022 It. N0 33.27 First Floor ( 1.95 + 1.20 ) 2 = 6.30
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor ( 1.95 + 1.20 ) 2 = 6.30
Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, moulding edges, cleaning complete. a) Marble other than white makrana SSR. 20-21 BDJ SR. NO. 1045 It. N0 33.21 Gr. Floor
1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary SSR. 20-21 BDO SR. NO. 1088 It. N0 35.26 Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Six Floor
Seventh Floor
Eight Floor
Ninth Floor
Tenth Floor
Eleven Floor
Tweleth Floor
Thirteen
Fourteen
Fifteenth Floor
Sixteenth Floor
Seventeenth Floor
Eighteenth Floor
Nineteenth Floor
Twenty Floor
Twenty First Floor
Terrace Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. SSR. 20-21 BDP SR. NO. 1083 It. N0 35.21 Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Six Floor
Seventh Floor
Eight Floor
Ninth Floor
Tenth Floor
Eleven Floor
Tweleth Floor
Thirteen
Fourteen
Fifteenth Floor
Sixteenth Floor
Seventeenth Floor
Eighteenth Floor
Nineteenth Floor
Twenty Floor
Twenty First Floor
Terrace Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat)etc. complete. SSR. 20-21 BDP SR. NO. 1100 It. N0 36.12 1 Floor
2Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete SSR. 20-21 BDJ SR. NO. 1186 It. N0 39.01 Gr. Floor
1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Terrace Floor
Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. SSR. 20-21 Bd.T 11 SR. NO.1234 It. N039.48 Gr. Floor
1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Terrace Floor
Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. SSR. 20-21 Bd.T 34 SR. NO.1194 It. N039.10 1
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating without box SSR. 20-21 BDT SR. NO. 1226 It. N0 39.40 Gr. Floor
1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box SSR. 20-21 BDT SR. NO. 1226 It. N0 39.44 Gr. Floor
1Floor
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. SSR. 20-21 BDP SR. NO. 1257 It. N0 39.68 Floor 1
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.No.: As directed by Engineer- in-charge. For Compound Wall
Providing and fixing 15mm diameter concussion push button type brass/gun metal self- closing tap including necessary socket complete.
Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete.
Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete.
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram)
Providing and making ISI Mark ferrule connection of 50 mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight with 75 mm thick R.C.C. cover medium duty 140Kilogrametc. complete.
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.
Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Providing and laying for 225mm dia. salt glazed S.W. Pipe including fitting such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete
Providing and fixing 30mm thick PVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 mm MS tubes inserted horizontally inside the hollow profile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thick x 20 mm width on stiles and rails using solvent cement. The inner panel shall be laminated with 5mm thick termite proof waterproof plain /prelam PVC sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. Floor 1
2 Floor
3 Floor
4 Floor
5 Floor
6 Floor
7 Floor
8 Floor
9 Floor
10 Floor
11 Floor
12 Floor
13 Floor
14 Floor
15 Floor
16 Floor
17 Floor
18 Floor
19Floor
20 Floor
21 Floor
Electrical Work Electrification of internal flat wiring, Point wiring for light/fan/bell concealed type in min 20 mm mISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
Supplying and erecting gong with double coil suitable for 230V complete erected on polished wooden block.
Point wiring for independent plug in ISI mark HMS PVC conduit with 1.5 sq.mm (2+1E )FR LSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW( for Geyser)
Point wiring for independent plug in ISI mark HMS PVC conduit with 1.5 sq.mm (2+1E )FR LSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW( for Oven Fridge)
Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW.( Utility Point)
Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB
Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete.
Supplying erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board complete
Supplying & erecting mains with 3x4 sq.mm. and earth wire 2.5 sq.mm FR PVC copper wire in HMS PVC conduit min.20mm dia, as per specification No: WG-MA/PC.
Supplying & erecting mains with 2x1.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 20mm dia as per specification No: WG-MA/PC.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 ways for incoming and 10 ways for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB
Supplying, fixing and commissioning 2 pole,RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SWRCCB/RCBO
Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying and erecting broadband splitter unit with 1 input & 2 output RJ 11 female connectors complete.
Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting Five star rated energy saving Ceiling fan 230 V A.C 50 cycles 1200 mm. sweep complete erected in position as per specifcation no. FG-FN/CF
Supplying and erecting Fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying & erecting 10-12W, 230V integral type LED Lampsuitable for B-22/E-27 base.
Electrification of Common area Point wiring for light/fan/bell concealed type in min 20 mm mISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying & erecting mains with 2x1.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 20mm dia as per specification No: WG-MA/PC.
Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Point wiring for independent plug in ISI mark HMS PVC conduit with 1.5 sq.mm (2+1E )FR LSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/S
Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW.( Utility Point)
Supplying & erecting mains 2x1.5 sq.mm. and earth wire 1.5 sq.mm FR PVC copper wire, ISI mark HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC.
Supplying & erecting mains with 2x1.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire, in HMS PVC conduit min. 20mm dia as per specification No: WG-MA/PC.
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 16 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Z Patti , zinc plated perforated type mounting of size 50x 30 for conduits supports in shafts
corrosion resistive, 18 guage Galvanised steel metal junction box (Size - 200mm length X 200mm width X 50mm) concealed into lift lobby slab for pulling of wires between shaft & flats. Thickness of sheet steel shall be 2mm.
Supplying and erecting decorative oval bulk head edge-lit 10W LED luminaire comprising of high brightness LED Fitting on provided PVC block / wooden board.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supply Installation Testing & commissioning of Integral high pressure Die cast/extruded aluminum LED Streetlight luminary the system wattage (fixture's total power consumption)should be 60 Watt. Details as per technical specification attached.
Supplying and erecting Street light bracket made from 40 mm.dia ‘B’ class G.I. Pipe, 0.6m. in length, PU painted in silver colour,suitable for wall mounting of fitings with provided leads as per specification no. FG-BKT/BPC
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded Earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. with FRP chamber having Cover size of min.200mm x200mm at top and 300x300mm at bottom and at least 150mm in height. It should must be tested in Govt of India’s National Test House for load carrying capacity of min. 6000Kg. (6T). The rate shall inclusive of all masonary work required for complete the work. Specification no. EA-MOBI
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
Supply,installation,testing and commissioning of 50x10 mm GI equipotential bar of 300 mm length with suitable support arrangement to conect earthing strips from earth pit as well as cable going for equipment earthing
Supply,installation,testing and commissioning of 25x6 mm GI equipotential bar of 300 mm length with suitable support arrangement to conect earthing strips from earth pit as well as cable going for flat earthing
Supply,installation,testing and commissioning of A) Common Services panel: Incomer - 400A FP MCCB- 36KA - 2 NO,Metering - Multifunction Meter - 1no, outgoing- 6/10/16 A FP MCB - 15 Nos, 32/40 A FP MCB - 6 No,63A FP MCB - 4 Nos B) Lift power panel:- Incomer - 100A FP MCCB- 25KA - 2 NO, Metering - Multifunction Meter - 1no, outgoing- 6/10/16 A FP MCB - 04 Nos, 32/40 A FP MCB - 1 No, 63 A FP RCCB 300mA - 1 No C) Fire Lift Power Panel as Per Specification, Technical data Sheet, complete in all respect . As directed by Engineer incharge
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP /TP MCBs of 12 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6 A to 32 A B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (forlighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying, fixing and commissioning 2 pole RCBO (residualcurrent breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SW-RCCB/RCBO
Supplying and erecting broadband splitter unit with 1 input & 2 output RJ 11 female connectors complete.
Supplying & installing co-axial copper cable low voltage grade RG-6 as per specification No. WG-TW
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner
Providing and fixing of test link in weather proof 1.6 mm thick MS box of approved make & design
Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EAEP.
Supplying and erecting marine plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 300A complete as per specification no. CP-BB
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 400A complete as per specification no. CP-BB
Providing & erecting 4 Pole MCCB of 250A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing and Fixing of CRCA sheet 2mm (14 gauge) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetting etc. without painting
Providing powder coating of approved color shade on both sides of provided iron work / MS /CRCA sheet steel work complete including antirust treatment in an approved manner.
Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
SITC of Lifts at Transit camp building SITC of Electric Traction Passenger Lift , Mx gearless Machine unit with • Rated capacity :- 15 Passenger cum Stretcher Lift • Floors :- G+21 floor (22 Stops/22 Landings) • Location of Lift Machine:- MR/MRL • Rated speed :- 1.5mp, Car emergency light with hand rails mirrors, Cabin fan with auto cutoff, fireman drive, curtian of light 169 beams, accurate relevelling, automatic closed door, manual rescue operation, automatic break testing after every 11 hrs., segmented LCD display in COP, correction drive to next level, car door lock, bypass load function, Overload function, main power failure and rescue announcer, correction drive to next level, door close/open button, opration of car ventilation inpulse and automatic operation of car light, emergency intercom car MAP, LED spot light, ARD complete with neccessory SMF VRLA batarries, Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/ frames, with VVVF drive, Job includes all civil works for irrection of lift in lift duct, complete in all respect. MAKE: M/s. Schindler India Pvt. Ltd, M/s Kone Elevators, M/s Johnsons Elevators, M/s Otis
SITC of Electric Traction Passenger Lift , Mx gearless Machine unit with • Rated capacity :- 8 Passenger cum Stretcher Lift • Floors :- G+21 floor (22 Stops/22 Landings) • Location of Lift Machine:- MR/MRL • Rated speed :- 1.5mp, Car emergency light with hand rails mirrors, Cabin fan with auto cutoff, fireman drive, curtian of light 169 beams, accurate relevelling, automatic closed door, manual rescue operation, automatic break testing after every 11 hrs., segmented LCD display in COP, correction drive to next level, car door lock, bypass load function, Overload function, main power failure and rescue announcer, correction drive to next level, door close/open button, opration of car ventilation inpulse and automatic operation of car light, emergency intercom car MAP, LED spot light, ARD complete with neccessory SMF VRLA batarries, Doors with frame having clear opening of 700 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door rchitraves/frames, with VVVF drive, Job includes all civil works for irrection of lift in lift duct, complete in all respect. MAKE: M/s. Schindler India Pvt. Ltd, M/s Kone Elevators, M/s Johnsons Elevators, M/s Otis.
Vaishnav Construction
A E infra projects pvt ltd
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid