Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.0 L+₹38,154.78 (4.44%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹10.0 L+₹1.4 L (16.5%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹11.7 L+₹3.2 L (36.7%)Rejected-Finance 149 BINDA PUR D K MOHAN GARDEN UTTAM NAGAR JANAK PURI C 1 WEST DELHI DELHI 110059 UDYAM DL 10 0026593 | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹11.8 L+₹3.2 L (37.2%)Rejected-Finance | L5 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
27 Feb 2024, 3:30 pmClosed
Principal
Rajdhani College, Raja Garden,New Delhi-110015
Waterproofing and Ceiling repair works of library roof
2024_DU_793839_1
RC/RG/LIBRAYWATERPROOF/2024/01
Open Tender
Civil Works
Works
45 days
Rajdhani College, Raja Garden, New Delhi-110015
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Principal,Rajdhani College
₹70,000
Yes
15 May 2024
6 Feb 2024
28 Feb 2024
6 Feb 2024
27 Feb 2024
6 Feb 2024
Civil work
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate 10 mm nominal size) with glass fibers and Dr. fixit LW+ waterproofing compound and application of cement slurry with waterproofing compount Dr. fixit URP on terrace before laying concrete.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Removal of existing waterpipe lines, refixing of same with mateiral required as per site
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after.
Chipping of unsound/weak concrete material from slabs, beams, columnsetc. with manual Chisel and/ or by standard power driven percussiontype or of approved make including tapering of all edges, making squareshoulders of cavities including cleaning the exposed concrete surface andreinforcement with wire brushes etc. and disposal of debris for all leadand lifts all complete as per direction of Engineer-In-Charge (including cleaning reinforcement )
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Baljeet Builders and Interior Decorators
ANIL KUMAR JAIN
M/S KUBER BUILD TECH
PLUS INCORPORATION
ACE CONSTRUCTION & WATERPROOFING CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .