| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC reasonable bid |
| 2 | L2₹1.9 Cr+₹4.4 L (2.39%)Rejected-Finance | ₹1.9 Cr+₹4.4 L (2.39%) | L2 | Rejected-Finance not lowest |
| 3 | L3₹1.9 Cr+₹5.4 L (2.90%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹1.9 Cr+₹5.4 L (2.90%) | L3 | Rejected-Finance not lowest |
| 4 | L4₹1.9 Cr+₹7.2 L (3.88%)Rejected-Finance | ₹1.9 Cr+₹7.2 L (3.88%) | L4 | Rejected-Finance not lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
13 Oct 2021, 6:00 pmClosed
CHIEF ENGINEER R N D SECUNDERABAD
CHIEF ENGINEER R N D SECUNDERABAD OPP JUBILEE BUS STAND PICKET SECUNDERABAD 500003
PROVN OF MD ACCN FOR DSC PERSONAL FOR DSC PLATOON FOR NEW RCI SITE AT DUNDIGAL HYD
2021_MES_470899_1
CERD/SEC/TOKEN/65 OF 2019 - 2020
Open Tender
Civil Works
Lump-sum
365 days
RCI HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE I R N D RCI Hyderabad
₹2.5 L
Yes
8 Dec 2021
26 Aug 2021
20 Oct 2021
26 Aug 2021
13 Oct 2021
30 Sept 2021
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.05) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Block of Married accomodation for 02 JCO's single storey with RCC framed structure with permanent specification including all fittings and fixtures complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Block of Married accommodation for 08 ORs in double storey with RCC framed structure with permanent specification including all fittings and fixtures complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Scooter Shed complete all as shown on drawings and as specified.
Construction of conventional RCC Septic tank 50 users with effective depth of 1.5 meter and overall depth of 3 meter complete all as shown on drawings and as specified.
Construction of Soak well of size 1.80m dia and 3.00 M effecive depth complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for “ ROAD AND CULVERT ” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `5,68,112.60 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `2,46,391.72 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `2,06,460.60 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “ INTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VI representing _______ % _________________ percent Above / Below the lump sum price of `63,922.90 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `1,48,494.20 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VIII representing ______ % _________________ percent Above / Below the lump sum price of `95,389.17 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of `3,90,871.07 inserted by the MES in Schedule ‘A’ Part - IX
Schedule 'A' Part - X This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 10.00 to 56.00
Point wiring complete with FRLS stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed cable up to 1100 V grade conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories concealed in walls etc., with sunk / surface type pressed steel terminal boxes made out of 1.6 mm MS sheet duly painted with two coats of red oxide zinc chrome primer with 2.8 mm thick laminated hylam sheet covers for mounting of switches, regulators and also including one run of 1.5 Sqmm FRLS PVC insulated unsheathed cable up to 1100 V grade conforming to IS - 694 multistranded with copper conductor as earth wire and connecting to common earth dolly for one light /fan point controlled by one switch, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of MS terminal boxes s, laminated cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall deemed to be include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing surface
All as per Sl. Item No. 10.00 here-in-before but for one light point controlled by Two , Two-way switch
All as per Sl. Item No. 10.00 here-in-before but one bell point controlled by one bell push
All as per Sl. Item No. 10.00 here-in-before but One 3 pin socket outlet 5amps point controlled by one switch on the same board with other switches
All as per Sl. Item No. 10.00 here-in-before but One 3 pin socket outlet 5amps point controlled by one switch on independent board
Point wiring complete with stranded copper conductor 4.0Sqmm (nominal area) FRLS PVC insulated unsheathed cable up to 1100 V grade conforming to IS - 694 multistranded drawn through and including rigid 20mm dia PVC medium grade conduit and conduit accessories concealed in walls etc., with sunk type pressed steel terminal boxes made out of 1.6 mm MS sheet duly painted with two coats of red oxide zinc chrome primer with 2.8 mm thick laminated hylam sheet covers for mounting of switches, regulators and also including one run of 4.0 Sqmm FRLS PVC insulated unsheathed cable up to 1100 V grade conforming to IS - 694 multistranded with copper conductor as earth wire and connecting to common earth dolly for 15 Amps independent sockets and AC points complete all as specified and directed.
Batten type for LED T8 Tube light fitting 1x22 Watts 240 volts, including LED Tube rod with driver high efficacy suited for installation in existing T8 fitting incl all accessories pre-wired complete all as specified as directed. Make: Havells cat part No. REGALBATTENT8UPTO1X22WSSBSWH AND tube rod Cat part No. CRYSTAL 1213T8USTL20WLED865SGLASS or equivalent in Phillips/Wipro
3 Star rated LED Type Lamps of 15w complete all as specified and directed. Make: Havells Cat part No. LEDADORE15WB22CDL3STARBALLAMP or equivalent in Phillips/Wipro
Batten type LED tube light fitting 1x10 watts 240 Volts with driver including all accessories pre-wired complete all as specified and directed. Make : Havells Cat Part No. LUMILINEPLUSBS10WLED865SPCSS or equivalent in Philips/Wipro
Sub main wiring complete with 2 runs of 6.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 20mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 6.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6.0 sq.mm copper conductor, one run of 6.0 sq.mm copper earth continuity conductor and one run of 20mm dia conduit shall be measured as one unit length.
Sheet metal enclosure VTPN MCCB DB TPN double door AC type 415 V, 8 way with 200 Amps bus bar, vertical type with MCCB 63 Amps 3 pole 10 KA as incomer flush to wall complete.
Sheet metal enclosure MCB DB TPN double door AC type 415 V, 4 way with 200 Amps bus bar vertical type, flush to wall complete.
Sheet metal enclosure MCB SPN distribution board single pole and neutral 8 ways 240 volts with suitable bus bar with double door complete all as specified and directed.
Sheet metal enclosure MCB SPN distribution board single pole and neutral 4 ways 240 volts with suitable bus bar with double door complete all as specified and directed.
S&F MCB TPN 63 Amps, 10KA 415 volts complete all as specified and directed.
S&F MCBs SPN of 32 Amps, 240 Volts, 10KA complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, 240volts, 10 KA complete all as specifed as specifed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth 4mm, GI earth wire shall be protected by 15mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately.
Ceiling fan brushless DC motor white coloured complete 1200mm sweep with down rod and all accessories energy efficient suitable to function on 230V, single phase AC supply, complete and connecting with and including provision of three core 1.0sqmm cable flexible copper conductor from ceiling rose and requred length of down rod complete all as specified and directed. Make: Havells / Bajaj / Crompton / Philips BEE 5 star rated/ Atomberg
Heavy duty metallic exhaust fan 250mm sweep 240V 50hz 1400RPM single phase AC supply with metal body powder coated with protective steel bird gaurd on wall with all fixing arrangments/ civil work to fix on wall, including provision copper bunched flexible three core 1.5sq.mm PVC insulated cable from ceiling rose to fan complete all as specified and directed. Make: Havells / Bajaj / Crompton / Philips
Supply and fix AC single phase energy meter with backlit LCD display of accuracy class 1.0, 240V, 50Hz, of rating 5-30A and all standard anti tamper features provided with Transparent pilfer proof meter box made of transparent & FR grade engineering plastic available with push fit and hinge type complete all as specified and directed.
Water storage heater / Geyser vertical type, 25 Ltrs capacity 240 volt 50 Hz including BEE 5 star rating, single phase, complete all as specified and directed. Make: Havells / Venus / Racold.
Supply laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cables (heavy duty) 1100 V grade with stranded aluminum conductor of size 185Sqmm 3.5 Core
Supply laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cables (heavy duty) 1100 V grade with stranded aluminum conductor of size 50 Sqmm 3.5 Core
Supply laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored electric power cables (heavy duty) 1100 V grade with stranded aluminum conductor of size 6.0 Sqmm 2 Core complete all as specified and directed.
S&F Energy Saving and environmental friendly long life LED Outdoor Type Bldg Security Light Fitting made up of pressure die cast aluminium housing with high power LED light source and lens embedded PC with IP66 luminaire with PC Housing and opal finish Cover suitable for wet Location of Capacity of 20W fitting including bracket made out of GI pipe of 40mm dia light grade not less than 1.8 mtr long bent to shape, fixed to pole in any position with flat iron clamps of size 50x6 mm complete all as specified and directed complete all as specified. Make: Havells ENDURAPEARLS20WLED757SASYTOPC or equivalent of Phillips, Wipro.
S&F Energy Saving Outdoor Type Security Light Fitting Surface Mounting IP66 luminaire with PC Housing and opal finish Cover suitable for wet Location of Capacity of 25W fitting cable from fitting to junction box and fixing to pole with and including bracket made out of GI pipe of 40mm dia light grade not less than 1.8 mtr long bent to shape, fixed to pole/wall in any position with flat iron clamps of size 50x6 mm complete all as specified and directed. Make: Havells ENDURAPEARLS25WLED757SASYTOPCMP or equivalent of Phillips, Wipro.
Supply and fixing out door type cable juction box non metallic IP 66 on mounted on pole for termination of pole connection incl. 01 Nos MCB 0 to 6 amp capacity and incl. Busbar TP and feed of charge on street light cable termination for next pole complete all as specified and directed.
Supply and fix 3P module DIN timer 24 hours program analog time switch with battery backup 16 Amps with 1 changeover complete all as specified and directed
S&F MCB SP 5 to 32Amps , 230volts, 10 KA complete all as specifed as specifed. Make: HAVELLS/LEGRAND/STANDARD/SCHNEIDR/L&T
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32mm x 6mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and directed. NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately.
CP brass hand shower (health faucet) with 8mm dia , 1.2m long flexible tube and wall hook. (Make : Jaquar Cat No. ALD -573) or its equivalent in Hindware
Cutting the existing water main 50mm dia and insert 'T' reducer/ ferrule for taking branch connection size 50 mm including all materials as required and excavation, earth work complete all as specied and directed.
Brick masonry valve pit 750 X 750 X 750 mm (internal dimension) with Fly ash brick work 230 mm thick walls in CM 1:6, 100 mm tick PCC 1:2:4 type B-1 as in foundation concrete, bed/ floors, coping and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below GL and mixed with water proofing compound @ 2% by weight of cement with and including 40 X 40 X 6 mm angle iron frame 3.15 mm thick MS sheet cover with locking arrangements and one No. 50 mm size 4 leavers MS lock with key in duplicate including excavation and earthwork in soft/loose soil, painting steel surface with two coats black bitumenous paint over a coat of red oxide primer complete all as specified and directed.
Brick masonry valve pit 450 X 450 X 450 mm (internal dimension) with Fly ash brick work 230 mm thick walls in CM 1:4, 100 mm tick PCC 1:2:4 type B-1 as in foundation concrete, bed/ floors, coping and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces, external plaster shall be upto 15 cm below GL and mixed with water proofing compound @ 2% by weight of cement with and including 40 X 40 X 6 mm angle iron frame 2.15 mm thick MS sheet cover with locking arrangements and one No. 50 mm size 4 leavers MS lock with key in duplicate including excavation and earthwork in soft/loose soil, painting steel surface with two coats black bitumenous paint over a coat of red oxide primer complete all as specified and directed.
Surface excavation by manual/mechanical means not exceeding 30cm deep and averaging 15cm deep and getting out in soft / loose soil, complete all as specified and directed
Excavating in trenches by manual/mechanical means, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil, including trimming sides of foundations and forming bottom surface to required level, complete all as specified and directed.
Excavating in trenches by manual/mechanical means, not exceeding 1.5 m wide and exceeding 1.5metre but not exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil, including trimming sides of foundations and forming bottom surface to required level, complete all as specified and directed.
Excavating in trenches by manual/mechanical means, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, including trimming sides of foundations and aforming bottom surface to required level, complete all as specified and directed.
Removing surplus excavated soils by manual/mechanical means to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Removing surplus excavated soils by manual/mechanical means to a distance exceeding 50 metre but not exc 100m and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Removing surplus excavated soils by manual/mechanical means to distance exceeding 250 m but not exceeding 500m and deposting where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
Returning, filling in, in soils, by manual/mechanical means including spreading, levelling, watering and well ramming in layers not exceeding 25cm., complete all as specified and directed.
Excavating over areas by manual/mechanical means not exc 1.50 deep getting out in hard/dense soil complete all as specified and directed.
Excavating over areas by manual/mechanical means not exc 1.50 deep getting out in soft/loose soil complete all as specified and directed.
Rajesh Engineering Consultants
M/s. P S REDDY
Indu Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .