| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAdmitted-Finance 251 TATA KANDRA MAIN ROAD ADITYAPUR SERAIKELLA KHARSAWAN JHARKHAND PIN 831013 | SARAIKELA KHARSAWAN | JHARKHAND | 831013 | ₹4.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.8 CrAdmitted-Finance ADD DHATKIDIH MARKET P O P S BISTUPUR DIST EAST SINGHBHUM JHARKHAND | ₹4.8 Cr | L2 | Admitted-Finance |
| 3 | L3₹4.8 CrAdmitted-Finance FLAT NO 2B SWARANA PALACE GAMHARIYA SERAIKELA KHARSAWAN 832108 JHARKHAND | GAMHARIYA | SERAIKELA KHARSAWAN | JHARKHAND | 832108 | ₹4.8 Cr | L3 | Admitted-Finance |
| 4 | L4₹4.9 CrAdmitted-Finance 47 ABC TARUN NAGAR BY LANE 6 BY LANE 6 GUAWHATI KAMRUP ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | ₹4.9 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GAYATRI ENGINEERING WORKS L1 | M/S BHARAT ENGINEERING L2 | SHIVAM AND COMPANY L4 | GEETRAJ ENGINEERING PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in 91 DELHI SCHEDULE OF RATES (E&M)-2025 meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232. c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided. d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices. e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other 92 DELHI SCHEDULE OF RATES (E&M)-2025 accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc. f) Lightning, surge voltage protection, earthing protection and grid islanding. g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required. h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. | 750 | Per KWP | 40,000 ₹3,00,00,000 Lowest | 45,265 ₹3,39,48,750 | 44,509.6 ₹3,33,82,200 | 43,619.36 ₹3,27,14,520 |
| 2.00 | Dismentling of exhisting structures like culverts, bridges, retaining walls and other structure comprising of masonary , cement concrete ,wood work, steel work, includingT&P and scaffolding wherever necessary, sorting the dismentied material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 meters | 148.19 | m3 | 350 ₹51,866.5 Lowest | 373.3 ₹55,319.33 | 373.3 ₹55,319.33 | 365.54 ₹54,169.37 |
| 3.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 63.93 | m3 | 100 ₹6,392.6 Lowest | 151.89 ₹9,709.72 | 151.89 ₹9,709.72 | 148.85 ₹9,515.39 |
| 4.00 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) | 63.93 | m3 | 10 ₹639.26 Lowest | 15.51 ₹991.49 | 15.51 ₹991.49 | 15.2 ₹971.68 |
| 5.00 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) | 413.18 | m3 | 500 ₹2,06,590 Lowest | 589.51 ₹2,43,573.74 | 589.51 ₹2,43,573.74 | 577.72 ₹2,38,702.35 |
| 6.00 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 43.13 | m3 | 50 ₹2,156.5 Lowest | 55.28 ₹2,384.23 | 55.28 ₹2,384.23 | 54.17 ₹2,336.35 |
| 7.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 405.3 | m3 | 4,200 ₹17,02,260 Lowest | 5,900 ₹23,91,270 | 4,598.23 ₹18,63,662.62 | 4,506.26 ₹18,26,387.18 |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size | 17.58 | m3 | 5,000 ₹87,900 Lowest | 5,400 ₹94,932 | 5,218 ₹91,732.44 | 5,113.63 ₹89,897.62 |
| 9.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) | 20.59 | m3 | 5,600 ₹1,15,281.6 Lowest | 8,000 ₹1,64,688 | 6,082.45 ₹1,25,213.32 | 5,960.79 ₹1,22,708.82 |
| 10.00 | Providing 75A brick work in C.M. (1:4) in Superstructure -do- -do- all complete job as per specification and direction of E/I. | 74.79 | m3 | 5,500 ₹4,11,339.5 Lowest | 5,752.05 ₹4,30,190.07 | 5,752.05 ₹4,30,190.07 | 5,637 ₹4,21,585.59 |
Tender Value
₹4.9 Cr
EMD Value
₹4.9 L
Closing Date
3 Jun 2026, 5:00 pmClosed
Executive Engineer, Mechanical Division, Chandil
Executive Engineer, Mechanical Division, Chandil
Fabrication and erection of solar plant for supply of electricity in Chandil Dam, Colony and office building in Mechanical Workshop area after auction of condemned heavy earth mover machine with five years maintenance
2026_WRD_113974_1
WRD/MD/CHANDIL/SBD-01/2026-27
Open Tender
Electrical Works
Item Rate
180 days
Chandil
Please refer Tender documents.
9 documents required · 9 mandatory
₹10,000
₹4.9 L
Yes
14 Aug 2026
14 May 2026
4 Jun 2026
14 May 2026
3 Jun 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in 91 DELHI SCHEDULE OF RATES (E&M)-2025 meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232. c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided. d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices. e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other 92 DELHI SCHEDULE OF RATES (E&M)-2025 accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc. f) Lightning, surge voltage protection, earthing protection and grid islanding. g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required. h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. | 750 | Per KWP | 44,509.6 | ₹3,33,82,200 |
| 2 | Dismentling of exhisting structures like culverts, bridges, retaining walls and other structure comprising of masonary , cement concrete ,wood work, steel work, includingT&P and scaffolding wherever necessary, sorting the dismentied material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 meters | 148.19 | m3 | 373.3 | ₹55,319.33 |
| 3 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 63.93 | m3 | 151.89 | ₹9,709.72 |
| 4 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) | 63.93 | m3 | 15.51 | ₹991.49 |
| 5 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) | 413.18 | m3 | 589.51 | ₹2,43,573.74 |
| 6 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 43.13 | m3 | 55.28 | ₹2,384.23 |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 405.3 | m3 | 4,598.23 | ₹18,63,662.62 |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size | 17.58 | m3 | 5,218 | ₹91,732.44 |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) | 1 | m3 | 6,082.45 | ₹6,076.37 |
| 10 | Providing 75A brick work in C.M. (1:4) in Superstructure -do- -do- all complete job as per specification and direction of E/I. | 74.79 | m3 | 5,752.05 | ₹4,30,190.07 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.77 MB
design.pdf
Additional Documents • 1.22 MB
document.pdf
Tender Documents • 1.47 MB
Tech_Specification.pdf
Additional Documents • 0.34 MB
BOQ_153972.xls
BOQ • 0.27 MB
tech.pdf
Additional Documents • 2.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].