Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 106 DR LALIT BANERJEE SARANI GROUND FLOOR KOLKATA 700073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹6.5 L+₹89,136 (15.8%)Rejected-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L2 | Rejected-AOC 2nd Lowest Bidder | |
| 3 | L3₹6.7 L+₹1.1 L (18.9%)Rejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700 029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | L4₹7.1 L+₹1.4 L (25.5%)Rejected-Finance 3 N K CHATTERJEE STREET KOLKATA 700 056 | KOLKATA | KOLKATA | WEST BENGAL | 700056 | L4 | Rejected-Finance 4th Lowest Bidder | |
| 5 | L5₹7.2 L+₹1.6 L (27.7%)Rejected-Finance 64 SARAT BOSE ROAD BHOWNIPUR 700 025 | BHOWNIPUR | KOLKATA | WEST BENGAL | 700025 | L5 | Rejected-Finance 5th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹16,500
Closing Date
14 Jul 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-I, WKED, PWD
New Sectt. Building, 1, K.S. Roy Road, C-Block, 4th floor, Kolkata-700 001
Annual Comprehensive Maintenance of 340 TR Central A.C. Plant installed at Main Building, High Court, Calcutta.
2020_WBPWD_287550_1
WBPWD/EE-WKED/NIQ-02/2020-21
Open Tender
ELECTRICAL WORKS M/R
Item Rate
365 days
High Court
Please refer Tender documents.
3 documents required · 3 mandatory
₹16,500
Yes
4 Nov 2020
29 Jun 2020
16 Jul 2020
29 Jun 2020
14 Jul 2020
30 Jun 2020
90 days
Amount
Annual Comprehensive Maintenance of 340 Tr. (2x80 Tr. + 3x40Tr. + 2x30Tr.) Chilled water Central AC plant installed at Main Building, High Court Calcutta as per terms and conditions.
Scope of Work & Terms and Conditions:
The Central A.C. plant consists of the following items: A) Compressor along with respective motor, condenser, chilled and accessories. i) 30TR - 2 (Two) nos. ii) 40 TR- 3 (three) nos. iii) 80TR - 2 (two) nos. B) Air Handling Units: 9 (nine) nos. i) Court Rooms no. 2 to 4 ii) Court Rooms: 5 to 7. iii) Court Room no. : 8, iv) Court Rooms no. : 9 to 10. v) Court Room no. : 11, vi) Court Room no. :12, vii) Court Rooms no. : 13 to 18, viii) Court Rooms no. : 19, ix) Court Rooms no. 20 to 23, C) Cooling Tower (each 225 TR. FRP, Make: Paharpur): 2 (two) nos. D) Pump - Motor Sets: i) Condenser Pump-Motor Set : 8 (eight) sets. ii) Primary Chilled water Pump-Motor: 12 (twelve) sets. E) U.G. chilled water tank (inside insulated) : 2 (two) nos. i) Primary chilled water tank, ii) Secondary chilled water tank. F) Allied pipe lines including insulations: As laying. G) Control Panel including main switches, starters etc: 1 (One) unit.
SCOPE OF WORKS ARE AS FOLLOWS: 1. AMC inclusive of replacement of defective spare, attend all break down calls and rectify the same within 24 hrs., overhauling entire machine (once in a year) preventive maintenance (Quarterly), dicaling of condenser (Once/twice in a year / when it requires) with all reairing work like compressor, condenser, chiller, condenser pump, chiller pump, AHU, Blower Motor, Cooling Tower, Ducting (Air-Distributing System) including Electrical Panel Board etc. as and when required and as per direction of Engg-in-Charge. 2. Scope of work shall include all risk protection, Annual comprehensive Maintenance contract for the air condition system, including repair, servicing, replacement of spares, except those mentioned exclusio. 3.However total air-conditioning system will be checked for its proper functioning periodically through preventive maintenance.
A. CHILLER PACKAGE: 1. Checking and rectification, if required for abnormal noise, vibration normal wear & tear for continuous operation. 2. Checking for leakage of oil, refrigerant etc. & replacement if required. 3. Checking operation of crankcase heater, water flow switch, loading/unloading, Overloading etc. & to do all sorts of rectification to run the plant smoothly. 4. Checking and rectification of electromechanical starter panel. 5. Develop action plan for rectifying abnormalities if any observed in performance of the system & to carry out the work under instruction of EIC. 6. To attended breakdonw calls as and when required, investigation / locate defects, replace of defective part and re-commissioning the system within reasonsable time & in no way the service to Hon'ble High Court can be hampered. 7. Through checking of all instruments like solenoid valves, refrigerant pressure gauges, safety switches, drieret for its proper operation mode. 8. Checking & rectification of all electrical termination including control connection inside the Electro-Mechanical starter panel & replacement of all wornout HRC fuses MCC panle.
B. AIR-HANDLING UNIT: 1. Inspection and cleaning of all filters bi-weekly. 2. Clealing of all cooling coils bi-weekly. 3. Checking of operation of fan, impeller, drive pully, belt, tension, beaking noise, abnormal sound, motor vibration and necessary rectification as and when required. 4. Cleaning of drain trays and drain pipes. 5. Checking and rectification of AHU starter, fuses and all electrical connection as and when required. 6. Checking of MCC feeders etc.
C. COOLING TOWER: 1. Topping up lubricating oil for cooling tower gear drive as and when required. 2. Cleaning of distribution trays, nozzles, strainers, sump etc. 3. Checking and tightening of all electrical terminals. 4. Checking of vibration and any abnormal operation of fans. (Primary & Secondary water pump).
D. PUMPS: 1. Checking and rectification / replacement of all bearing if required. 2. Checking and alignment of pump. 3. Checking of gland packing / replacement if required. 4. Checking of bearking and setright the pump set.
E. MCC CUM CONTROL PANEL AND LOCAL STARTER: 1. Checking of tighteness of all termination. 2. Checking of all switch grars forts proper operation. 3. Checking of panel for abnormal heating. 4. Inspection of individual cabinet for its proper operation. 5. Checking of entire circuit periodically.
F. VALVES AND STRAINERS: 1. Checking of valves for its proper operation and free movement of lever. 2. Perodical cleaning of all strainers for the entire chilled water and condenser water ciruciit.
ANNUAL MAINTENANCE: The total plant will be overhaulted once in a year preferably during winter moths, prior permission will have to be taken to carry out the job.
GENERAL MAINTENANCE: All breakdown calls will be attended promptly.
EXCLUSION: 1. Any replacement required because of theft or fire. 2. Any modification, shifting, alternation of suit future requirement. 3. Any minor replacement of air distribution system namely ducting & insulation. 4. Replacement of cables. 5. Any minor/replacement of water distribution system namely piping and valves. 6 Replacement of any equipment as a whole e.g. compressor, condessor, chiller, pumps, motors, AHU, FCU, Valves, Fans etc.
TERMS AND CONDITIONS: 1. Supervision will continue or regular basis by qualified engineer. 2. Plant will run uninterrupted during court hours. 3. Temperature inside Court rooms should be satisfactory. 4. Regular maintenance work should be as per scope of work. 5. Terms of payment as per PWD norms.
BLUE STAR LIMITED
Shinryo Suvidha Engineers India Pvt Ltd
P. M. COOLING AND ENGINEERING CO
REFRIGERATION AND AIRCONDITIONING CORPORATION
WEATHER CONTROLS
stage.html
html • 0.06 MB
technical_534353.pdf
PDF • 0.03 MB
techsummary_534353.pdf
PDF • 0.04 MB
finance_534353.pdf
PDF • 0.04 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_534353.pdf
PDF • 0.07 MB
FinalAcc-niq-02-2020-21.pdf
PDF • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .