Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC accepted | |
| 2 | L2₹12.7 L+₹74,473.20 (6.23%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹12.7 L+₹77,207.60 (6.46%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹13.2 L+₹1.3 L (10.7%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹13.8 L+₹1.9 L (15.6%)Rejected-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
3 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHUBHAM PRAKASH
GE NORTH UDHAMPUR
GE/U(N)-45/2020-21 SPL REPAIR TO BLDG NO NP-24 (OR SINGLE LIVING ACCN) UNDER AGE B/R-I OF GE NORTH UDHAMPUR
2020_MES_370301_2
GE/U(N)-45/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
class E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹28,000
Yes
12 Oct 2020
12 Sept 2020
5 Oct 2020
12 Sept 2020
3 Oct 2020
19 Sept 2020
60 days
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer -in charge
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour profile of sheet centre to centre n.exc 200mm and height of profile shall not be less than 30mm having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer -in charge
Pre-painted galvalume aluminum zinc coating GI based crimp ridge 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer -in charge
Pre-painted galvalume aluminum zinc coating GI based plain ridge 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer -in charge
Plain Cement Concrete Type C1 1:3:6 (using 12.5 mm graded aggregate) as in roof padding / leveling coarse in between wall and roof sheet, or chamfered on edges finished even and smooth with using extra cement and water proofing compound. ( Water proofing compound shall be measured and paid sepratly )
In repairs second class hard wood clean sawn in scantling in repairs to replace old and decayed timber (including piecing, scarfing,etc., of old and new timber if required) and removing defective portions complete all as specified.
Roof trusses (framed) , trussed , purline, cross gantries and fastening and heavy brakets framing (Beam, tee, angle,channel, hollow sections or flat section ) including distance pieces complete all as specified and directed by Engineer -in charge
Preparation of wood scantling surfaces and applying two coat of creosoting complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
50 mm thick Cement concrete type C-2 , 1:3:6 using 40mm graded aggrigate Finishing surfaces of concrete topping even and fair finishes (without using extra cement) as in plinth protection all as specified and directed by Engr-in- Charge.
75mm thick cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base to receive floor finishes complete all as specified.
Machine cut kota stone slab flooring 18-20mm thick laid over & including 20 mm th cement screed in CM 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer -in charge
ditto as above but as in skirting/dado etc.
15-16 mm thick white or any approval colour marble slab in flooring over cement screed base laid and jointed with white cement slurry mixed to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer -in charge
Factory made , heavy duty vitrified matt finished, paving coloured tiles of size 300x300x10mm thick for external use and including jointing with spacers with neat cement slury and pointed in coloured epoxy tile grout to match the shade of tile laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. Make : Durastone of somany/Pavigres of Kajaria/Endura of Johnson
Providing precast cement concrete kerb stone type B1 1:2:4 (20mm gradded aggregate) of vany section as indicated with plain fair faces including champers, weathering,throating and setting in cement mortar 1:4 complete with joints to match complete all as specified and directed by Engineer -in charge
Preparation of new surface of any description, not otherwise described, over 10 cm width or girth applying two coat of synthetic enamel paint over one coat of cement primer any shade as approved all as directed and specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and recast concrete articles all as specified.
Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) with old size bricks complete all as specified and directed by Engineer -in charge
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer -in charge
Rendering 15 mm thick in cement mortor 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Rendering 10 mm thick in cement mortor 1:6 other than fair faces of brick work or concrete surfaces complete all as specified and as directed.
Supply only integral water proofing compound complete all as specified.
Two coat of cement base paint over a coat of alkali resistant primer incl 1mm thick exterior wall care putty including preparation of newly plastered of wall.complete all as specified and directed by Engineer -in charge
Two coats of oil bound distember over a coat of primer over two coats of approved wall care putty 1mm thick over and including preparation of new plastered surfaces of wall complete all as specified and directed.
Complete removal of existing treatment, preparation of plastered surfaces of wall and applying two coats of cement base paint over one coat of cement primer including 1 mm thick exterior wall care putty ( to be applied in two coats) all as specified. Note: Putty surface shall be rubbed with emery paper to form even and smooth surface.
Complete removal of existing treatment,preparation of surfaces of old wall surfaces and applying two coats of oil bound distember over one 1 mm thick wall care putty complete all as specified.
Taking down Chowkats or frames exc 1.5 Sqm but not exceeding 4 Sq.M each (Without taking off shutters from the frames) complete all as specified and directed
do but n.exc 1.5 Sqm each
Taking down shutters of any descp exc 1 sqm but n.exc 2 sqm complete all as specified and directed by Engineer -in charge
35 mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer -in charge
35 mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges to framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass, etc; sizes of members of shutters as specified in IS-1003, Part-I supplied and fitted to chowkats, complete all as specified and directed by Engineer -in charge.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed by Engr in Charge.
Factory made pressed steel frame steel window/ vent with glazed & gauged shutter (combined with side hung shutters incl box type inges, steel handle, necessary locking arrangement, peg stay complete with one shop coat of zinc chrome primer including PCC (1:3:6) type -0 filling in back side recess profile portion, complete all as specified and directed by Engineer In Charge. Note : Rate quoted are included for wire gauged and glazed window complete & shall be measurred as overall out to out one side only.
3mm Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane all as specified.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint (any colour) over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
M&L for 25 mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer -in charge
300 mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on olt plate and two on staple plate and fixed complete all as specified and directed by Engineer -in charge
150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer -in charge
150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer -in charge
100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engineer -in charge
S&F 250 mm Aluminium alloy,anodised,sliding door bolt with hasp,staple(bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer -in charge
Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed by Engineer -in charge
Small fittings 1st class hard wood such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and directed by Engineer -in charge
Two coat of enamel paint on wooden surfaces over a coal of primer incl preparation of new Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and directed by Engineer -in charge
Dismantling ceiling boards,fibre pulb insulation etc or insulation boards/slabs/blankets,any thickness, including cover and MS Tee grid,all as specified.
False ceiling boards of Fibre Cement Designer tile white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 1220mmx1220mm/1195mmX595mm/1220mmX610mm and any one of the design (occeanic , lake & hill, cascade or electra) fixed with screws over existing metal grid including required cutting/making opening for services like fixed over existing grid inluding necessary scaffolding etc and refixed all exesting electric wiring and fixture all complete at all heights as per direction of Engr-in-charge. Make-Everest/Visakha
Plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in coping/benching, bed plate including necessary form work all as specified and as directed.
Kota stone slab window cills/steps(single piece) incl bull nosing rounding edges directed colour, 18-20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with grey cement shade of slab including grinding and polishing, over 10mm thick rendering in CM 1 :3 complete all as specified and as directed.
In repair MS powder coated pegs set of 5/hanger complete all as specified and directed by Engineer -in charge
Taking down carefully copper/aluminium point wiring, (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. Complete all as specified and directed by Engr-in-Charge.
Point wiring with 1.5sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor medium grade ISI marked drawn into and including PVC concealed conduit with all accessories for one light/fan/bell point controlled by one switch and also including 1.5 Sqmm continuous earth wire connected to common earth dolly complete all as specified and directed.
All as per item No.52 above but for –do—5 pin socket outlet 5 Amps on same board.
All as per item No.52 above but for –do—5 pin socket outlet 5 Amps on independent board.
All as per item No.52 above but for socket outlet 15 Amp with 2.5 Sqmm on independent board incl. 2.5 Sqmm stranded copper conductor earth wire connected to common earth/earth dolly complete.
Supply and fixing of switch piano flush button single pole 5 Amps 230 Volts one way complete all as directed.
Socket out let 2 in 1, 3 pin 5 Amps flush type 230 Volts complete all as directed.
Switch socket combination out let 2 in 1, 6 pin 5 Amp and 15Amp 230 volts complete all as directed.
Electronic type regulator suitable for 1200/1400 mm sweep complete all as directed.
Ceiling rose surface bakelite type 65x50mm three terminals. Complete all as specified and directed by Engr-in-Charge.
Replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 8 Way with IP-43 protections all as specified and directed by Engr-in-Charge.
MCB 6 to 40 Amps SP 240 Volts curve 'C' series. Complete all as specified and directed by Engr-in-Charge.
MCB 20 to 40 Amps SPN 240 Volts curve 'C' series. Complete all as specified and directed by Engr-in-Charge.
Decorative ultra slim linear LED lighting fixture 18/20 watt LED complete making all connection using 1.5 Sqmm copper conductor multistranded PVC insulated twin core flexible cable in white colour from ceiling rose to fitting. Complete all as per directed by Engr-in-charge. Make CROMPTON GREAVES cat part no. LCTL-18-CDL / WIPRO Product Code-D532065 / Havells Ordering Code -LHEXBYPNIN1W020.
New generation energy saving LED bulk head 9/10 Watt with opal diffuser suitable for 600 LUMEN complete. Make Havells cat part no:- LHEXCFP7PN5W010 or equivalent model of WIPRO ordering code DA11265 OR CROMPTON GREAVES cat part No. LBHP-10-CDL.
LED security light fitting Endura Pearl 20 Watt new generation energy saving and environmental friendly, long life, LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07. Including all accessories and connection with suitable cable from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed. Make Havells Cat part No ENDURAPEARLSL20WLED757SASYTOPC, Code- 9405. or wipro cat No. LR02-261-XXX-57-XX or CS ELECTRICA cat part no. LTSF002.
Taking down ceiling fan /exhaust fan complete including overhauling, cleaning with soft solution and painting of the same with white enameled paint including painting of MES number as existing, or rehanging ceiling fan / exhaust fan and connecting up including provision of three core copper conductor cable 1.5 sqmm nominal cross sectional area and length not less than 0.5 mtr from ceiling rose to fan complete all as specified and directed
Taking down carefully old sheet metal enclosure DB,s 8/4 Way including MCB,s including making good the disturbed surface to match with existing surface. Complete all as specified and directed.
Sub main wiring with two run of 4.00 Sqmm (2x4.00 Sqmm) 1100 Volts grade single core FR PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metallic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on surface of walls /roofs / ceiling including cutting chasing and with one run of 4 Sqmm (1x4 Sqmm ) single core FR PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed.
Earthing in repair complete with galvanized steel earth electrode 60cmX60cmx6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5m below normal ground level connected to earth lead by means of bolts nuts and washers of GI steel and including earthing pit charcoal, common salt, GI 4.0mm dia lead wire 20mm GI medium grade watering pipe 15mm bore light grade protection pipe 5 Mtr length with wire mesh and funnel PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, angle iron frame and RCC cover and earth work complete all as shown in electrical plate No.3 of SSR -2009(Part-1).complete all as specified and directed by Engineer -in charge
Supply laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armounded electric power cables (heavy duty) 1100 Volts conductor of size 25 Sqmm 2 core including taking down the existing cable completed all as directed.
Excavating in trenches in any type of soil n exc 1.5 m wide and n exc 1.5 m in depth for laying of under ground cable, electric pole and getting out complete all as directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer -in charge.
Removing excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer -in charge.
Sand cushioning to under ground cable with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying all as specified
Supply and lay brick class B covering as mechanical protection to cable with well burnt all as specified.
GI tubing light grade with all fittings and fixed in wall and floor or fixed to pole of size 40 mm dia. Complete all as specified and directed.
devraj chalotra
KUMAR CONSTRUCTION CO
takashdeep traders
TULSI RAINA AND SONS
KALSOTRA CONSTRUCTION CO
s l sharma and sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .