Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹19.2 L+₹1.8 L (10.6%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹19.9 L+₹2.5 L (14.6%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹22.0 L+₹4.6 L (26.8%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹24.8 L+₹7.4 L (42.9%)Rejected-AOC SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
26 May 2021, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon NEAR ATUL KATARIA CHOWK GURGAON 122005
GE (P) AF/GUR-16/2021-22 REPAIR, MAINT AND SERVICING OF CEILING FAN, EXHAUST FAN, AIR CIRCULATOR, ELECTRIC METER INCLUDING REPLACEMENT OF OLD U/S POINT WIRING AND SUB MAIN WIRING AND CONNECTED WORK AT AF STN GURGAON UNDER GE (P) AF GURGAON
2021_MES_439009_1
GE (P) AF/GUR-16/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (P) AF Gurgaon
AS SPECIFIED IN NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹94,000
Yes
2 Jun 2021
28 Apr 2021
28 May 2021
28 Apr 2021
26 May 2021
12 May 2021
Amount
Taking down and serviceing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush gun metal ball bearing capacitor split and reassembling the fan complete including testing after assembling and connecting to electric system complete all as specified and as directed by Engr-in-Charge. NOTE:- Rates of bearing, capacitor, blades & painting will be paid seperately in the concered item of schedule.
All as per srl item No 1 above but for wall mounting fan plastic type of size 400/450mm sweep complete.
All as per srl item No 1 above but for exhaust fan of any size complete.
Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase complete at site for rewinding and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps including servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etc including testing after assembling and connecting to electric system complete all as specified and as directed by Engr-in-Charge. Note : 1. Rates of winding and replacement of any unserviceable parts mentioned above required to make the fan in serviceable condition are include in the quoted rate. 2. Old winding of the fans will be destroyed/damaged by the department before handing over the fan to contractor for repair. 3. After repair contractor will be fully responsible for checking of copper winding and thereafter the same will be assembed, re-hanging and electric connection complete. 4. Rates of bearing, bush, capacitor, blades & painting will be paid seperately in the concered item of schedule.
All as per srl item No 4 above but for wall mounting fan plastic type of size 400mm sweep complete.
All as per srl item No 4 above but for wall mounting fan plastic type of size 450mm sweep complete.
All as per srl item No 4 above but for exhaust fan of size 250mm sweep plastic type square/round shape complete .
All as per srl item No 4 above but for exhaust fan300mm sweep complete.
All as per srl item No 4 above but for exhaust fan 450mm sweep complete.
All as per srl item No 4 above but for exhaust fan 600mm sweep complete.
All as per srl item No 4 above but for air circulator wall mounting fan metallic type 450mm sweep complete.
All as per srl item No 4 above but for air circulator wall mounting fan metallic type 600mm sweep complete.
S&F in replacement capacitor 2.5 mfd + 5%, 220/230 volts AC, 50 c/s complete all as specified and as directed by Engr-in-Charge. Make: Usha/Epcos/Tibcon.
S&F in replacement capacitor 3.15 mfd + 5%, 220/230 volts AC, 50 c/s complete all as specified and as directed by Engr-in-Charge. Make: Usha/Epcos/Tibcon.
S&F in replacement capacitor 4 mfd + 5%, 400/440 volts AC, 50 c/s complete all as specified and as directed by Engr-in-Charge. Make: Usha/Epcos/Tibcon.
S&F in replacement Electric cable PVC insulated with copper conductor (flexible cable) size 23/0.0076 twin core for connecting fan to electric system, complete all as specified and as directed by Engr-in-Charge.
M & L in replacement for Remetaling to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of 1200/1400mm sweep of any make complete all as specified and as directed by Engr-in-Charge.
Taking down and Spray painting to AC ceiling fan 1200/1400mm sweep any make complete to motor assy, down rods, blades with ISI marked white/brown synthetic enamel paint as approved by Engr-in-Charge after preparation of surface including filling cavities with filler, writing of MES No complete and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
Taking down metallic type wall mounting fan of size 400/450mm sweep in situ for spray painting with ISI marked OG/brown/black synthetic enamel paint as directed by Engr-in-charge after preparation of surface and refixing the same in existing location after painting complete all as specified and as directed by Engr-in-charge.
All as per item No 19 hereinbefore but for exhaust fan 300mm.
All as per item No 19 hereinbefore but for exhaust fan exceeding 300mm and upto 450mm.
All as per item No 19 hereinbefore but for exhaust fan exceeding 450mm and upto 600mm.
All as per item No 19 hereinbefore but for air circulator wall mounting fan of size 450 to 600mm .
S&F in replacement Canopies for AC ceiling fan of size 1200/1400mm sweep for any make of fan complete all as specified and as directed by Engr-in-charge.
S&F in replacement down rods for ceiling fan 1200/1400mm sweep of size 2.5' long duly painted with white synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.
S & F in replacement Hanging clamp suitable for ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as directed by Engr-in-Charge.
S&F in replacement step type elctronic fan regulator in replacement Modular type 2 Module, single phase 220 V, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement step type elctronic fan regulator in replacement Flush type, single phase 220 V, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement louvers only for exhaust fan of size 300mm sweep made out of MS sheet 22 gauge complete all as specified and as directed by Engr-in-Charge.
S&F in replacement louvers only for exhaust fan of size 450mm sweep made out of MS sheet 22 gauge complete all as specified and as directed by Engr-in-Charge.
M&L in replacement fan blade (set of 03) suitable for 1200 mm sweep complete all as specified and as directed by Engr-in-Charge.
M&L in replacement fan blade (set of 03) suitable for 1400 mm sweep complete all as specified and as directed by Engr-in-Charge.
S&F in replacement wall mounted fans blades (set of 03) suitable for 400/450 mm sweep any make and suitable colour including taking down complete all as specified and as directed by Engr-in-Charge.
S&F in replacement exhaust fans blades suitable for 300/450 mm sweep any make and suitable colour including taking down complete all as specified and as directed by Engr-in-Charge.
S&F in replacement exhaust fans blades suitable for 600 mm sweep any make and suitable colour including taking down complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement Ball bearing suitable size of ceiling fan any type and size complete all as specified and as directed by Engr-in-Charge. Make : SKF/PNB/TATA
Supply and fix in replacement Ball bearing suitable size of Exhaust fan any type and size complete all as specified and as directed by Engr-in-Charge. Make : SKF/PNB/TATA
Supply and fix in replacement Ball bearing suitable size of wall maunted fan any type and size complete all as specified and as directed by Engr-in-Charge. Make : SKF/PNB/TATA
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, HRFR copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated HRFR copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
One light point controlled by one way one switch SP 5 Amps , 240 V.
One ceiling fan / Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
One light point controlled by two 2 way switch SP 5 Amps ,240 V.
One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
One switch socket outlet 3 Pin, 5 Amps, SP on same board.
One bell point controlled by one way one switch SP 5 Amps , 240 V.
All as per the item No 40 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular socket outlet 6A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular socket outlet 6A/16A, 2/3 pin combined 2 module, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular switch 2 way 6 Amps 1 module complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular switch 1 way 16 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement ceiling rose 3 phase/PVC/ polycarbonate isolated body, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement step type elctronic fan regulator Modular type, single phase 220 V , one module type, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement modular bell push switch 1 way 6 Amps 1 module, complete all as specified and as directed by Engineer-in-Charge.
M&L for Point wiring complete with HRFR PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded , copper conductor cable drawn through in non metallic rigid PVC conduit medium grade , minimum 20 mm dia conceled in wall , ISI Marked, and connect accessories, mounting on suface of walls / ceilings /roofs etc with shunken box anodised concealed in suface of wall , 3 mm thick laminated plastic sheet cover for mounting of switches, sockets outlets, regulators etc, fixed by suitable size of 04 Nos cadmium screwes including provision of HRFR PVC insulated unsheathed 1.5 Sqmm muiltistranded green colour copper conductor cable as earth connectivity and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-
One light point controlled by one way one switch SP 5 Amps , 240 V.
One ceiling fan/Exhaust point controlled by one way one switch SP 5 Amps, 240 V.
One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
One switch socket outlet 3 Pin, 5 Amps, SP on same board.
One bell point controlled by one way one switch SP 5 Amps , 240 V.
One light point controlled by two 2 way switch SP 5 Amps , 240 V.
All as per the item No 50 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch piano flush type single pole one way , 15 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 2 in 1 ,3 pin 5 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement socket outlet 2 in 1 ,3 pin 5 and15 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch bell push piano flush type single pole one way , 5 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement switch piano flush type single pole two way , 5 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement step type elctronic fan regulator flush type, single phase 220 V , one module type, complete all as specified and as directed by Engineer-in-Charge.
Taking out old U/S submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed.
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 6 Sqmm and one run of 6 Sqmm FR copper conductor as earth wire and connected to earth dolly all as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
M&L in replacement of sub main wiring with multistranded FR copper conductor cable PVC sheathed in and including concealed suitable size PVC conduit medium grade with fittings and two runs of 10 Sqmm and one run of 10 Sqmm FR copper conductor as earth wire and connected to earth dolly all as specified and as directed by Engr-in-Charge. ( The item includes cutting Chasis and making good the disturbed surfaces).
S&F in replacement of Ding Dong Bell, single phase, 230 volt AC, 50 HZ, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement , Batten holder bakelite AC, 220 V, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of sheet metal enclosure single pole and neutral 4 way Double door with two pin and earth plug & socket complete with one single pole MCB 240 Volts 20 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of sheet metal enclosure single pole and neutral 8 way Single door with two pin and earth plug & socket complete with one single pole MCB 240 Volts 20 Amps, complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of metal enclosure for MCB's (D.B) 12 way (SPN) 200 Amps rated bus bar complete all as specified and as directed. Cat No- DHDPSHODRW08 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement of sheet metal enclosure triple pole and neutral 415 Volts 6 way 200 amp rated Double door, complete all as specified and as directed by Engineer-in-Charge. Cat N0- DHDLVDRWG OFO04 Make Havells or equivalent out of makes specified in list of makes.
S&F in repairs sheet metal enclosure triple pole and neutral vertical Loadline 415 Volts 8 way (TPN) Double door Cat N0- DHDLVDRWGOFO08 Make Havells or equivalent out of makes specified in list of makes.
S&F in replacement MCB 240 volts SPN 06- 32 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F in replacement MCB 240 volts 2 pole (DP) - 40 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSNF006-032 Make Havells or equivalent out of makes specified in list of make.
S&F in replacement MCB 240 volts SP 6- 32 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed. Cat No- DHMCCSPF006-032 Make Havells or equivalent
S&F in replacement MCB 415volts TPN 63 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed, Cat No- DHMCCTNF063 of Make Havells or equivalent out of makes specified in list of make.
Supply & Fix in replacement of MCCB 4 pole 415 V fixed type 63 Amps with breaking capacity 10 KA complete all as specified and directed
S&F in replacement MCCB 100 Amps 4 pole 415 Volts 10 KA breaking capacity complete all as specified and directed, Cat No- 0270 39 of Make Legrand or equivalent out of makes specified in list of make.
S&F in replacement Blanking plates suitable for MCB DB's of Make Havells or equivalent out of makes specified in list of make.
Supply and fixing in replacement industrial panel mounting Socket Splash proof 16 amp protection degree 44 , code DHQCA65016 of Havells PIN 3P+N+E or equivalent out of makes specified in list of make
Supply and fixing in replacement industrial panel mounting Plug Splash proof 16 amp protection degree 44 , code DHQBA65016 of Havells PIN 3P+N+E or equivalent out of makes specified in list of make
S&F in replacement in replacement false ceiling light fittings with new energy saving LED ceiling light fitting of capacity 34 Watt including 3 core PVC insulated copper conductor upto ceiling rose and testing complete all as directed by Engr-in-charge. Make : Havells cat part No :- DROPDOWNFLAT2X2PLR34WLED840S or equivalent out of makes specified in list of makes.
Supply and Fix in replacement LED tube Rod T5 (icluding driver) 4 feet , complete all as directed by Engr-in-charge. PHOTONULTRAE2.01213T8SSTL18WLED865 SPC18/20 watt or equivalent out of makes specified in list of makes.
S & F in replacement of surface light to LED surfase light square 12 watt size 160 X160mm X 16(H)/ complete all as directed by Engr-in-charge. Cat No -EDGEPROSQD LR12WLED857S of Havells or equivalent out of makes specified in list of makes.
S & F in replacement of surface light to LED surfase light round 15 watt size : Ø 180 mm, height 16 mm complete all as directed by Engr-in-charge. Cat No-EDGEPRORDDLR15WLED857S of Havells or equivalent out of makes specified in list of makes.
S&F in replaceemnt of fluorescent tube light fittings with new energy saving LED T 8 Tube light Fitting 4 feet clear cool white 20 Watt with inbuilt LED Driver, complete all as directed by Engr-in-charge. Make : Havells Cat Part ENDURALINEARNEOBS20WLED865SPCWH or equivalent out of makes specified in list of makes.
Supply only in replacement of indoor decorative LED batten light fitting 1x9/10W tube light fitting with 2 feet long LED Tube of 9/10W complete with all accessories internally prewired complete all as specified and directed by Engineer-in-Charge. Make:- Surya/ SYSKA/ PHILIPS/ HAVELLS cat No ENDURALINEARNEOBS10WLED865SPCWH or equivalent out of makes specified in list of makes.
S&F in replacement of Gang box for 15 Amps socket complete including 15 Amps switch socket combination complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Gang box for 5 Amps socket complete including 5 Amps switch socket combination complete all as specified and directed by Engineer-in-Charge.
M&L for checking of Energy Meters single/three phase 2/4 wire of any Make /type including testing , checking and reporting any tempering and intimate meter reading at time of electric meter testing & re-sealing all as specified and directed. (NOTE: Necessary transportation upto building testing and checking arrangements with equipment and metre calibration certificate will be provided by contactor)
M&L for taking down unserviceable energy meter 1 phase from meter box after disconnecting all incoming and outgoing connection complete all as specified and as directed by Engr-in-charge .
M&L for taking down unserviceable energy meter 3 phase from meter box after disconnecting all incoming and outgoing connection complete all as specified and as directed by Engr-in-charge .
S&F in replacement single phase electronic energy meter 10-40A in poly carbonate body with LCD display in class 1.0 only kwh in meter box including making necessary electrical (incoming and outgoing) connection complete all as specified and as directed by Engr-in-charge. Make HPL/ L&T/Secure.
S&F in replacement three phase electronic energy meter 10-60A in poly carbonate body with LCD display in class 1.0 only kwh in meter box including making necessary electrical (incoming and outgoing) connection complete all as specified and as directed by Engr-in-charge. Make HPL/ L&T/Bentex.
S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 6 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement meter box made out of sheet metal enclosure suitable for electronic energy meter Single/three phase complete grouted in wall and making incoming and outgoing connection complete including making good disturbed suface as per existing complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of old wall bracket light to LED wall bracket light complete all as specified and directed by Engineer-in-Charge. Cat No- Halonix make HLWB-01-B22 or equivalent in Havells/Surya/Syska.
Note:- The amount of Rs 94,020/- against Schedule of Credit on Page No 117 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
Phogat Builders
M/S Anand Enterprises
PARKASH ENTERPRISES
Haryana EngineerService
SHAMMI ENTERPRISES
M/s NEERAJ KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .