Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹18.5 L+₹1.4 L (8.06%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Higher | |
| 3 | L3₹19.9 L+₹2.8 L (16.3%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance Higher | |
| 4 | L4₹21.8 L+₹4.6 L (27.0%)Rejected-Finance | L4 | Rejected-Finance Higher | |
| 5 | L5₹21.9 L+₹4.7 L (27.5%)Rejected-Finance | L5 | Rejected-Finance Higher |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Aug 2021, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
REPAIR / MAINT OF PUMP SET, MOTORS AND ALLIED WORK AT WATER SUPPLY PUMP HOUSE AT NAMS
2021_MES_460181_1
GE NAMS - 10 / 21 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAMS CANTT
Class D
Category a i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹70,000
Yes
18 Oct 2021
15 Jul 2021
16 Aug 2021
15 Jul 2021
14 Aug 2021
30 Jul 2021
Amount
M&L for taking out / lifting from bore well and shifting submersible pump/motor set to wksp for repairing including dismantling / opeing carefully all burnt winding wire by strip opening of 3 phase A.C submersible motor, any make of the following capacity as mentioned below and rewinding the motor with PVC insulated superior quality water proof submersible motor copper winding wire of suitable size including PVC shelves, Varnishing, backing etc and reassembling, testing and lowering the submersible pump set in borevwell complete all as specified and directed Note : (a ) The cost of copper winding wire of any size/gauge deemed to included in this job.(b) The Cost of transportation such as vehicle , T & P and man power deemd to include in this job.(c) Old Copper winding wire will be the property of Contractor.
40 HP to 45 HP
30 HP to 35 HP
20 HP to 25 HP
1 HP to 2 HP
S&F in replacement of thrust plate of the same make as of submersible motor of following capacity:-
S&F in replacement of rubber bush suitable for the following capacity submersible electric motor complete all as specified and directed.
40 HP to 45 HP
30 HP to 35 HP
20 HP to 25 HP
1 HP to 2 HP
S&F in replacement of stainless steel bush with key suitable for the following capacity submersible motor complete all as specified and directed.
40 HP to 45 HP
30 HP to 35 HP
20 HP to 25 HP
1 HP to 2 HP
S&F in replacement of mechanical oil seal suitable for the following capacity of submersible pump motor complete all as specified and directed :-
40 HP to 45 HP
30 HP to 35 HP
20 HP to 25 HP
1 HP to 2 HP
M&L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 60 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
Pump shaft of stainless steel of suitable size.
Impellor bronze/gun metal of suitable size.
CI neck ring.
Gun metal bush
Sand cup.
Shaft coupling of stainless steel.
M&L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 40 to 45 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
Pump shaft of stainless steel of suitable size.
Impellor bronze/gun metal of suitable size.
CI neck ring.
Gun metal bush
Sand cup.
Shaft coupling of stainless steel.
M&L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 30 to 35 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
Pump shaft of stainless steel of suitable size.
Impellor bronze/gun metal of suitable size.
CI neck ring.
Gun metal bush
Sand cup.
Shaft coupling of stainless steel.
M&L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 20 to 25 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
Pump shaft of stainless steel of suitable size.
Impellor bronze/gun metal of suitable size.
CI neck ring.
Gun metal bush
Sand cup.
Shaft coupling of stainless steel.
M&L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 10 HP to 15 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
Pump shaft of stainless steel of suitable size.
Impellor bronze/gun metal of suitable size.
CI neck ring.
Gun metal bush
M&L for re-metalling of gun metal/bronze/impeller, turning, facing of required size.10 to 25 HP
M&L for taking out / lifting from bore well dismentaling, opening of any type of submersible pump set 1 HP to 2 HP of any stage/size/make and re-assembling the pump after repair/replacement of the defective parts of pump testing and lowering the pump complete all as specified and directed. Note: The following defective parts replacement will be measured and paid separetly.
Material and labour in replacement the spares/componance of motor protection starter in panel complete all as specified and directed as follows :-
3 Pole power contactor type MNX 25
Supply and fixing in replacement 3 Pole power contactor type MNX 40
Supply and fixing in replacement 3 Pole power contactor type MNX 70
Supply and fixing in replacement 3 Pole power contactor type MNX 95
Single phase preventor SCP 4 type.
Relay range 36 Amp to 60 Amp MN-5. Make-L & T/Siemes/Ligrand/Havells
Timmer ET 100 to 30 sec 415 volt Make-L & T/Siemens/Legrand/Havells/GIC
Motor protection relay range 9-45 A
Add on auxiliary contact block type MNX 1NO + 1NC
Supply & fixing in Replacement including connecting, commissioning and testing of LT panel . Intdoor type panel ,weather proof , dust and vermin proof (IP 4X) suitable for 440 V grade 3 phase 50 HZ AC supply floor mounted with front door and Back opening having locking arrangement on both sides prewired with copper conductor PVC insulated flexible wire size not less than 1.5 sq mm / extension strips and connected with suitable size copper thimbles / lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:2:4 type B-1 [using 20 mm graded crushed stone aggregate] of suitable size including locking arrangement on both sides suitable for mounting , with required sheet metal enclosures, thimbles , based application complete all as specified and directed by Engr-in-Charge and comprising of the following accessories (a) Incommer MCCB 200 Amp , Four Pole, Thermal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 36KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication , Standard Extended Rotary Handle, Spreaders, Phase Barrier. (b) Metering Section- Digital Voltmeter showing 0-500V with duly prewired with copper cable of suitalbe size with 3x2A SP MCB, 3 x indicators RYB-01 No
(c) Metering Section- Digital Ammeter showing 0-500V with duly prewired with copper cable of suitalbe size with 3x2A SP MCB, 3 x indicators RYB-01 No (d) Insulated Busbar of Aluminium of 200A Capacity for 3 phase,, fixed on Insulators, Busbar shall be PVC Sleeved with red / Yellow/ Blue Colour, Busbar Support shall be of SMC/DMC - 1 set. (e) Outgoing MCCB 160 Amp , Four Pole, Thermal based release with adjustable O/L ,Adj S/C Setting Class II Front Face, 25KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication , Standard Extended Rotary Handle, Spreaders, Phase Barrier.
Outgoing MCB 32 Amp , Four Pole, 10kA breaking capacity with fault indication (a) MCCB auxilary contacts 1 No (b) Trip alarm Contact (c)Shunt trip 220VAC (d) Emergency stop push button stay put mashroom head with element (e) 06A SP 10KA MCB - For control "C" curve (f) softstarter Rating 37kW (g) main power contctor AC3 70A
Ventilating fans of required size to dissipate the heat with automatic switching on/off of fans depending upon the temperature of the panel, 230VAC 1500rpm, 160cum/h flying leads. Notes for LT Panels : 1. Make of Switchgear and Panel Board should be same .Make of Panel -Siemens , ABB or L&T-ISP 4. All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of 3.15 MM thick MS/CRCA sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. 5. Panel should confirms to IS/IEC-61439
Supply and fix in replacement of submercible flat 16 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
Supply and fix in replacement of submercible flat 10 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
Supply and fix in replacement of submercible flat 25 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
Supply in replacement of MS Nut bolts machine made with hexagonal or square head at one end screwed the other, each screws and to be fitted with washers and nut, exc 5 cm but not exc 10 cm long and dia of bolt 10cm complete all as specified and directed.
Material and labour for Repair to pump house bore well cap cover made out from mild steel sheet 3 mm thick and angle iron frame in any shape and size complete with making holes , nut bolts welding etc as reqd at site including painting of two coat of shynthectic enamel paint over a coat of red oxide complete all as specified and directed.
Supply and fix in replacement of MCCB 100 Amp , 3 pole, 415 volt, 16KA
Supply and fix in replacement of MCCB 200 Amp, 4 pole , 415 Volt, 36 KA
Supply and fix in replacement of MCCB 250 Amp, 4 pole , 415 Volt, 36 KA
To attend elect complaint of water supply installations replacing burnt lugs of cable, to check auto star delta starter, voltmeter, ampere meter or any other items in pump panel changeover switch and make functional if minor repair involves to above equipments complete all as specified and directed.
Supply only Calcium based granual dis infectant for water treatement more stable than chlorine gas and stronger than bleaching powder and Calcium Hypo chlorite 65% to 70% Chlorine content in granular. (Packing in Plastic drum) as appoved by E-In-C's all as specified and directed.
Supply and fixing in replacement Digital Ampere meter.
Supply and fixing in replacement Digital Voltmeter.
Supply and fix in replacement Push Button Red & Green for On and Off.
Supply and fix in replacement 3 Phase indicater R,Y, B - 01 set of three
All as per item 22 here in before but Cat Part No CSXI-030-41 complete.
M/s Vijay Construction Co.
HARPAL ENGINEERS AND BUILDERS
diamond electrical
M/S RASHPAL CONSTRUCTION CO
M/s AKG Engineers & Contractors
Mahajan Builder
M/s Shiv Electrical & Mechanical Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .