Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-Finance | ₹2.6 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹2.6 CrRejected-Finance | ₹2.6 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹2.9 CrRejected-Finance GULALI VATIKA GEETA VATIKA SHAHPUR DISTRICT GORAKHPUR | ₹2.9 Cr | L3 | Rejected-Finance L3 |
| 4 | L4₹2.9 CrRejected-Finance VILLAGE AND POST PIPRA GAUTAM TEHSIL AND DISTRICT BASTI UTTAR PRADESH | GONDA | UTTAR PRADESH | 271305 | ₹2.9 Cr | L4 | Rejected-Finance L4 |
| 5 | L5₹3.1 CrRejected-Finance D 39 DIVYA NAGAR GORAKHPUR | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | ₹3.1 Cr | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | M/S ADITYA CONSTRUCTION COMPANY L4 | M/S VISHAL CONSTRUCTION L3 | M/s AJAY KUMAR SAHI L2 | M/S ASHISH KUMAR PANDEY L1 | M/S SHUBHAM CONSTRUCTION L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavaton work in excavation. Dry Earthwork in foundation building work including lead up to 30M and lift upto 1.5M and its disposal. As directed by Engineer-in charge. All kinds of soil | 589.2 | CUM | 84.99 ₹50,076.11 | 84 ₹49,492.80 | 81 ₹47,725.20 | 70 ₹41,244 | 90 ₹53,028 |
| 2.00 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 70.00 Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distance of 50m out side the periphery of area cleared. under floor Local Sand. | 23.87 | CUM | 1,868.2 ₹44,593.93 | 1,859 ₹44,374.33 | 1,550 ₹36,998.50 | 1,200 ₹28,644 | 1,978.4 ₹47,224.41 |
| 3.00 | Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering.
Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P.
(b) mechanical mixing + Labour cost.(M15) (1:2:4) | 32.52 | CUM | 9,531.7 ₹3.1 L | 9,488 ₹3.1 L | 8,800 ₹2.9 L | 7,000 ₹2.3 L | 9,000 ₹2.9 L |
| 4.00 | Cement concrete with stone grit in RCC work excluding all cost of material but inclusive of labour and T&P and also excluding centering, shuttering and reinforcement.
(b) mechanical mixing and Extra for mechanical vibration with 1% water charges.
Total Concrete work for structure. (M25) (1:1:2) | 366.69 | CUM | 11,463.67 ₹42.0 L | 11,411 ₹41.8 L | 10,500 ₹38.5 L | 8,800 ₹32.3 L | 12,139.86 ₹44.5 L |
| 5.00 | Thermo-Mechanically Treated bars work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. | 303.8 | QUINTELS | 6,351.99 ₹19.3 L | 6,323 ₹19.2 L | 6,480 ₹19.7 L | 6,500 ₹19.7 L | 6,726.67 ₹20.4 L |
| 6.00 | Backfilling the footings, Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty.
Upto 10 km extra lead. | 350.13 | CUM | 307.61 ₹1.1 L | 306 ₹1.1 L | 292 ₹1.0 L | 270 ₹94,535.10 | 325.75 ₹1.1 L |
| 7.00Centering and shuttering including strutting, propping etc. and removal of form for | ||||||||
| 7.01 | Foundations, footings, bases of columns, etc. for mass concrete | 318.84 | SQM | 282.54 ₹90,085.05 | 281 ₹89,594.04 | 269 ₹85,767.96 | 200 ₹63,768 | 299.21 ₹95,400.12 |
| 7.02 | Suspended floors, roofs, landings, balconies and access platform. | 970.95 | SQM | 668.08 ₹6.5 L | 665 ₹6.5 L | 636 ₹6.2 L | 595 ₹5.8 L | 707.49 ₹6.9 L |
| 7.03 | Lintels, beams, plinth beams, girders, brassumers and cantilevers | 860.27 | SQM | 530.57 ₹4.6 L | 528 ₹4.5 L | 504 ₹4.3 L | 500 ₹4.3 L | 561.87 ₹4.8 L |
Tender Value
₹3.1 Cr
EMD Value
₹6.2 L
Closing Date
5 Mar 2026, 3:00 pmClosed
S.E, Irrigation Construction Circle, Basti
S.E, Irrigation Construction Circle, Basti
Construction of Residential building of Chief Engineer Level-1 (East) and Chief Engineer (Gandak) in Saryu Canal Colony Located In Distt- Gorakhpur.
2026_UPIDC_1119556_2
10/S.E/2025-26
Open Tender
Civil Works - Buildings
365 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,657
₹6.2 L
11 Mar 2026
23 Feb 2026
5 Mar 2026
23 Feb 2026
5 Mar 2026
24 Feb 2026
Excavaton work in excavation. Dry Earthwork in foundation building work including lead up to 30M and lift upto 1.5M and its disposal. As directed by Engineer-in charge. All kinds of soil
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 70.00 Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distance of 50m out side the periphery of area cleared. under floor Local Sand.
Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering. Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P. (b) mechanical mixing + Labour cost.(M15) (1:2:4)
Cement concrete with stone grit in RCC work excluding all cost of material but inclusive of labour and T&P and also excluding centering, shuttering and reinforcement. (b) mechanical mixing and Extra for mechanical vibration with 1% water charges. Total Concrete work for structure. (M25) (1:1:2)
Thermo-Mechanically Treated bars work such as in reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.
Backfilling the footings, Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty. Upto 10 km extra lead.
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, brassumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Edges of slabs and breaks in floors and walls (Under 20cm wide)
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 sand (zone- III) derieved from natural source : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Brick work in 1:4 cement mortar upto 3M lift and 60M lead of materials including scaffolding.
Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections. AT PORTICO ONLY
12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall.
15 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall.
Floor Finishing or Preparation at Ground Floor
Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty. Upto 15km extra lead. (soil filling from N.G.L to F.F.L).
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 70 Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distance of 50m out side the periphery of area cleared. under floor Local Sand.
Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering. Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P. (b) mechanical mixing + Labour cost
Providing and injecting chemical emulsion for preconstructional antitemite treatment and creating a chemical barrier under and around the column pits/wall trench/basement excavation top surface of plinth filling/junction of wall and floor along the external perimeter/building expansion joints, surrounding of pipes and conduits etc. complete/plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981) aldrine emulsifiable concrete or any other approved material such as hephachlor or chlordance will be used. The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonry & foundation 5 litres per sq.m. (2) back fill in immediate contact with foundation 7.5 litre per sq.m (3) treatment of top surface of plinth filling 5 liters per sq.m (4) treatment of soil along external parameter of building 7.50.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.(1 M WIDE)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
White washing with lime on undercoated wall surface two coats, to give an even shade including thoroughly brooming the surface, to remove all dirt, dust, mortar drops and other foreign matter.
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. (exterior+interior)
Doors & Windows Parts
Providing and fixing aluminium tower bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(200x10)
Providing and fixing aluminium tower bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(100x10)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(250x16)
Providing and fixing aluminium handles, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(100 mm)
Providing and fixing aluminium hanging floor door stopper, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(single)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid separately). (Sal Wood)
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing and fixing M.S. Grill of required pattern in frame of windows etc. with MS flats, square or round bars etc. including priming coat with approaved steel primer all complete. Fixed to openings/wooden frames with rawl plugs screws etc. Window grill complete.
Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire dia 0.5mm and average width of aperture 1.4mm in both directions for doors, windows and clerestory windows with necessary screws: 35mm thick shutters
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35mm thick door panel
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire dia of 0.63mm all complete. With second class teak wood beading 62x19 mm.
Providing and fixing panelled or panelled and glazed shutters for door, windows and clerestory window , fixing butt hinges of required size with necessary screw, excluding panelling which will be paid for separately, all complete as per direction of engineer-in-charge. 30mm thick window panel
Providing and fixing ISI marked alumunium butt hinges anodised (anodic coating not less than Grade AC 10 as per IS 1868) transparent or dyed to required colour or shade with necessary screw etc. complete.
100X63X3.2 (Doors)
75X45X3.2 (Windows)
Providing and fixing Chromium Plated brass casement window fastener with necessary screws etc. complete. 200mm wighting not less than 240 gms
(A) Applying ready mix primer including cost of material. b) Wood surface (Rates inclusive of repairing surface, preparing of surface by thoroughly cleaning oil, grease, dirt and other foreign material and scour with wire brush etc.
(A) Painting 1st coat over priming coat (but excluding cost of priming coat) on steel and other metal surface including cleaning the surface of all dirt, dust and other foreign matter, sand papering and stopping including cost of materials labour Tools and Plants etc. as required for proper completion of work. Paint shall be used as per standard I.S. specification. (B) Same as in Item No. 2 (A) above but on new wood surface.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).(Stair's Railings)
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Stone tile work for wall lining up to 10m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade. Granite stone of any colour and shade
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.(1.2mX2.1m)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover.(2*4*3=24)
Earthwork by power Transport for a lead of up to 1 Km. including excavation loading, unloading, stacking, manual compaction & dressing including all lift shall be applicable for lead up to 1 Km. Excluding Royalty. Upto 10 km extra lead.
P/F European type white glazed earthen wire W.C. pan (Indian make) of approved quality ISI marked Bakelite seat cover & lid with C.P. brass hinges and rubber buffers.
P/F 100mm size ‘P’ or ‘S’ trap for water closed squatting pan including jointing the trap with the pan and pipe in cement mortar 1:1 (1 Cement: 1 Fine sand)
P/F 10 lit. acrylic/PVC flushing cistern with C.I. or M.S. bracket complete with fitting such as Symphonic arrangement, 15mm normal size brass valve with polythene float, C.P. brass handle, unions & coupling for connections with inlet, outlet and overflow pipes, 40mm dia P.V.C. flush band, including cutting holes in wall and making good the same and connecting the flush band the same and connecting the flush band with cistern and closest.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap.
Providing and fixing Salem Skinless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board
510x1040 mm bowl depth 200 mm
P/F C.P. brass angle valve for cistern, wash basin Geyser etc. 15mm nominal hole size including cost of all materials, labour T&P etc.
P/F 15mm nominal hole size C.P. brass pillar cocks.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
P/F 600X400mm leveled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestors sheet ground fixed to wooden cleats with C.P. brass screws and washers.
P/F C.P. Brass toilet paper holders including cost of all materials, labours T&P etc.
P/F in position 100mm dia C.I. Nahani trap with hinged perforated cover complete with gasket and chaulked joints, including making necessary chases and hole in floor and walls and repairing the same to the original conditional completed.
Providing laying & fixing in position salt glazes S.W. full round pipe, I.S. 651 (Grade-A) with 1:2 cm with spun yarn or gasket laid underground over 15cm CC 1:4:8 and encased in proper gradient including excavation of trenches upto 2m depth.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 100 mm outlet
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Fixing 15mm PVC connection, heavy quality with brass Union including supply of all materials, labour T&P etc. required for proper completion of the work.
30 cm length
20 mm nominal bore
P/F copper alloy bib cock IS: 781-1977 complete with all materials
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15mm nominal bore
Making khurras 45×45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler
Shoe plain
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
P/F square mouthed S.W. gully trap I.S. 651 (Grade-A) complete with C.I. grating brick masonry chamber and water fight C.I. cover frame 30X30cm size (inside) the weight of cover to be not less than 4.53 kg. and frame be not less than 2.72 kg. as per standard design including excavation etc. complete.
P/F in position C.I. man hole cover and frames, IS:7267 embedded in R.C. cover and slab all exposed edges rounded and finished 1:3 cm etc. complete. (a) Fixing man hole cover light duty with frame 38kgs.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. Pipes, cables etc. not exceeding 80 mm dia (TENTATIVE)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end).
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Dry Earthwork in foundation building work including lead up to 30M and lift upto 1.5M and its disposal. As directed by Engineer-in charge. All kinds of soil.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and revelling the sub grade and disposal of surplus earth with lead upto 50 metres.
Plain cement concrete with stone ballast/brick ballast excluding cost of material but inclusive of labour and T&P etc excluding Shuttering. Plain cement concrete as per item-1 with 20% plum with stone ballast excluding cost of material but including of labour and T&P. (b) mechanical mixing + Labour cost.(M15) (1:2:4)
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & atten over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking payer blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of payer blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineering Charge. 80mm thick Cement concrete payer block of M-30 grade with approved colour; design & pattern.
Wiring point for light fan with 1.5sq. mm P.V.C. insulated and P.V.C. sheathed T.R.S. single core cable with 1.5sq. mm. P.V.C. Insulated T.R.S. Single core cable earth continuity on teak wood Batten and surface type switch etc, complete in all respect.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing call bell/buzzer suitable for single phase, 230V, complete as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep
Extra for fixing the louvers/shutters complete with frame for an exhaust fan of all sizes.
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. AC
Supplying and fixing PVC batten/angle holder including connections etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA, TP MCCB
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A MCB
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A RCCB
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
EARTHING
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Joining shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.
3-1/2 X 25 sq.mm
3-1/2 X 120 sq.mm
3-1/2 X 240 sq.mm
4 X 16 sq.mm (28mm)
Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR Civil 2023 Item no. 10.18.)
Supplying and laying of aluminum conductor PVC sheathed cable 1100 Volts grouting with MS clamps of suitable size as directed in all respect. All mounting shall be properly connected with earth conductor by clamps but excluding cost of cable tray. (MV CABLE).
120 sq mm 3-1/2 core
240 sq mm 3-1/2 core
25 sq mm 3-1/2 core
16 sq mm 4 core
100 Amp. MCCB - 2 Nos.(CATA+CATB)
63 Amp. MCCB - 3 Nos.(CATA+CATB)
100 Amp. MCCB - 3 Nos.(CATA+CATB)
Supplying and fixing factory wire H.P.F. box type florescent tube light fitting suitable for 1X40 watt florescent tube complete, including tube etc. on surface complete in all respect of Philips/Bajaj/ G.E.C./Crompton make.
Supplying and fixing of 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing of brass batten/angle holder including connection etc. as per required.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of granular sub-base by providing closed graded material confirming to specification, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all lads and lifts, spreading in a uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory powered roller to achieve the desired density, complete as per specifications and direction of engineer-in- charge. With material confirming to grade (size range 75 mm to 0.075 mm) having CBR value - 30.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). M-25 grade (1:1:2) concrete in C.C. pavement.(150 MM)
Providing and lying non pressure NP-4 class (heavy duty) RCC pipes including collers/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. 450 mm dia RCC pipes.
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supply & fixing of 7.0 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thick) having 3mm thickness with single arm bracket (1 Mr length) on RCC foundation including the cost of Each foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. @ 12M.
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Each and above Protection complete in all respect. CAT AAA
Supply and buying of 600mm x 600 mm x 6mm G.I. plate, vertically for earthing with its top at least 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8 to 108 WC G.I.wire in 15mm dia GI. pipe upto switch board (from apron to switch board the cost of G.I. pipe each and G.I. wire will be extra).30cm.square C.I. frame with hinged cover, masonary housing, alternate layers(of charcoal/coke and salt at least 150mm thick all-round etc. complete in all respects.
Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side.
supply and fixing of 40 amp TPN automatic street light cubicle control panel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs etc. complete in all respect. (cost included in street light near residential buildings).
Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top. On surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size
size 10 sq mm x 2 core
size 16 sq mm x 4 core
Supply and fixing of brass nickel plated compression gland for pvc insulated & armoured served sheaththed underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable.
size 10 sq mm x 2 core
size 16 sq mm x 4 core
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for PVC insulated & armoured cable insulating with tape and making connection. Complete in all respect as per direction of engineer –in-charge. for cable
size 10 sq mm
size 16 sq mm
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.49 MB
Lot_2.pdf
Tender Documents • 4.65 MB
BOQ_2081839.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid