Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC | ₹45.4 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹51.0 L+₹5.6 L (12.3%)Rejected-AOC C 299 MODEL TOWN MANDI ADAMPUR HISAR HARYANA 125052 | HISAR | HARYANA | 125052 | ₹51.0 L+₹5.6 L (12.3%) | L2 | Rejected-AOC HIGHEST |
| 3 | L3₹51.7 L+₹6.3 L (13.9%)Rejected-AOC HOUSE NO 42 AGGARSAIN COLONY HISAR 125001 | HISAR | HARYANA | 125001 | ₹51.7 L+₹6.3 L (13.9%) | L3 | Rejected-AOC HIGHEST |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹53.9 L
EMD Value
₹1.1 L
Closing Date
16 Feb 2023, 5:00 pmClosed
SH SANDEEP KUMAR
Municipal Corporation Hisar
Const. of 6 Bus Queue Shelters Rajgarh road Hisar MC Hisar
2023_HRY_254031_1
202317D9BE20 82C8 4765 92C3 F12B521CE789289ULB
Open Tender
Civil Works
Works
180 days
Hisar
2 documents required · 2 mandatory
₹3,500
Yes
₹1.1 L
Yes
18 Apr 2023
16 Jan 2023
17 Feb 2023
16 Jan 2023
16 Feb 2023
16 Jan 2023
Amount
P/F mefium grade MS Junction boxes in cast in situ fundation beam of 150x150 mm size
Providing and fixing heavy duty SS prefabricated dust bins with canopy and two point support grouted in cement mortar and finished as per floor finish.
Providing and fixing MS Electrical weather proof leader box approximately 600mm wide and 900mm high as required for installing MCB switch gear and meters as required for advertisement and other electrical gear, with provision for inserting cable conduits as per design. The access to feeder box shall be through a toll based (common for all locks. provided in each package) key. Tools should not be identical for different package shelters
Vandal resistant light source of polycarbonate body with compact fluorescent lamp of white NS colour of 55w of approved make with IP 67 approval, including cable fixing, switchgear etc. all complete.
Providing and fixing 5-walled, 10mm thick polycarbonate multiwall sheet bronze colour having a light transmission of 37% with a U- value of 2.39 w/m2 K.Lexan thermoclear multiwall sheet LT2UV105R175 from SABIC innovative plastics or Equivalent. Fixing of the 10mm sheet to be done with profiles having EPDM / silicon. Aluminum profiles need to be used and front and rear of polycarbonate sheet has to be closed by aluminum profile.
Providing and fixing anodized aluminum 25 x 50mm channel frame with 40W standard manufactured tube light fittings with electronic choke starters and wiring all complete connection to electrical supply drom feeder box with minimum 4 tubelights x per square meter (of add panel size) or actual requirement decided by the engineer in charge. The tube light frame and fittings (including that in feeder pillar) should includeballast ELCB timer MCB mounting blocks etc. The tube light alignment should allow two way lighting (front and back) of add panel
Providing and pasting at site high grade printed vinyl with bus shelter name logo, route number etc. on one sides of the front facia information board. The vinyl shall be minimum 85 micron thick, of LG or equivalent make complete in all respect and to the entire satisfaction of engineer-in-charge.
Supplying and fixing of double sided aluminum frame signage made of 6063-T5 aluminum frame with section weight 5.3 to 5.5kg/m with minimum tensile strength 22000 psl as per drawing provided having 4mm clear solid compact polycarbonate on both side and reinforced with internal support frame, completely sealed with the help of silicon and EPDM to make it dust and water proof. Should have the inbuilt strong clipping and frame arrangement for holding the flex of digital media alongwith all necessary cleats and corner joinery required to build the signage with sufficient strength. The aluminum frame should have strong locking arrangement which can resist theft. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron, signage should have inbuilt arrangement of mounting it with the bus shelter structure. The enclosure should provide weather proof protection required for the signage to operate outdoors, having inbuilt ventilation systems. (measurements for double sided signage to be taken for both sides during
Supplying and fixing single sided aluminum frame signage made of 6063-T5 aluminum frame with section weight 3.80 to 4.00kg/m with minimum tensile strength 22000 psl as per drawing provided having 4mm clear solid compact polycarbonate in front and 3mm ACP sheet reinforced with internal support frame at rear completely sealed with the of silicon and EPDM to make it dust and water proof should have the inbuilt strong clipping and frame arrangement for holding the flex or digital imedia alongwith all necessary cleats and corner joinery required to build thus signage with sufficient strength. The aluminum frame should have strong locking arrangement which can resist theft. The aluminum frame should have polyester powder coating with minimum thickness of 60 micron. Signage should have inbullt arrangement of mounting it with the bus shelter structure. The enclosure should provide weather proof protection required for the signage to operate outdoors, having inbuilt ventilation systems.
Bidder Name
Amount
Raghunath Rai Contractor(GSTN-NA)
M/S KHATTU INTERNATIONAL(GSTN-NA)
VARUN BANSAL(GSTN-NA)
Raghunath Rai Contractor
M/S KHATTU INTERNATIONAL
Raghunath Rai Contractor
VARUN BANSAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .